View full resultsBasic Information
Get a concise snapshot of the trial, including recruitment status, study phase, enrollment targets, and key timeline milestones.
TERMINATED
NA
35 participants
INTERVENTIONAL
2022-06-30
2023-04-07
Brief Summary
Review the sponsor-provided synopsis that highlights what the study is about and why it is being conducted.
Related Clinical Trials
Explore similar clinical trials based on study characteristics and research focus.
Clinical Investigation of the TECNIS® Next-Generation Intraocular Lens, Model DEN00V
NCT05574959
Post-market Study to Obtain Surgeon Feedback on Clinical Outcome in Eyes Implanted With TECNIS Toric II IOL
NCT04210232
Clinical Investigation of the Safety and Effectiveness of an Investigational Model of the TECNIS® Intraocular Lens
NCT03949335
Clinical Investigation of the TECNIS 1-Piece Intraocular Lens
NCT05090787
Clinical Investigation of Two Tecnis Investigational Lenses
NCT04890249
Detailed Description
Dive into the extended narrative that explains the scientific background, objectives, and procedures in greater depth.
Conditions
See the medical conditions and disease areas that this research is targeting or investigating.
Study Design
Understand how the trial is structured, including allocation methods, masking strategies, primary purpose, and other design elements.
RANDOMIZED
PARALLEL
TREATMENT
DOUBLE
Study Groups
Review each arm or cohort in the study, along with the interventions and objectives associated with them.
Eyhance Toric II IOL
Model DIU
Model DIU
Subjects will be randomized to a treatment group (masked) in ratio 1:1:1. Surgeons will perform standardized, small-incision, cataract surgery and implant the study lenses using a JJSV-validated insertion system qualified for use with the lens to be implanted.
TECNIS Synergy Toric II
Model DFW
Model DFW
Subjects will be randomized to a treatment group (masked) in ratio 1:1:1. Surgeons will perform standardized, small-incision, cataract surgery and implant the study lenses using a JJSV-validated insertion system qualified for use with the lens to be implanted.
TECNIS Toric 1-Piece IOL
Model ZCT
Model ZCT
Subjects will be randomized to a treatment group (masked) in ratio 1:1:1. Surgeons will perform standardized, small-incision, cataract surgery and implant the study lenses using a JJSV-validated insertion system qualified for use with the lens to be implanted.
Interventions
Learn about the drugs, procedures, or behavioral strategies being tested and how they are applied within this trial.
Model DIU
Subjects will be randomized to a treatment group (masked) in ratio 1:1:1. Surgeons will perform standardized, small-incision, cataract surgery and implant the study lenses using a JJSV-validated insertion system qualified for use with the lens to be implanted.
Model DFW
Subjects will be randomized to a treatment group (masked) in ratio 1:1:1. Surgeons will perform standardized, small-incision, cataract surgery and implant the study lenses using a JJSV-validated insertion system qualified for use with the lens to be implanted.
Model ZCT
Subjects will be randomized to a treatment group (masked) in ratio 1:1:1. Surgeons will perform standardized, small-incision, cataract surgery and implant the study lenses using a JJSV-validated insertion system qualified for use with the lens to be implanted.
Eligibility Criteria
Check the participation requirements, including inclusion and exclusion rules, age limits, and whether healthy volunteers are accepted.
Inclusion Criteria
1. Male or female at least 22 years of age
2. Have a cataract in one or both eyes, with planned phacoemulsification and intraocular lens implantation with a toric intraocular lens
3. Regular corneal astigmatism and predicted postoperative residual astigmatism of less than 1.00 D after implantation with a toric intraocular lens in the study eye(s)
4. Availability, willingness and sufficient cognitive awareness to understand the purpose of the examination procedures and comply with postoperative visits
5. Signed informed consent and HIPAA authorization or equivalent documentation necessary to comply with applicable privacy laws pertaining to medical treatment in the governing countries.
Exclusion Criteria
1. Best-corrected distance visual acuity better than 20/40 Snellen (0.3 logMAR)
2. Potential visual acuity estimated to be worse than 20/32 Snellen (0.2 logMAR)
3. Prior corneal refractive (LASIK, LASEK, RK, PRK, etc.) or intraocular surgery, Including prophylactic peripheral iridotomies and peripheral laser retinal repairs
4. Corneal abnormalities such as stromal, epithelial or endothelial dystrophies (e.g., any observed guttata) that are predicted to cause visual acuity losses to a level worse than 20/30 Snellen during the study
5. Pupil abnormalities (non-reactive, fixed pupils, or abnormally shaped pupils) or unable to dilate to visualize IOL axis (approximately 6.0 mm)
6. Inability to achieve keratometric stability for contact lens wearers (as defined in Section 10.3 Preoperative Procedures)
7. Recent ocular trauma or ocular surgery that is not resolved/stable or may affect visual outcomes or increase risk to the subject
8. Use of systemic or ocular medications that may affect vision
9. Prior, current, or anticipated use during the course of the 6-month study of tamsulosin or silodosin (e.g., Flomax, Flomaxtra, Rapaflo) that may, in the opinion of the investigator, confound the outcome or increase the risk to the subject (e.g., poor dilation or a lack of adequate iris structure to perform standard cataract surgery)
10. Poorly controlled diabetes
11. Acute, chronic, or uncontrolled systemic or ocular disease or illness that, in the opinion of the investigator, would increase the operative risk or confound the outcome(s) of the study (e.g., immunocompromised, connective tissue disease, suspected glaucoma, glaucomatous changes in the fundus or visual field, ocular inflammation, etc.). Note: controlled ocular hypertension without glaucomatous changes (optic nerve cupping and visual field loss) is acceptable.
12. Pregnancy, planned pregnancy, presently lactating, or another condition associated with hormonal fluctuation that could lead to refractive changes
13. Concurrent participation or participation in any other clinical study within 30 days prior to the preoperative visit
14. Any other systemic or ocular disease that, in the opinion of the investigator, may affect the patient's eligibility for the study, affect visual acuity or may require surgical intervention during the study (e.g., macular degeneration, cystoid macular edema, diabetic retinopathy, etc.).
22 Years
ALL
No
Sponsors
Meet the organizations funding or collaborating on the study and learn about their roles.
Johnson & Johnson Surgical Vision, Inc.
INDUSTRY
Responsible Party
Identify the individual or organization who holds primary responsibility for the study information submitted to regulators.
Principal Investigators
Learn about the lead researchers overseeing the trial and their institutional affiliations.
Johnson & Johnson Surgical Vision, Inc. Clinical Trial
Role: STUDY_DIRECTOR
Johnson & Johnson Surgical Vision, Inc.
Locations
Explore where the study is taking place and check the recruitment status at each participating site.
Shultz Chang Vision
Los Angeles, California, United States
Coastal Vision
Orange, California, United States
Pacific Eye Associates, A Medical Corporation
San Francisco, California, United States
Aloha Vision Consultants
Honolulu, Hawaii, United States
Parkhurst NuVision
San Antonio, Texas, United States
Countries
Review the countries where the study has at least one active or historical site.
Provided Documents
Download supplemental materials such as informed consent forms, study protocols, or participant manuals.
Document Type: Study Protocol
Document Type: Statistical Analysis Plan
Other Identifiers
Review additional registry numbers or institutional identifiers associated with this trial.
JJSV201EYST
Identifier Type: -
Identifier Source: org_study_id