Volar Carbon Plate Effects on Procedure Time

NCT ID: NCT05630430

Last Updated: 2024-05-30

Study Results

Results pending

The study team has not published outcome measurements, participant flow, or safety data for this trial yet. Check back later for updates.

Basic Information

Get a concise snapshot of the trial, including recruitment status, study phase, enrollment targets, and key timeline milestones.

Recruitment Status

COMPLETED

Clinical Phase

NA

Total Enrollment

42 participants

Study Classification

INTERVENTIONAL

Study Start Date

2021-04-01

Study Completion Date

2024-05-28

Brief Summary

Review the sponsor-provided synopsis that highlights what the study is about and why it is being conducted.

Radius distal end fractures are common orthopedic injuries. Many methods have been described in the treatment of distal radius fractures. The fixation of radius distal end fracture with volar plate was first applied by Ellis in 1965. Over the years, ideas have been put forward on the materials used for plates and the radiolucent carbon fiber plates has been used. These plates cause less artifact in computed tomography (CT) and magnetic resonance examinations (MRI), allow a better evaluation of the fracture, exhibit biomechanical characteristics close to the cortical bone, and do not cause a coldwedding in patients.

Detailed Description

Dive into the extended narrative that explains the scientific background, objectives, and procedures in greater depth.

Titanium alloy plates are frequently used materials in our current orthopedic surgery practices. The main goal during surgical treatment is to obtain an accurate and acceptable bone alignment. Achieving this goal as soon as possible will reduce additional morbidity and mortality and increase the success of treatment. Therefore, studies aiming to reduce the operation time come to the fore. When the literature is examined, there are limited number of studies on carbon plates. In these studies, it was reported that similar functional results were obtained with titanium alloy plates. Although the bones are at the surgeon's disposal in plate fixation of radius distal end fractures, fluoroscopy is frequently used for reduction control. The increase in the need for scopy both directly affects the duration of the operation and causes the surgical team to be exposed to excessive radiation. Since titanium alloy plates are radiopaque, they create a superposition to the fracture line and more than one view is usually required in each plane to ensure the reduction quality during surgery. Carbon alloy plates, on the other hand, offer the advantage of faster radiological reduction control because they do not create superposition to the fracture line. In our study, in addition to the comparisons in the literature, it is aimed to investigate the effect of carbon plates on the procedure time. For this purpose, distal radius fractured patients applied to our clinic will be treated with titanium and carbon plates after the necessary randomization. After the tourniquet is applied, the time elapsed until the fixation is completed, the duration of scopy, and the number of scopy images taken will be recorded. In the follow-ups, the functional scores and radiological measurements of the patients will be made and the complications will be evaluated.

Conditions

See the medical conditions and disease areas that this research is targeting or investigating.

Radiation Exposure Surgery Radius Distal Fracture

Study Design

Understand how the trial is structured, including allocation methods, masking strategies, primary purpose, and other design elements.

Allocation Method

RANDOMIZED

Intervention Model

PARALLEL

Primary Study Purpose

TREATMENT

Blinding Strategy

SINGLE

Investigators

Study Groups

Review each arm or cohort in the study, along with the interventions and objectives associated with them.

Volar Carbon Plate Effects on Procedure Time

Carbon alloy plates, offer the advantage of faster radiological reduction control because they do not create superposition to the fracture line

Group Type EXPERIMENTAL

The Effect of Volar Carbon Plate Applications on Radiation Exposure and Procedure Time in Intra-articular Radius Distal End Fractures

Intervention Type PROCEDURE

Surgery procedure, Although the bones are at the surgeon's disposal in plate fixation of radius distal end fractures, fluoroscopy is frequently used for reduction control. The increase in the need for scopy both directly affects the duration of the operation and causes the surgical team to be exposed to excessive radiation. Since titanium alloy plates are radiopaque, they create a superposition to the fracture line and more than one view is usually required in each plane to ensure the reduction quality during surgery. Carbon alloy plates, on the other hand, offer the advantage of faster radiological reduction control because they do not create superposition to the fracture line. In our study, in addition to the comparisons in the literature, it is aimed to investigate the effect of carbon plates on the procedure time. surgery time and exposure of radiation will be recorded at the end of the surgery

Titanium Alloy Plates Group

Titanium alloy plates are frequently used materials in our current orthopedic surgery practices. The main goal during surgical treatment is to obtain an accurate and acceptable bone alignment. Since titanium alloy plates are radiopaque, they create a superposition to the fracture line and more than one view is usually required in each plane to ensure the reduction quality during surgery.

Group Type ACTIVE_COMPARATOR

The Effect of Volar Carbon Plate Applications on Radiation Exposure and Procedure Time in Intra-articular Radius Distal End Fractures

Intervention Type PROCEDURE

Surgery procedure, Although the bones are at the surgeon's disposal in plate fixation of radius distal end fractures, fluoroscopy is frequently used for reduction control. The increase in the need for scopy both directly affects the duration of the operation and causes the surgical team to be exposed to excessive radiation. Since titanium alloy plates are radiopaque, they create a superposition to the fracture line and more than one view is usually required in each plane to ensure the reduction quality during surgery. Carbon alloy plates, on the other hand, offer the advantage of faster radiological reduction control because they do not create superposition to the fracture line. In our study, in addition to the comparisons in the literature, it is aimed to investigate the effect of carbon plates on the procedure time. surgery time and exposure of radiation will be recorded at the end of the surgery

Interventions

Learn about the drugs, procedures, or behavioral strategies being tested and how they are applied within this trial.

The Effect of Volar Carbon Plate Applications on Radiation Exposure and Procedure Time in Intra-articular Radius Distal End Fractures

Surgery procedure, Although the bones are at the surgeon's disposal in plate fixation of radius distal end fractures, fluoroscopy is frequently used for reduction control. The increase in the need for scopy both directly affects the duration of the operation and causes the surgical team to be exposed to excessive radiation. Since titanium alloy plates are radiopaque, they create a superposition to the fracture line and more than one view is usually required in each plane to ensure the reduction quality during surgery. Carbon alloy plates, on the other hand, offer the advantage of faster radiological reduction control because they do not create superposition to the fracture line. In our study, in addition to the comparisons in the literature, it is aimed to investigate the effect of carbon plates on the procedure time. surgery time and exposure of radiation will be recorded at the end of the surgery

Intervention Type PROCEDURE

Other Intervention Names

Discover alternative or legacy names that may be used to describe the listed interventions across different sources.

Titanium Alloy Plate surgery Carbon Alloy Plate surgery

Eligibility Criteria

Check the participation requirements, including inclusion and exclusion rules, age limits, and whether healthy volunteers are accepted.

Inclusion Criteria

* Radius distal simple intraarticular fractures
* Closed fractures

Exclusion Criteria

* Acompanying fracture at the same limb
* Open fractures
* Pathological fractures
* The patients who don't want to be included in the study
Minimum Eligible Age

18 Years

Eligible Sex

ALL

Accepts Healthy Volunteers

No

Sponsors

Meet the organizations funding or collaborating on the study and learn about their roles.

Ataturk University

OTHER

Sponsor Role lead

Responsible Party

Identify the individual or organization who holds primary responsibility for the study information submitted to regulators.

Muhammed Cagatay Engin

Principal Investigator

Responsibility Role PRINCIPAL_INVESTIGATOR

Locations

Explore where the study is taking place and check the recruitment status at each participating site.

Ataturk University

Erzurum, , Turkey (Türkiye)

Site Status

Countries

Review the countries where the study has at least one active or historical site.

Turkey (Türkiye)

Other Identifiers

Review additional registry numbers or institutional identifiers associated with this trial.

1

Identifier Type: -

Identifier Source: org_study_id

More Related Trials

Additional clinical trials that may be relevant based on similarity analysis.