Clinical and Radiographic Outcomes of Spine Surgeries Utilizing Capri Cervical and Thoracolumbar Corpectomy Cage Systems

NCT ID: NCT05456633

Last Updated: 2023-09-25

Study Results

Results pending

The study team has not published outcome measurements, participant flow, or safety data for this trial yet. Check back later for updates.

Basic Information

Get a concise snapshot of the trial, including recruitment status, study phase, enrollment targets, and key timeline milestones.

Recruitment Status

WITHDRAWN

Study Classification

OBSERVATIONAL

Study Start Date

2023-10-31

Study Completion Date

2026-08-31

Brief Summary

Review the sponsor-provided synopsis that highlights what the study is about and why it is being conducted.

This is a retrospective and prospective observational, multi center study of subjects who have undergone or will undergo vertebral body replacement surgery in the cervical or thoracolumbar spine utilizing Stryker Capri Corpectomy Cages.

The primary study hypothesis to determine effectiveness, is that the mean improvement in NDI (cervical) or ODI (thoracolumbar) score from baseline meets or exceeds 15-points at 24 months for Stryker Capri Corpectomy Cage systems individually.

Detailed Description

Dive into the extended narrative that explains the scientific background, objectives, and procedures in greater depth.

Corpectomy procedures are utilized to treat a variety of spinal pathologies including tumor, often as a result of metastatic spine disease, fracture frequently attributed to trauma, osteomyelitis (infection), and degenerative disorders which require reconstruction to achieve decompression of the spinal cord or neural tissues. Patients may present with pain, spinal instability, and neurological deficits. Corpectomy involves a resection or excision of the affected vertebrae and intervertebral disc(s), followed by placement of a vertebral body replacement (VBR) to reconstruct the anterior column of the spine and restore stability and alignment.

Common indications for VBR procedures include spinal instability due to vertebral fractures, vertebral compression fractures, and fractures related to malignancy or infection and control of disease, such as metastatic disease in the spine. Causes of spinal fractures may include falls, sports, and motor vehicle accidents. Spinal tumors are often caused by metastases of the skeletal system, which commonly affect the spine. Additionally, VBR procedures may be considered in response to cervical spondylotic myelopathy which is a progressive degenerative disease and a common cause of cervical spinal cord dysfunction and cervical myelopathy in people over the age of 55. Corpectomy (or vertebrectomy) with reconstruction has become a common surgical procedure used for decompression and reconstruction of the spine. Traditionally, reconstruction has included autograft, allograft, and bone substitutes; however, the use of grafts alone have been reported to lead to complications such as donor site morbidity, high rates of pseudarthrosis, and delayed union. The evolution of corpectomy cages has led to improvements in both clinical and radiographic outcomes. Titanium mesh cages were one of the earliest types of non-graft-based corpectomy cages, providing a biocompatible method of rapidly stabilizing the affected segments, reducing donor site morbidity, and improving outcomes.

This study will examine use of the Capri Corpectomy Cage systems in cervical and/or thoracolumbar cases in the treatment of trauma, tumor, infection (cervical only), or degeneration (cervical only) using static (cervical only) or expandable (cervical and thoracolumbar) cages. Clinical efficacy and safety will be assessed in this post-market study through evaluation of patient outcomes in comparison to baseline, pre-operative conditions.

Capri Corpectomy system implants are VBR devices that are designed in a variety of lengths, widths, and heights to match the patient's anatomy. The caudal and cephalad ends of the implant have teeth which are designed to engage with the vertebral body endplates. The side walls of the implants contain windows that may be used for graft incorporation. Instruments are used for inserting the associated implant components using standard surgical techniques. There are curettes, scrapers, and box chisels for preparing the disc spaces and vertebral body endplates. Insertion instruments are available for inserting the implant. Capri Corpectomy Cage systems are available as cervical static cages (comprised of titanium alloy) and cervical or thoracolumbar adjustable (i.e., expandable) cages (comprised of titanium alloy and cobalt chrome). Devices may be implanted via posterior, anterior, or lateral approaches.

Conditions

See the medical conditions and disease areas that this research is targeting or investigating.

Thoracolumbar Spine Cervical Spine Injury

Study Design

Understand how the trial is structured, including allocation methods, masking strategies, primary purpose, and other design elements.

Observational Model Type

COHORT

Study Time Perspective

OTHER

Study Groups

Review each arm or cohort in the study, along with the interventions and objectives associated with them.

Capri Cervical 3D Static

Subjects who have undergone or will undergo VBR in the cervical spine (C2 to T1 in the USA, C3 to C7 outside of the USA) to replace diseased or damaged vertebral bodies due to tumor, trauma (i.e., fracture), or osteomyelitis, or for reconstruction following corpectomy performed to achieve decompression of the spine cord and neural tissues in cervical degenerative disorders

Capri Cervical Static

Intervention Type DEVICE

When used in the cervical spine (C2-T1), CAPRI Static cages are intended for use in skeletally mature patients to replace a diseased or damaged vertebral body caused by tumor, fracture, or osteomyelitis, or for reconstruction following corpectomy performed to achieve decompression of the spinal cord and neural tissues in cervical degenerative disorders.

Capri Cervical 3D Expendable

Subjects who have undergone or will undergo VBR in the cervical spine (C2 to T1 in the USA, C3 to C7 outside of the USA) to replace diseased or damaged vertebral bodies due to tumor, trauma (i.e., fracture), or osteomyelitis, or for reconstruction following corpectomy performed to achieve decompression of the spine cord and neural tissues in cervical degenerative disorders

CAPRI Static Expandable

Intervention Type OTHER

When used in the cervical spine (C2-T1), CAPRI Static Expandable cages are intended for use in skeletally mature patients to replace a diseased or damaged vertebral body caused by tumor, fracture, or osteomyelitis, or for reconstruction following corpectomy performed to achieve decompression of the spinal cord and neural tissues in cervical degenerative disorders.

Capri Thoracolumbar Expandable

Subjects who have undergone or will undergo VBR in the thoracolumbar spine (T1 to L5) with Capri Thoracolumbar Expandable to replace collapsed, damaged, or unstable vertebral bodies due to tumor or trauma (i.e., fracture)

Capri Thoracolumbar

Intervention Type DEVICE

Intended for use to replace a collapsed, damaged, or unstable vertebral body due to tumor and trauma (i.e. fracture).

Interventions

Learn about the drugs, procedures, or behavioral strategies being tested and how they are applied within this trial.

Capri Cervical Static

When used in the cervical spine (C2-T1), CAPRI Static cages are intended for use in skeletally mature patients to replace a diseased or damaged vertebral body caused by tumor, fracture, or osteomyelitis, or for reconstruction following corpectomy performed to achieve decompression of the spinal cord and neural tissues in cervical degenerative disorders.

Intervention Type DEVICE

CAPRI Static Expandable

When used in the cervical spine (C2-T1), CAPRI Static Expandable cages are intended for use in skeletally mature patients to replace a diseased or damaged vertebral body caused by tumor, fracture, or osteomyelitis, or for reconstruction following corpectomy performed to achieve decompression of the spinal cord and neural tissues in cervical degenerative disorders.

Intervention Type OTHER

Capri Thoracolumbar

Intended for use to replace a collapsed, damaged, or unstable vertebral body due to tumor and trauma (i.e. fracture).

Intervention Type DEVICE

Eligibility Criteria

Check the participation requirements, including inclusion and exclusion rules, age limits, and whether healthy volunteers are accepted.

Inclusion Criteria

* Skeletally mature
* Willingness and ability to comply with the requirements of the protocol including follow-up requirements
* Willing and able to sign a study specific informed consent form. For fully retrospective enrollments, i.e., subjects that already have 24-month follow-up data available, the Principal Investigator will request a waiver of the written informed consent requirement.
* Has undergone or will undergo VBR in the cervical spine (C2 to T1 in the USA, C3 to C7 outside of the USA) using either Capri Cervical 3D Static OR Capri Cervical 3D Expandable to replace diseased or damaged vertebral bodies due to tumor, trauma (i.e., fracture), or osteomyelitis, or for reconstruction following corpectomy performed to achieve decompression of the spine cord and neural tissues in cervical degenerative disorders -OR- Has undergone or will undergo VBR in the thoracolumbar spine (T1 to L5) using Capri Thoracolumbar Expandable to replace collapsed, damaged, or unstable vertebral bodies due to tumor or trauma (i.e., fracture)
* Score at least 30 points on the ODI or at least 30 points on the NDI at screening (or before surgery for retrospective enrollment) (on a 100-point scale)

Exclusion Criteria

* Presence of infection, except within the spinal indications for use of this product
* Pregnancy (pregnant at the time of enrollment or intends to become pregnant during the course of the study)
* Metabolic disorders of calcified tissues
* Grossly distorted anatomy
* Inadequate tissue coverage
* Drug / alcohol abuse
* Mental illness such as a psychiatric or cognitive impairment, that in the opinion of the investigator, would interfere with the subject's ability to comply with the study requirements or patient reported outcomes (e.g., Alzheimer's Disease)
* General neurological conditions
* Immunosuppressive disorders
* Subjects with known sensitivities to materials in the device
* Obesity defined as a BMI greater than 30
* Subjects who are unwilling to restrict activities or follow medical advice
* Any condition where the implants interfere with anatomical structures or precludes the benefit of spinal surgery
* Biological factors such as smoking, use of nonsteroidal anti-inflammatory agents, use of anticoagulants, etc.

* Subjects that adhere to the specified washout period detailed below can be enrolled: Smoking cessation must occur at a minimum of 4 weeks prior to surgery; Nonsteroidal anti-inflammatories (NSAIDs) should be stopped at a minimum of 7 days prior to surgery; Anticoagulants should be stopped at the discretion of the operating surgeon as the washout period varies for each medication
* Trauma subjects that are unable to adhere to the washout period can be enrolled; however, the aforementioned biological factors will need to be documented during data collection
* Prior fusion at the level(s) to be treated
* Incarcerated at the time of study enrollment
* Current participation in an investigational study that may impact study outcomes
* Involved in current or pending spinal litigation or a workman compensation claim
Eligible Sex

ALL

Accepts Healthy Volunteers

No

Sponsors

Meet the organizations funding or collaborating on the study and learn about their roles.

Stryker Spine

INDUSTRY

Sponsor Role collaborator

K2M, Inc.

INDUSTRY

Sponsor Role lead

Responsible Party

Identify the individual or organization who holds primary responsibility for the study information submitted to regulators.

Responsibility Role SPONSOR

Other Identifiers

Review additional registry numbers or institutional identifiers associated with this trial.

CAS-031

Identifier Type: -

Identifier Source: org_study_id

More Related Trials

Additional clinical trials that may be relevant based on similarity analysis.

Clinical Outcome Measure at Stryker Spine
NCT06226272 NOT_YET_RECRUITING
Posterior Cervical Fixation Study
NCT04770571 ENROLLING_BY_INVITATION