Dual-hormone Closed-loop Glucose Control in Type 1 Diabetes

NCT ID: NCT04053712

Last Updated: 2022-08-18

Study Results

Results pending

The study team has not published outcome measurements, participant flow, or safety data for this trial yet. Check back later for updates.

Basic Information

Get a concise snapshot of the trial, including recruitment status, study phase, enrollment targets, and key timeline milestones.

Recruitment Status

COMPLETED

Clinical Phase

PHASE4

Total Enrollment

13 participants

Study Classification

INTERVENTIONAL

Study Start Date

2019-07-16

Study Completion Date

2021-03-19

Brief Summary

Review the sponsor-provided synopsis that highlights what the study is about and why it is being conducted.

Despite recent pharmacological and technological advantages, hypoglycemia remains to be the key limiting factor in achieving optimal glycemic control in people with type 1 diabetes. State-of-the-art treatment for type 1 diabetes is insulin in pens or pumps that focus on reducing hyperglycemia after relative insulin deficiency e.g. after food intake. In recent years, we focused on adding low-dose glucagon to insulin therapies for the treatment and prevention of hypoglycemia - referred to as "dual-hormone treatment". We have shown that low-dose glucagon is efficient in treating mild hypoglycemia and that several factors may affect its glucose response. Our next step is to test whether the combined delivery of insulin and glucagon can improve glucose control in individuals with type 1 diabetes. In this proposal, we want to test the efficacy, safety and feasibility of a dual-hormone closed-loop system, also known as an artificial pancreas. The closed-loop system involves automatic infusion of glucagon and insulin based on continuous glucose measurements. The system will be tested in a 33-hour in-clinic study comparing the glucose control by the combined automatic delivery of insulin and glucagon with the automatic delivery of insulin-only. The study is performed at Steno Diabetes Center Copenhagen (SDCC) in collaboration with the Technical University of Denmark (DTU). We expect that the study will clarify whether low-dose glucagon added to insulin therapy can improve the glucose control in adults with type 1 diabetes. We believe that the utilization of glucagon will allow for a weight neutral optimization of glucose control, reduce risk of hypoglycemia and reduce disease burden that will reduce diabetes complications and cardiovascular diseases.

Detailed Description

Dive into the extended narrative that explains the scientific background, objectives, and procedures in greater depth.

Rationale: We hypothesize that our newly developed dual-hormone insulin-glucagon closed-loop system (DCL) is safe, efficient and superior to our single-hormone insulin-only closed-loop system (SCL). The study aims to compare the glucose control achieved by DCL with our SCL.

Design: A randomized single-blinded placebo-controlled cross-over 33-hour in-clinic study of glucose control achieved with DCL versus SCL in adults and adolescents with type 1 diabetes.

Participants: 13 insulin-pump treated T1D participants will be included, if they are 15-80 years old, have T1D for ≥ 3 years, use insulin pumps with FiAsp®, and have an HbA1c≤ 8.5% (69 mmol/mol).

Procedures: In this two-phase study 1) we test the operability of our closed-loop systems and 2) compare glucose control by DCL with SCL. The two studies are identical except for the blinding procedures. In the first phase (pilot study), four participants are included, and the glucagon/saline pump is not masked. In the second phase (main study), 13 participants are included, and are as well as the investigators blinded for the content in the glucagon/saline pump.

Two days prior to study visit, a CGM (Dexcom® G6) is place on the participant's abdomen. At study visits, participants arrive in the evening at our research unit and get their insulin pump disconnected. Two study pumps (Dana Diabecare RS®, SOOIL) are attached: one pump infuses insulin (FiAsp®, Novo Nordisk) and the other infuses either glucagon (GlucaGen®, Novo Nordisk) or saline. Once a sampling cannula is placed in an antecubital vein, the study is initiated and the closed-loop system (DCL vs SCL) takes over the glucose control for the next 33 hours. Except from the control algorithm (SCL vs DCL), the study days are identical. Participants can move around freely in the clinic for 33 hours but will perform a 45-min moderate (50% VO2max) exercise session, consume three meals with variant carbohydrate content, and sleep during two overnight periods. Participants will be monitored frequently with blood samples (drawn from the antecubital vein), blood pressure, pulse, and VAS scale for nausea.

Conditions

See the medical conditions and disease areas that this research is targeting or investigating.

Type 1 Diabetes Hypoglycemia

Study Design

Understand how the trial is structured, including allocation methods, masking strategies, primary purpose, and other design elements.

Allocation Method

RANDOMIZED

Intervention Model

CROSSOVER

A randomized single-blinded placebo-controlled cross-over 33-hour in-clinic study in adults with type 1 diabetes.
Primary Study Purpose

TREATMENT

Blinding Strategy

SINGLE

Participants

Study Groups

Review each arm or cohort in the study, along with the interventions and objectives associated with them.

Single-hormone

FiAsp (R) - Saline

Group Type PLACEBO_COMPARATOR

Closed-loop system

Intervention Type DEVICE

Closed-loop system comprise of two DANA RS (R) insulin pumps (FiAsp-GlucaGen vs FiAsp-saline), one DexCom G6 sensor, and a smartphone for the control algorithm.

Dual-hormone

FiAsp(R) - GlucaGen(R)

Group Type ACTIVE_COMPARATOR

Glucagon

Intervention Type DRUG

GlucaGen(R), Novo Nordisk, DK

Closed-loop system

Intervention Type DEVICE

Closed-loop system comprise of two DANA RS (R) insulin pumps (FiAsp-GlucaGen vs FiAsp-saline), one DexCom G6 sensor, and a smartphone for the control algorithm.

Interventions

Learn about the drugs, procedures, or behavioral strategies being tested and how they are applied within this trial.

Glucagon

GlucaGen(R), Novo Nordisk, DK

Intervention Type DRUG

Closed-loop system

Closed-loop system comprise of two DANA RS (R) insulin pumps (FiAsp-GlucaGen vs FiAsp-saline), one DexCom G6 sensor, and a smartphone for the control algorithm.

Intervention Type DEVICE

Eligibility Criteria

Check the participation requirements, including inclusion and exclusion rules, age limits, and whether healthy volunteers are accepted.

Inclusion Criteria

* Age ≥ 18 years
* T1D ≥ 2 years
* Insulin pump therapy ≥ 1
* Currently treated with FiAsp® - insulin

Exclusion Criteria

* Pregnancy or nursing
* Inability and willingness to comply with all protocol procedures, e.g. exercise, sleeping, blood sampling, and meal consumption
* Plan to become pregnant or sexually active and not using adequate contraceptive methods (sterilization, intrauterine device, contraceptive pill, patch or injection)
* Hypoglycemia unawareness (self-reported lack of hypoglycemia symptoms when blood glucose is \< 3.0 mmol/l)
* Use of anti-diabetic medicine (other than insulin), corticosteroids or other drugs affecting glucose metabolism during or within 30 days prior to study participation
* History of coronary artery disease or congestive heart failure
* Abnormal ECG suggestive of coronary artery disease and increased risk of malignant arrhythmia
* Allergy to glucagon or lactose
* Pheochromocytoma
* Other concomitant medical or psychological condition that according to the investigator's assessment makes the patient unsuitable for study participation

Withdrawal criteria

* In case of pregnancy (or desire for pregnancy), female subjects are withdrawn
* Lack of compliance to any of the important study procedures in the discretion of the investigator
* Unacceptable adverse effects in the discretion of the investigator
* Withdrawal on participants request will be accepted at any time without further justification

Patients who complete or withdraw from the study continue their usual quarterly follow-up visits at the diabetes clinic. Withdrawal does not affect their statutory patient rights.
Minimum Eligible Age

18 Years

Eligible Sex

ALL

Accepts Healthy Volunteers

No

Sponsors

Meet the organizations funding or collaborating on the study and learn about their roles.

Technical University of Denmark

OTHER

Sponsor Role collaborator

University of Copenhagen

OTHER

Sponsor Role collaborator

Danish Diabetes Academy

OTHER

Sponsor Role collaborator

Steno Diabetes Center Copenhagen

OTHER

Sponsor Role lead

Responsible Party

Identify the individual or organization who holds primary responsibility for the study information submitted to regulators.

Responsibility Role SPONSOR

Principal Investigators

Learn about the lead researchers overseeing the trial and their institutional affiliations.

Ajenthen G Ranjan, MD, PhD

Role: PRINCIPAL_INVESTIGATOR

Steno Diabetes Center Copenhagen

Locations

Explore where the study is taking place and check the recruitment status at each participating site.

Steno Diabetes Center Copenhagen

Gentofte Municipality, , Denmark

Site Status

Countries

Review the countries where the study has at least one active or historical site.

Denmark

Other Identifiers

Review additional registry numbers or institutional identifiers associated with this trial.

2019-001631-31

Identifier Type: EUDRACT_NUMBER

Identifier Source: secondary_id

2019043528

Identifier Type: REGISTRY

Identifier Source: secondary_id

2019043269

Identifier Type: REGISTRY

Identifier Source: secondary_id

CIV-19-04-028465

Identifier Type: REGISTRY

Identifier Source: secondary_id

H-19026331

Identifier Type: -

Identifier Source: org_study_id

More Related Trials

Additional clinical trials that may be relevant based on similarity analysis.

GIP and GLP-1 in Type 1 Diabetes
NCT01739283 COMPLETED NA