The Effect of Increasing Current or Pulse Duration on Patient Movement and Intraoperative Transcranial Electric Stimulation Motor Evoked Potential Amplitude
NCT ID: NCT05375669
Last Updated: 2025-04-01
Study Results
The study team has not published outcome measurements, participant flow, or safety data for this trial yet. Check back later for updates.
Basic Information
Get a concise snapshot of the trial, including recruitment status, study phase, enrollment targets, and key timeline milestones.
COMPLETED
NA
31 participants
INTERVENTIONAL
2022-08-10
2024-11-01
Brief Summary
Review the sponsor-provided synopsis that highlights what the study is about and why it is being conducted.
When necessary, one can obtain larger MEPs by increasing current (I) or D to increase stimulus charge (Q = I × D). However, this also increases patient movement that can interfere with surgery and reduce MEP acquisition frequency.
The main research question is whether increasing current or pulse duration when applying intraoperative neuromonitoring produces less patient movement during surgery. As such, the IOM ISIS System will be employed for neuromonitoring and an accelerometer will be used to quantify patient movement.
The constant-current TES stimulators will be used in this study with a high-precision oscilloscope. Total intravenous anesthesia (TIVA), surgery and TES MEP monitoring will proceed routinely without modification and normally involves acquiring many MEPs over several hours. The only departure from standard care will be the placement of two small accelerometers and a brief MEP sequence before skin incision to determine chronaxie and compare the effect of an equivalent increase of I or D on MEP amplitude and movement.
Related Clinical Trials
Explore similar clinical trials based on study characteristics and research focus.
Optimization of Transcranial Motor Evoked Potentials in Supratentorial Surgeries
NCT06480370
Glutamate Modulation of tDCS Over Premotor Cortex Combined With Peripheral Nerve Stimulation Promoted Observation-execution-related Cortical Excitability and Motor Learning
NCT06694909
Non-pharmacologial, Non-invassive Intervention Before Cardiac Surgery: a Randomized Controlled Trial
NCT06791551
Effects of Different Intensities of Bilateral-transcranial Direct Current Stimulation in Healthy Individuals
NCT05929014
Neurophysiological Intraoperative or Epilepsy Monitoring
NCT01630785
Detailed Description
Dive into the extended narrative that explains the scientific background, objectives, and procedures in greater depth.
When necessary, one can obtain larger MEPs by increasing current (I) or D to increase stimulus charge (Q = I × D). However, this also increases patient movement that can interfere with surgery and reduce MEP acquisition frequency. Anecdotal observations suggest that increasing D may produce larger MEPs with less movement than increasing I, but there is no published support. If true, then the optimal D for monitoring may be above the chronaxie because less movement could facilitate more frequent MEP acquisition.
Finally, there is ongoing controversy about constant-current or constant-voltage TES. However, with stable resistance (R) there is no fundamental reason to prefer one or the other since they are related by Ohm's law I = V/R. Also, since threshold current and voltage vary with D their maximum levels should also vary with selected D, which could be confusing. Instead, because the International Electrotechnical Commission 50 mJ safety limit is based on energy (E = I2 × D × R = V2 × D/R), it may be more logical to apply constant-energy TES that would provide a consistent 0-50 mJ selection range at any selected D.
The primary objective is to assess whether intraoperative neuromonitoring with constant current or constant voltage produces less patient movement during surgery. The secondary objectives are to compare MEP amplitudes with the different setups, to estimate the true mean or median chronaxie and to develop the concept of constant-energy TES.
The main research question is whether increasing current or pulse duration when applying intraoperative neuromonitoring produces less patient movement during surgery. As such, the IOM ISIS System will be employed for neuromonitoring and an accelerometer will be used to quantify patient movement.
The constant-current TES stimulators will be used in this study with a high-precision oscilloscope. The calibration will assess 5-pulse trains with a 4 ms ISI and 100 mA output across a 1000 Ω resistor at 250, 500, and 1000 µs D. Measurements will include actual I and D of each pulse, and actual ISI.
Total intravenous anesthesia (TIVA), surgery and TES MEP monitoring will proceed routinely without modification and normally involves acquiring many MEPs over several hours. The only departure from standard care will be the placement of two small accelerometers and a brief MEP sequence before skin incision to determine chronaxie and compare the effect of an equivalent increase of I or D on MEP amplitude and movement.
Conditions
See the medical conditions and disease areas that this research is targeting or investigating.
Study Design
Understand how the trial is structured, including allocation methods, masking strategies, primary purpose, and other design elements.
NA
SINGLE_GROUP
TREATMENT
NONE
Study Groups
Review each arm or cohort in the study, along with the interventions and objectives associated with them.
ISIS IOM System
Total intravenous anesthesia (TIVA), surgery and TES MEP monitoring will proceed routinely without modification and normally involves acquiring many MEPs over several hours. The only departure from standard care will be the placement of two small accelerometers and a brief MEP sequence before skin incision to determine chronaxie and compare the effect of an equivalent increase of I or D on MEP amplitude and movement.
ISIS IOM System
The constant-current TES stimulators will be used in this study with a high-precision oscilloscope. The calibration will assess 5-pulse trains with a 4 ms ISI and 100 mA output across a 1000 Ω resistor at 250, 500, and 1000 µs D. Measurements will include actual I and D of each pulse, and actual ISI.
Total intravenous anesthesia (TIVA), surgery and TES MEP monitoring will proceed routinely without modification and normally involves acquiring many MEPs over several hours. The only departure from standard care will be the placement of two small accelerometers and a brief MEP sequence before skin incision to determine chronaxie and compare the effect of an equivalent increase of I or D on MEP amplitude and movement.
Interventions
Learn about the drugs, procedures, or behavioral strategies being tested and how they are applied within this trial.
ISIS IOM System
The constant-current TES stimulators will be used in this study with a high-precision oscilloscope. The calibration will assess 5-pulse trains with a 4 ms ISI and 100 mA output across a 1000 Ω resistor at 250, 500, and 1000 µs D. Measurements will include actual I and D of each pulse, and actual ISI.
Total intravenous anesthesia (TIVA), surgery and TES MEP monitoring will proceed routinely without modification and normally involves acquiring many MEPs over several hours. The only departure from standard care will be the placement of two small accelerometers and a brief MEP sequence before skin incision to determine chronaxie and compare the effect of an equivalent increase of I or D on MEP amplitude and movement.
Eligibility Criteria
Check the participation requirements, including inclusion and exclusion rules, age limits, and whether healthy volunteers are accepted.
Inclusion Criteria
* The patient has a supra- or infra-tentorial lesion requiring surgery
* The patient is undergoing neurosurgery with the use of Intraoperative Monitoring (IOM) during surgery to protect functional tissue
* The patient is older than 18 years
Exclusion Criteria
* Vulnerable subjects (pregnant women, pregnant, impaired consciousness)
* People who do not want to participate in the study
* Emergency procedures in which no consent was obtained before the operation
* Multiple surgeries on the same patient
* Preoperative non-affected arm motor deficit (MRC \<5), that is to say, no motor deficit of the arm ipsilateral to the surgery
* Inhalational anesthesia
* Persisting neuromuscular blockade
18 Years
ALL
No
Sponsors
Meet the organizations funding or collaborating on the study and learn about their roles.
Insel Gruppe AG, University Hospital Bern
OTHER
Responsible Party
Identify the individual or organization who holds primary responsibility for the study information submitted to regulators.
Principal Investigators
Learn about the lead researchers overseeing the trial and their institutional affiliations.
Kathleen Seidel, MMD
Role: PRINCIPAL_INVESTIGATOR
Inselspital Bern, Department of Neurosurgery
Locations
Explore where the study is taking place and check the recruitment status at each participating site.
Dep. of Neurosurgery, Bern University Hospital
Bern, , Switzerland
Countries
Review the countries where the study has at least one active or historical site.
References
Explore related publications, articles, or registry entries linked to this study.
Szelenyi A, Kothbauer KF, Deletis V. Transcranial electric stimulation for intraoperative motor evoked potential monitoring: Stimulation parameters and electrode montages. Clin Neurophysiol. 2007 Jul;118(7):1586-95. doi: 10.1016/j.clinph.2007.04.008. Epub 2007 May 15.
Abalkhail TM, MacDonald DB, AlThubaiti I, AlOtaibi FA, Stigsby B, Mokeem AA, AlHamoud IA, Hassounah MI, Baz SM, AlSemari A, AlDhalaan HM, Khan S. Intraoperative direct cortical stimulation motor evoked potentials: Stimulus parameter recommendations based on rheobase and chronaxie. Clin Neurophysiol. 2017 Nov;128(11):2300-2308. doi: 10.1016/j.clinph.2017.09.005. Epub 2017 Sep 28.
Macdonald DB, Skinner S, Shils J, Yingling C; American Society of Neurophysiological Monitoring. Intraoperative motor evoked potential monitoring - a position statement by the American Society of Neurophysiological Monitoring. Clin Neurophysiol. 2013 Dec;124(12):2291-316. doi: 10.1016/j.clinph.2013.07.025. Epub 2013 Sep 18.
MacDonald DB. Safety of intraoperative transcranial electrical stimulation motor evoked potential monitoring. J Clin Neurophysiol. 2002 Oct;19(5):416-29. doi: 10.1097/00004691-200210000-00005.
Eng J. Sample size estimation: how many individuals should be studied? Radiology. 2003 May;227(2):309-13. doi: 10.1148/radiol.2272012051.
Other Identifiers
Review additional registry numbers or institutional identifiers associated with this trial.
CCCV
Identifier Type: -
Identifier Source: org_study_id