Portable Artificial Pancreas Applied for Youth and Adolescents

NCT ID: NCT05543850

Last Updated: 2023-08-14

Study Results

Results pending

The study team has not published outcome measurements, participant flow, or safety data for this trial yet. Check back later for updates.

Basic Information

Get a concise snapshot of the trial, including recruitment status, study phase, enrollment targets, and key timeline milestones.

Recruitment Status

COMPLETED

Clinical Phase

NA

Total Enrollment

20 participants

Study Classification

INTERVENTIONAL

Study Start Date

2022-10-28

Study Completion Date

2023-05-19

Brief Summary

Review the sponsor-provided synopsis that highlights what the study is about and why it is being conducted.

The purpose of this study is to determine the performance of a bi-hormonal reactive closed-loop system in adolscents with type 1 diabetes mellitus. The percentage of time spent in the target range (3.9-10.0 mmol/L) is the main outcome and will be compared between the bi-hormonal closed-loop system and the current treatment of the patients. Also, safety parameters, pharmacodynamics and patient reported outcomes (expectations, trust and treatment satisfaction scores) are compared.

This study is a monocenter, randomized, cross-over trial with 20 subjects. The subjects will be randomized to receive either the open-loop therapy or the closed-loop therapy for the first two-week study period and switch to the alternate treatment with at least two weeks in between.

Detailed Description

Dive into the extended narrative that explains the scientific background, objectives, and procedures in greater depth.

Background of the study:

Inreda Diabetic B.V. (Goor, The Netherlands) developed a bi-hormonal reactive closed loop system to automate glucose regulation (artificial pancreas; AP) in patients with diabetes mellitus type 1. In previous studies, we tested the performance and safety of this bi-hormonal closed-loop system in an outpatient setting in patients with type 1 diabetes mellitus (T1DM) for a duration up to 2 weeks, leading to CE-marking of the system. The device is currently intended for insulin-dependent adult patients with diabetes. However, there is great need to improve glycaemic control in youth and adolescents with diabetes.

Objective of the study:

The main objective of this study is to determine the performance of the closed-loop system in adolescents with T1DM. Secondary objectives include: to assess the safety of the closed-loop system; to determine the time that the closed-loop algorithm is active; and to assess expectations and treatment satisfaction of the closed-loop system.

Study design:

This study is a monocenter randomized cross-over trial.

Study population:

The study population will comprise 20 patients with T1DM, between 12 and 18 years old, not having impaired awareness of hypoglycaemia, and who are treated with insulin therapy for at least 6 months. Patients receiving treatment with multiple daily injections (MDI) or continuous subcutaneous insulin injections (CSII), and in addition glucose monitoring using self-monitored blood glucose (SMBG), flash glucose monitoring (FGM) or continuous glucose monitoring (CGM) are included into the study.

Intervention:

The intervention includes 2 weeks of closed-loop control with the artificial pancreas (AP) of Inreda Diabetic. The device uses 2 subcutaneous glucose sensors, 2 subcutaneous infusion sets, and incorporates 2 pumps and a reactive closed-loop algorithm. During 4-6 days before the intervention the patients receive training on the use of the closed-loop system and will start using the device under close supervision. The control arm (open loop treatment) consists of the patient's standard therapy at home for 2 weeks.

Main study parameters/endpoints:

Main study parameter is the percentage of time spent in the target range (3.9-10.0 mmol/L), which will be compared between the open and closed-loop periods for each patient.

Conditions

See the medical conditions and disease areas that this research is targeting or investigating.

Diabetes Mellitus, Type 1

Study Design

Understand how the trial is structured, including allocation methods, masking strategies, primary purpose, and other design elements.

Allocation Method

RANDOMIZED

Intervention Model

CROSSOVER

The study is a monocenter, randomized cross-over trial. The total duration of the study will be three months: two weeks open loop control and 4-6 training days followed by a two-week closed-loop period, or vice versa, with at least 2 weeks in between.
Primary Study Purpose

TREATMENT

Blinding Strategy

NONE

Study Groups

Review each arm or cohort in the study, along with the interventions and objectives associated with them.

Open loop control

In this arm, the patients will use their usual diabetes therapy. Additionally, patients will wear a blinded DexcomG6 for data collection during the open loop period.

Group Type ACTIVE_COMPARATOR

Open-loop control

Intervention Type DEVICE

During open-loop control the patients will use their usual diabetes therapy. Aditionally, patients will wear a blinded Dexcom G6 for data collection during the open loop period.

Bi-hormonal closed-loop control

In this arm, treatment consists of the bi-hormonal closed-loop system. A short acting insulin analogue (Humalog, 3 ml pre-filled cartridge, Eli Lilly) and glucagon (Glucagen, Novo Nordisk; 3.15 ml cartridge Accu-Chek Spirit, Roche) will be administered according to the closed-loop algorithm. Additionally, patients will wear a blinded DexcomG6 for data collection during the closed loop period.

Group Type EXPERIMENTAL

Bi-hormonal closed-loop control

Intervention Type DEVICE

During bi-hormonal closed-loop control insulin and glucagon are administered to the developed closed-loop algorithm. Aditionally, patients will wear a blinded Dexcom G6 for data collection during the closed loop period.

Interventions

Learn about the drugs, procedures, or behavioral strategies being tested and how they are applied within this trial.

Bi-hormonal closed-loop control

During bi-hormonal closed-loop control insulin and glucagon are administered to the developed closed-loop algorithm. Aditionally, patients will wear a blinded Dexcom G6 for data collection during the closed loop period.

Intervention Type DEVICE

Open-loop control

During open-loop control the patients will use their usual diabetes therapy. Aditionally, patients will wear a blinded Dexcom G6 for data collection during the open loop period.

Intervention Type DEVICE

Other Intervention Names

Discover alternative or legacy names that may be used to describe the listed interventions across different sources.

Artificial Pancreas (AP) bi-hormonal AP system AP5

Eligibility Criteria

Check the participation requirements, including inclusion and exclusion rules, age limits, and whether healthy volunteers are accepted.

Inclusion Criteria

* Diagnosed with type 1 diabetes mellitus
* Twelve to eighteen years old;
* Treated with insulin therapy for at least 6 months;
* Willing and able to sign informed consent or to assent to study participation.

Exclusion Criteria

* Impaired awareness of hypoglycaemia (score ≥ 4) according to Gold and/or Clarke questionnaire\[6,7\];
* BMI ≥ 35 kg/m2;
* Pregnancy and/or breastfeeding;
* HbA1c \> 97 mmol/mol (11.0%);
* Use of acetaminophen (paracetamol) during the open loop or closed-loop period,as this may influence the sensor glucose measurements;
* Limited ability to see, hear or feel the alarm signals of the closed-loop system;
* Unwillingness to act in response to the alarm signals;
* Living alone during the night during the closed-loop period (the patient may ask someone to stay over temporarily);
* Expected poor internet connectivity regarding 24/7 tele monitoring;
* Any condition that the local investigator feels would interfere with trial participation or evaluation of the results.
Minimum Eligible Age

12 Years

Maximum Eligible Age

18 Years

Eligible Sex

ALL

Accepts Healthy Volunteers

No

Sponsors

Meet the organizations funding or collaborating on the study and learn about their roles.

Stichting Robopump

UNKNOWN

Sponsor Role collaborator

Rijnstate ziekenhuis

UNKNOWN

Sponsor Role collaborator

Kinder Diabetes Centrum Nijmegen

UNKNOWN

Sponsor Role collaborator

Inreda Diabetic B.V.

INDUSTRY

Sponsor Role lead

Responsible Party

Identify the individual or organization who holds primary responsibility for the study information submitted to regulators.

Responsibility Role SPONSOR

Principal Investigators

Learn about the lead researchers overseeing the trial and their institutional affiliations.

Arianne Bon, MD, PhD

Role: PRINCIPAL_INVESTIGATOR

Rijnstate ziekenhuis

Locations

Explore where the study is taking place and check the recruitment status at each participating site.

Rijnstate Ziekenhuis

Arnhem, Gelderland, Netherlands

Site Status

Countries

Review the countries where the study has at least one active or historical site.

Netherlands

Other Identifiers

Review additional registry numbers or institutional identifiers associated with this trial.

NL79829.000.22

Identifier Type: -

Identifier Source: org_study_id

More Related Trials

Additional clinical trials that may be relevant based on similarity analysis.

Closed Loop Context Aware AID
NCT06676657 RECRUITING NA
Closed Loop From Onset in Type 1 Diabetes
NCT02871089 ACTIVE_NOT_RECRUITING NA