Comparative STudy of the ARGos Biometer Compared to UltraSound Biometer in B-mode in Case of Measure Failure With a the Conventional Biometer
NCT ID: NCT05534373
Last Updated: 2023-01-09
Study Results
The study team has not published outcome measurements, participant flow, or safety data for this trial yet. Check back later for updates.
Basic Information
Get a concise snapshot of the trial, including recruitment status, study phase, enrollment targets, and key timeline milestones.
UNKNOWN
110 participants
OBSERVATIONAL
2023-02-28
2023-05-31
Brief Summary
Review the sponsor-provided synopsis that highlights what the study is about and why it is being conducted.
Non-contact optical biometry has become the gold-standard because of its ease of use, accuracy, and reproducibility. However, the main disadvantage of the optical methods is their inability to obtain axial length measurements in approximately 10% of eyes, typically those with dense posterior subcapsular cataracts.
By Using SS-OCT device, it has been reported that the AL measurements cannot be made in 0.6 to 7.4% of cases . Therefore, measurement by US biometer is still necessary for advanced cataract. The ultrasound measure the LA between the corneal epithelium and the vitreomacular interface. Ultrasound in B mode (or Brilliance) with the help of the control vector allows a 2-dimensional control of the plan used for measurement. This method is used in current practice in our centers when LA measurements is not possible with our optical SS-biometer.
Recently Alcon has integrated the ARGOS® biometer's diagnostic testing with Alcon's Cataract Refractive Suite technologies. ARGOS® is a non-invasive, non-contact biometer based on swept-source optical coherence tomography (SS-OCT). The device is intended to acquire ocular measurements as well as perform calculations to determine the appropriate intraocular lens (IOL) power and type for implantation during intraocular lens placement. ARGOS® measures the following 9 parameters: Axial Length, Corneal Thickness, Anterior Chamber Depth, Lens Thickness, K-values (Radii of flattest and steepest meridians), Astigmatism, White-to-White (corneal diameter) and Pupil Size. The Reference Image functionality is intended for use as a preoperative and postoperative image capture tool. ARGOS® includes an operation mode for when the retina is hardly or not visible at all denominated the "Enhanced Retinal Visualization mode" (ERV) that allows, in most cases, visualization of the retina. This signal in the retinal region is enhanced by shifting the coherence function (Argos Users manual).
In a prospective observational study conducted in 2 centers in USA involving 107 eyes, they have evaluated the repeatability and reproducibility of ARGOS® measurements in comparison with IOLMaster®500 and LENSTAR LS 900. They have shown that the AL acquisition rate was higher with ARGOS® (96%) compared with both LENSTAR LS 900 (79%) and IOLMaster®500 (77%). The reason was that ARGOS® was more successful at measuring AL in eyes with dense cataract.
Related Clinical Trials
Explore similar clinical trials based on study characteristics and research focus.
A Randomized Study of Intraocular Caliper-assisted Capsulotomy for Age-related Cataract Patients With Corneal Limbus Opacity
NCT04977102
Assessment Of Anterior Chamber Configuration Changes After Phacoemulsification
NCT02238002
"Comparative Study of High-frequency Pulsed Vacuum Technology Versus Phacoemulsification for Cataract Surgery
NCT07074431
IOP and Ocular Biometrics Changes After Phacoemulsification in Glaucoma Patients and Controls
NCT04334473
Improved Operation of Low Intraocular Pressure in Phacoemulsification for Patients With High Myopia Complicated With Cataract
NCT05201677
Detailed Description
Dive into the extended narrative that explains the scientific background, objectives, and procedures in greater depth.
These observations lead us to propose a retrospective study to compare Argos to our gold standard "ultrasound biometer in mode B" for LA measurements in case of failure with the conventional optical biometer used in our current practice (Lenstar LS900, IOLMaster 500, 700) In current practice, the biometry measurements are conducted with our conventional optical biometer during the visit prior to cataract surgery.
At the same time, measures will be conducted on Argos with or without the ERV mode If axial length measurements are impossible with our conventional optical biometer due to the level of cataract density, axial length measurements will be conducted with our ultrasound biometer in mode-B (Quantel Medical, Aviso S with the 10MHz probe) according to our current practice.
We will retrospectively collect the consecutive data from eyes for which axial length measurements with our conventional biometer were not possible
Conditions
See the medical conditions and disease areas that this research is targeting or investigating.
Study Design
Understand how the trial is structured, including allocation methods, masking strategies, primary purpose, and other design elements.
CASE_ONLY
RETROSPECTIVE
Eligibility Criteria
Check the participation requirements, including inclusion and exclusion rules, age limits, and whether healthy volunteers are accepted.
Inclusion Criteria
* All consecutive patient measured on Argos and any other conventional optical biometer and presenting a failure with one of the conventional optical biometer in AL measurement due to cataract density
Exclusion Criteria
* Patients who are informed and objected to participating to the research
* Patient subject to legal protection measures.
18 Years
ALL
No
Sponsors
Meet the organizations funding or collaborating on the study and learn about their roles.
Assistance Publique - Hôpitaux de Paris
OTHER
Responsible Party
Identify the individual or organization who holds primary responsibility for the study information submitted to regulators.
Locations
Explore where the study is taking place and check the recruitment status at each participating site.
Hôpital Avicenne
Bobigny, , France
Countries
Review the countries where the study has at least one active or historical site.
Central Contacts
Reach out to these primary contacts for questions about participation or study logistics.
Other Identifiers
Review additional registry numbers or institutional identifiers associated with this trial.
APHP220627
Identifier Type: -
Identifier Source: org_study_id
More Related Trials
Additional clinical trials that may be relevant based on similarity analysis.