Artificial Pancreas Control System in an Inpatient Setting
NCT ID: NCT01552603
Last Updated: 2016-06-03
Study Results
Outcome measurements, participant flow, baseline characteristics, and adverse events have been published for this study.
View full resultsBasic Information
Get a concise snapshot of the trial, including recruitment status, study phase, enrollment targets, and key timeline milestones.
COMPLETED
PHASE2
14 participants
INTERVENTIONAL
2012-03-31
2013-09-30
Brief Summary
Review the sponsor-provided synopsis that highlights what the study is about and why it is being conducted.
Related Clinical Trials
Explore similar clinical trials based on study characteristics and research focus.
Artificial Pancreas Control System in an Outpatient Setting
NCT01871870
Integration of Continuous Glucose Monitoring Into a BiHormonal Closed-Loop Artificial Pancreas
NCT01161862
Single Hormone Closed Loop Study With PDT Sensor
NCT03528174
Feasibility Study Using Zone-MPC Controller (Zone-Model Predictive Control) and Health Monitoring System (HMS)
NCT01472406
A Multicenter Study of Outpatient Automated Blood Glucose Control With a Bihormonal Bionic Pancreas
NCT02092220
Detailed Description
Dive into the extended narrative that explains the scientific background, objectives, and procedures in greater depth.
Conditions
See the medical conditions and disease areas that this research is targeting or investigating.
Study Design
Understand how the trial is structured, including allocation methods, masking strategies, primary purpose, and other design elements.
NA
SINGLE_GROUP
TREATMENT
NONE
Study Groups
Review each arm or cohort in the study, along with the interventions and objectives associated with them.
Artificial Pancreas Control
Type 1 Diabetes Mellitus subjects who fit the inclusion/exclusion criteria will undergo artificial pancreas closed-loop study for 28 hours. For the entire study, the adaptive component of Artificial Pancreas Control Software will be used to control the subject's blood glucose.
Artificial Pancreas Control Software
This master controller software is used in conjunction with two subcutaneous continuous glucose monitoring systems and two Omnipod pumps, one for administering aspart insulin (NovoLog) and one for administering glucagon (GlucaGen), to control blood glucose levels. The insulin and glucagon infusion rates are determined by an automated version of the Adaptive Proportional Derivative (APD) insulin and glucagon control algorithm.
Interventions
Learn about the drugs, procedures, or behavioral strategies being tested and how they are applied within this trial.
Artificial Pancreas Control Software
This master controller software is used in conjunction with two subcutaneous continuous glucose monitoring systems and two Omnipod pumps, one for administering aspart insulin (NovoLog) and one for administering glucagon (GlucaGen), to control blood glucose levels. The insulin and glucagon infusion rates are determined by an automated version of the Adaptive Proportional Derivative (APD) insulin and glucagon control algorithm.
Eligibility Criteria
Check the participation requirements, including inclusion and exclusion rules, age limits, and whether healthy volunteers are accepted.
Inclusion Criteria
* Male or female subjects 21 to 65 years of age.
* Current use of an insulin pump.
* Willingness to follow all study procedures, including attending all clinic visits.
* Willingness to sign informed consent and HIPAA documents.
Exclusion Criteria
* Renal insufficiency (serum creatinine of 2.0 mg/dL or greater).
* Serum ALT or AST equal to or greater than 3 times the upper limit of normal; hepatic synthetic insufficiency as defined as a serum albumin of less than 3.3 g/dL; or serum bilirubin of over 2.
* Adrenal insufficiency
* Hematocrit of less than or equal to 34%.
* A history of cerebrovascular disease or coronary artery disease regardless of the time since occurrence.
* Congestive heart failure, NYHA class III or IV.
* Diagnosis of 2nd or 3rd degree heart block or any arrhythmia judged by the investigator to be exclusionary.
* Any active infection.
* Visual impairment preventing reading of glucose meter values or continuous glucose monitoring device.
* Physical impairment impeding the ability to use a glucose meter or glucose monitoring device.
* Active foot ulceration.
* Severe peripheral arterial disease characterized by ischemic rest pain or severe claudication.
* Active alcohol abuse, substance abuse, or severe mental illness (as judged by the principal investigator).
* Active malignancy, except basal cell or squamous cell skin cancers.
* Major surgical operation within 30 days prior to screening.
* Seizure disorder.
* Chronic usage of any immunosuppressive medication (such as cyclosporine, azathioprine, sirolimus, or tacrolimus).
* Current administration of oral or parenteral corticosteroids.
* Use of an investigational drug within 30 days prior to screening.
* Bleeding disorder, treatment with warfarin, or platelet count below 50,000.
* Allergy to aspart insulin.
* Allergy to glucagon.
* Past history of pheochromocytoma or a family history of MEN 2, neurofibromatosis, or von Hippel-Lindau disease.
* Insulin resistance requiring more than 200 units per day.
* Need for uninterrupted treatment of acetaminophen.
* Intolerance of mild hypoglycemia (glucose 60-70 mg/dl).
* History of hypoglycemic unawareness.
* Insulin antibody level of ≥ 100 µUnits/ml.
* C peptide level of ≥0.5 ng/ml.
* Any concurrent illness, other than diabetes, that is not controlled by a stable therapeutic regimen.
* Any reason the principal investigator deems exclusionary
21 Years
65 Years
ALL
No
Sponsors
Meet the organizations funding or collaborating on the study and learn about their roles.
Juvenile Diabetes Research Foundation
OTHER
Legacy Health System
OTHER
Responsible Party
Identify the individual or organization who holds primary responsibility for the study information submitted to regulators.
W. Kenneth Ward
Senior Scientist
Principal Investigators
Learn about the lead researchers overseeing the trial and their institutional affiliations.
W K Ward, MD
Role: PRINCIPAL_INVESTIGATOR
Legacy Health Research
Locations
Explore where the study is taking place and check the recruitment status at each participating site.
Legacy Good Samaritan Hospital
Portland, Oregon, United States
Oregon Health and Science University
Portland, Oregon, United States
Countries
Review the countries where the study has at least one active or historical site.
References
Explore related publications, articles, or registry entries linked to this study.
El Youssef J, Castle JR, Branigan DL, Massoud RG, Breen ME, Jacobs PG, Bequette BW, Ward WK. A controlled study of the effectiveness of an adaptive closed-loop algorithm to minimize corticosteroid-induced stress hyperglycemia in type 1 diabetes. J Diabetes Sci Technol. 2011 Nov 1;5(6):1312-26. doi: 10.1177/193229681100500602.
Other Identifiers
Review additional registry numbers or institutional identifiers associated with this trial.
2011.11
Identifier Type: -
Identifier Source: org_study_id
More Related Trials
Additional clinical trials that may be relevant based on similarity analysis.