The PRECISION II Study: Evaluating the Accuracy of the LabPatch Glucose Sensing System

NCT ID: NCT05754281

Last Updated: 2025-09-05

Study Results

Results pending

The study team has not published outcome measurements, participant flow, or safety data for this trial yet. Check back later for updates.

Basic Information

Get a concise snapshot of the trial, including recruitment status, study phase, enrollment targets, and key timeline milestones.

Recruitment Status

RECRUITING

Total Enrollment

60 participants

Study Classification

OBSERVATIONAL

Study Start Date

2023-02-03

Study Completion Date

2026-12-31

Brief Summary

Review the sponsor-provided synopsis that highlights what the study is about and why it is being conducted.

The purpose of this study is to evaluate the accuracy of the Cambridge Medical Technologies, LLC second generation (2nd Gen) LabPatch glucose sensing system compared to a laboratory glucose analyzer (YSI 2300 STAT Plus) and 2 commercial glucometers, OneTouch Verio and Freestyle Lite. The primary endpoint of this study is the mean absolute relative difference (MARD) for 2nd Gen LabPatch system compared to each of the above mentioned glucose references over a 6 hour outpatient visit.

Detailed Description

Dive into the extended narrative that explains the scientific background, objectives, and procedures in greater depth.

In a pilot study conducted previously by our group using the prototype 1st generation LabPatch system (PRECISION study, 2016-31), the investigators found that LabPatch glucose measurements strongly correlated with those of YSI, OneTouch Verio, and Freestyle lite in a sample of 30 subjects. However, the investigators observed significant inter- and intra-subject variability of LabPatch glucose measurements. Factors that may have contributed to this variability include: manual manufacturing of the 1st Gen LabPatch circuit chips and/or variability in the pressure applied by subjects on the circuit chip at each measurement. To control for these variables with the goal of improving overall accuracy, Cambridge Medical Technologies, LLC significantly improved and completely automated the manufacturing process of the circuit chips. In addition, the system has been miniaturized to a more user-friendly layout and with a clasp unit to control for pressure applied by the subject finger on the circuit chip.

The 2nd Gen LabPatch system consists of:

I. The 2nd Gen LabPatch chip which lies in the center of a clasp unit. The chip measures approximately 15.7 mm \[0.618"\] x 15.7 mm \[0.618"\]. The chip has a telescopic micropipette which draws interstitial fluid to be analyzed for glucose levels. The chip is also able to measure skin temperature to ensure appropriate skin contact II. A LabPatch clasp device III. A wire that connects the clasp unit to a Windows tablet which will communicate with the clasp via an application. Each data point will be viewed on the tablet and the application will also have some limited graphing capabilities to view trends of previous measurements The system has been previously tested on 10 human subjects with type 1 diabetes, each for six hours, at the Georgetown University Medical Center under clinical conditions supervised by a medical team including an endocrinologist and dermatologist. The test confirmed the absence of pain or abnormal physical sensation and that the operation of the device causes no tissue damage,instigates no neural sensation for the subject, and leaves no blemish on the skin. No skin damage incurred by the LabPatch operation was detected.

The 2nd Gen LabPatch system is an in vitro diagnostic device (IVD), does not have significant risk and is therefore exempted from the IDE requirements. In addition, the device uses an in vitro diagnostic technology that does not create adverse events and therefore a data safety monitoring board (DSMB) is not requited.

Conditions

See the medical conditions and disease areas that this research is targeting or investigating.

Type 1 Diabetes Mellitus Type 2 Diabetes Mellitus

Study Design

Understand how the trial is structured, including allocation methods, masking strategies, primary purpose, and other design elements.

Observational Model Type

COHORT

Study Time Perspective

CROSS_SECTIONAL

Study Groups

Review each arm or cohort in the study, along with the interventions and objectives associated with them.

Study Cohort

60 adult subjects with type 1 or type 2 diabetes treated with insulin. The accuracy of the 2nd Gen LabPatch Continuous Glucose Sensing will be evaluated during the study visit, comparing to YSI 2300 STAT Plus, OneTouch Verio and FreeStyle Lite.

2nd Gen LabPatch Glucose Sensing System

Intervention Type DEVICE

I. The 2nd Gen LabPatch chip which lies in the center of a clasp unit. The chip measures approximately 15.7 mm \[0.618"\] x 15.7 mm \[0.618"\]. The chip has a telescopic micropipette which draws interstitial fluid to be analyzed for glucose levels. The chip is also able to measure skin temperature to ensure appropriate skin contact

II. A LabPatch clasp device

III. A wire that connects the clasp unit to a Windows tablet which will communicate with the clasp via an application. Each data point will be viewed on the tablet and the application will also have some limited graphing capabilities to view trends of previous measurements

Interventions

Learn about the drugs, procedures, or behavioral strategies being tested and how they are applied within this trial.

2nd Gen LabPatch Glucose Sensing System

I. The 2nd Gen LabPatch chip which lies in the center of a clasp unit. The chip measures approximately 15.7 mm \[0.618"\] x 15.7 mm \[0.618"\]. The chip has a telescopic micropipette which draws interstitial fluid to be analyzed for glucose levels. The chip is also able to measure skin temperature to ensure appropriate skin contact

II. A LabPatch clasp device

III. A wire that connects the clasp unit to a Windows tablet which will communicate with the clasp via an application. Each data point will be viewed on the tablet and the application will also have some limited graphing capabilities to view trends of previous measurements

Intervention Type DEVICE

Eligibility Criteria

Check the participation requirements, including inclusion and exclusion rules, age limits, and whether healthy volunteers are accepted.

Inclusion Criteria

1. Subject has voluntarily signed and dated an informed consent form, approved by an Institutional Review Board/Independent Ethics Committee, and provided Health Insurance Portability and Accountability Act authorization (HIPAA) or other privacy authorization prior to any participation in study.
2. Subject is between 18 and 75 years of age.
3. Subject is diagnosed with type 1 diabetes or type 2 diabetes for ≥3 months and is being treated with insulin injections in the form of multiple daily injections or through insulin infusion pump.
4. Subject is a male or a non-pregnant and non-lactating female, at least 6 weeks postpartum prior to screening visit. A urine pregnancy test is required for all female subjects unless she is not of childbearing potential, defined as postmenopausal for at least one year prior to screening visit or surgically sterile (bilateral tubal ligation, bilateral oophorectomy, or hysterectomy).

Exclusion Criteria

1. Subject is pregnant or lactating.
2. Subject is not treated with insulin.
3. Subject has/had acute or chronic, contagious, infectious disease
4. Subjects with history of blood-born chronic viral infection (e.g. Hepatitis C and HIV)
5. Subject has/had clotting or bleeding disorders or other hematological disease.
6. Subject has an active malignancy (excluding the following dermal malignancies: basal cell carcinoma, squamous cell carcinoma, carcinoma in-situ of the cervix).
7. Subject had a recent cardiovascular event (e.g., myocardial infarction, stroke) ≤ six months prior to screening visit; or stated history of congestive heart failure.
Minimum Eligible Age

18 Years

Maximum Eligible Age

75 Years

Eligible Sex

ALL

Accepts Healthy Volunteers

No

Sponsors

Meet the organizations funding or collaborating on the study and learn about their roles.

Cambridge Medical Technologies, LLC

INDUSTRY

Sponsor Role collaborator

Joslin Diabetes Center

OTHER

Sponsor Role lead

Responsible Party

Identify the individual or organization who holds primary responsibility for the study information submitted to regulators.

Responsibility Role SPONSOR

Locations

Explore where the study is taking place and check the recruitment status at each participating site.

Joslin Diabetes Center

Boston, Massachusetts, United States

Site Status RECRUITING

Countries

Review the countries where the study has at least one active or historical site.

United States

Facility Contacts

Find local site contact details for specific facilities participating in the trial.

Jaime Jacob, BA

Role: primary

6173094152

Abd Almasih Barbar Askar, MD

Role: backup

6173094157

Other Identifiers

Review additional registry numbers or institutional identifiers associated with this trial.

STUDY00000130

Identifier Type: -

Identifier Source: org_study_id

More Related Trials

Additional clinical trials that may be relevant based on similarity analysis.

Simplified Onboarding in Adults With Type 2 Diabetes
NCT07070830 ACTIVE_NOT_RECRUITING NA
Accuracy Characterization Study
NCT01932944 COMPLETED