Safety and Efficacy of Artificial Pancreas With and Without a Meal Detection Module on Glycemic Control in Adolescents With Type 1 Diabetes After a Missed Bolus
NCT ID: NCT02909829
Last Updated: 2020-05-27
Study Results
The study team has not published outcome measurements, participant flow, or safety data for this trial yet. Check back later for updates.
Basic Information
Get a concise snapshot of the trial, including recruitment status, study phase, enrollment targets, and key timeline milestones.
COMPLETED
NA
12 participants
INTERVENTIONAL
2017-10-31
2019-10-11
Brief Summary
Review the sponsor-provided synopsis that highlights what the study is about and why it is being conducted.
The aim of this study is to assess the safety and efficacy of a closed-loop delivery with and without meal detection module compared to conventional pump therapy in regulating post-prandial glycemic levels after omission of a meal bolus.
The primary hypothesis is that closed-loop delivery with no meal detection module will reduce the mean increase in postprandial glucose levels after a missed bolus compared to conventional pump therapy.
Related Clinical Trials
Explore similar clinical trials based on study characteristics and research focus.
Closed-loop Control of Glucose Levels (Artificial Pancreas) for 24 Hours in Adults and Adolescents With Type 1 Diabetes
NCT01754337
Closed-loop Control of Postprandial Glucose Levels in Children and Adults With Type 1 Diabetes
NCT02490098
Closed-loop Control of Glucose Levels (Artificial Pancreas) for 5 Days in Adults With Type 1 Diabetes
NCT02488616
Closed-loop Control of Overnight Glucose Levels (Artificial Pancreas) in Children With Type 1 Diabetes in a Diabetes Camp
NCT02189694
Closed-loop Control of Glucose Levels (Artificial Pancreas) for 15 Weeks in Adolescents and Adults With Type 1 Diabetes
NCT02846857
Detailed Description
Dive into the extended narrative that explains the scientific background, objectives, and procedures in greater depth.
The aim of this study is to conduct a randomized, three-way, cross-over trial to compare the efficacy of closed-loop delivery, closed-loop delivery with a meal detection module, and conventional pump therapy. The study aims to compare these three interventions for 9 hours in adolescents with poorly controlled type 1 diabetes.
Each 9 hours will include two meals of different carbohydrate content, of which one will not have a carbohydrate-matched prandial bolus. This study will allow for the assessment of the safety and efficacy of closed-loop delivery with and without a meal detection module compared to conventional pump therapy in regulating post-prandial glycaemia.
The aim of this study is to assess the safety and efficacy of a closed-loop delivery with and without meal detection module compared to conventional pump therapy in regulating post-prandial glycemic levels after omission of a meal bolus.
The primary hypothesis is that closed-loop delivery with no meal detection module will reduce the mean increase in postprandial glucose levels after a missed bolus compared to conventional pump therapy.
The secondary hypotheses are:
1. Closed-loop delivery with meal detection module will reduce the mean increase in postprandial glucose levels after a missed bolus compared to conventional pump therapy.
2. Closed-loop delivery with meal detection module will reduce the mean increase in postprandial glucose levels after a missed bolus compared to closed-loop delivery with no meal detection module.
Conditions
See the medical conditions and disease areas that this research is targeting or investigating.
Study Design
Understand how the trial is structured, including allocation methods, masking strategies, primary purpose, and other design elements.
RANDOMIZED
CROSSOVER
TREATMENT
NONE
Study Groups
Review each arm or cohort in the study, along with the interventions and objectives associated with them.
Closed Loop Delivery
Insulin will be delivered by subcutaneous insulin infusion pump. Infusion rates will be changed manually every 10 minutes based on the computer generated recommendation infusion rates, calculated from the glucose levels measured by a real time sensor. The computer generated recommendations are based on a predictive algorithm. Participants will eat breakfast and bolus, then eat lunch and not bolus.
Closed Loop Delivery
Insulin will be delivered by subcutaneous insulin infusion pump. Infusion rates will be changed manually every 10 minutes based on the computer generated recommendation infusion rates, calculated from the glucose levels measured by a real time sensor. The computer generated recommendations are based on a predictive algorithm.
Closed Loop Delivery with Meal Detection Module
Insulin will be delivered by subcutaneous insulin infusion pump. Infusion rates will be changed manually every 10 minutes based on the computer generated recommendation infusion rates, calculated from the glucose levels measured by a real time sensor. The computer generated recommendations are based on a predictive algorithm with an overlying meal detection module which detects missed meals and will increase insulin infusion rates based on a predictive meal detection algorithm. Participants will eat breakfast and bolus, then eat lunch and not bolus.
Closed Loop Delivery with Meal Detection Module
Closed Loop Delivery with Meal Detection Module Insulin will be delivered by subcutaneous insulin infusion pump. Infusion rates will be changed manually every 10 minutes based on the computer generated recommendation infusion rates, calculated from the glucose levels measured by a real time sensor. The computer generated recommendations are based on a predictive algorithm with an overlying meal detection module which detects missed meals and will increase insulin infusion rates based on a predictive meal detection algorithm
Conventional Pump Therapy
Insulin will be delivered by subcutaneous insulin infusion pump with participants usual infusion rate. Participants will eat breakfast and bolus as per usual, then eat lunch and not bolus.
Conventional Pump Therapy
Insulin will be delivered by subcutaneous insulin infusion pump with participants usual infusion rate
Interventions
Learn about the drugs, procedures, or behavioral strategies being tested and how they are applied within this trial.
Closed Loop Delivery
Insulin will be delivered by subcutaneous insulin infusion pump. Infusion rates will be changed manually every 10 minutes based on the computer generated recommendation infusion rates, calculated from the glucose levels measured by a real time sensor. The computer generated recommendations are based on a predictive algorithm.
Closed Loop Delivery with Meal Detection Module
Closed Loop Delivery with Meal Detection Module Insulin will be delivered by subcutaneous insulin infusion pump. Infusion rates will be changed manually every 10 minutes based on the computer generated recommendation infusion rates, calculated from the glucose levels measured by a real time sensor. The computer generated recommendations are based on a predictive algorithm with an overlying meal detection module which detects missed meals and will increase insulin infusion rates based on a predictive meal detection algorithm
Conventional Pump Therapy
Insulin will be delivered by subcutaneous insulin infusion pump with participants usual infusion rate
Eligibility Criteria
Check the participation requirements, including inclusion and exclusion rules, age limits, and whether healthy volunteers are accepted.
Inclusion Criteria
2. The participant will have been on insulin pump therapy for at least 3 months.
3. HbA1c 7.5% to 12%.
4. Self-reported or documented history of missed-bolus for meals during the previous 6 months.
Exclusion Criteria
2. Severe hypoglycemic episode within one month of screening.
3. Pregnancy.
4. Current use of oral glucocorticoid medication (except low stable dose). Stable doses of inhaled steroids are acceptable.
5. Known or suspected allergy to the trial products, including the meal content.
6. Other serious medical illness likely to interfere with study participation or with the ability to complete the trial by the judgment of the investigator.
7. Failure to comply with team's recommendations (e.g. not willing to eat meals/snacks, not willing to change pump parameters, etc.).
12 Years
18 Years
ALL
No
Sponsors
Meet the organizations funding or collaborating on the study and learn about their roles.
McGill University
OTHER
Responsible Party
Identify the individual or organization who holds primary responsibility for the study information submitted to regulators.
Ahmad Haidar
Assistant Professor
Locations
Explore where the study is taking place and check the recruitment status at each participating site.
McGill University Health Centre
Montreal, Quebec, Canada
Countries
Review the countries where the study has at least one active or historical site.
Other Identifiers
Review additional registry numbers or institutional identifiers associated with this trial.
Missed Bolus 9h
Identifier Type: -
Identifier Source: org_study_id
More Related Trials