Recruitment Status

UNKNOWN

Total Enrollment

50 participants

Study Classification

OBSERVATIONAL

Study Start Date

2022-02-28

Study Completion Date

2023-12-31

Brief Summary

Review the sponsor-provided synopsis that highlights what the study is about and why it is being conducted.

The aim of the study is to determine the correlation of the results of cardiac index (CI) measurements performed with use of bioreactance technology with the results of measurements made with the use of transpulmonary thermodilution. Both methods will be evaluated in reference to measurements based on echocardiography.

Detailed Description

Dive into the extended narrative that explains the scientific background, objectives, and procedures in greater depth.

After approval of the study design by the institutional ethics committee, 50 critically ill adult patients (requiring haemodynamic monitoring and mechanical ventilation) treated in the ICU for a intracranial pathology will be enrolled in the study.

Exclusions: Age under 18, presence of pleural effusion or pericardium (confirmed by chest X-ray and / or ultrasound / echocardiography), presence of aortic / mitral valve disease, presence of an implanted pacemaker CI measurements will be performed simultaneously for 5 minutes. The CI value measured by the transpulmonary thermodilution technique will be obtained with the PiCCO system (Pulsiocat PV8115; Pulsion Medical Systems, Feldkirchen, Germany). Measurements will be made three times within 5 minutes. For statistical purposes, the value of the arithmetic mean of the obtained results will be used.

The CI value as measured by the bioreactance method will be determined using the monitor: Starling Fluid Management System (Baxter International Inc, USA). This monitor uses bioreactance technology to determine hemodynamic parameters and bioimpedance technology to measure thoracic fluid content (TFC). The test data will be recorded with two pairs of electrodes placed on the chest according to the manufacturer's instructions. Measurements documented at 30-second intervals will concern 10 measurement cycles. The average of the obtained results will be subjected to statistical analysis.

Echocardiographic examination of the heart to determine the value of CI will be performed by one (always the same) qualified (certified in echocardiographic examinations) clinician.

Echocardiographic measurements will begin with determining the diameter of the left ventricular outflow tract (left ventricular outflow tract cross-sectional area, LVOT-CSA). Then, three subvalvular velocity time integral (LVOT-VTI) measurements will be made over the course of 5 minutes. This measurement will be performed in the apical five-chamber projection.

The stroke volume (SV) value will be calculated as: SV = LVOT-CSA x LVOT-VTI. The CI value will be calculated using the formula: CI = SV x heart rate (HR) / body surface area (BSA). The CI value archived for further statistical analysis will be the average of three measurements performed within 5 minutes.

Other variables that will be documented simultaneously with CI measurements: patient gender and weight, use of vasospastic / inotropic drugs (dose mcg / kg / min), positive end expiratory pressure (PEEP), presence of pulmonary hypertension.

Conditions

See the medical conditions and disease areas that this research is targeting or investigating.

Hemodynamic Instability

Study Design

Understand how the trial is structured, including allocation methods, masking strategies, primary purpose, and other design elements.

Observational Model Type

COHORT

Study Time Perspective

PROSPECTIVE

Eligibility Criteria

Check the participation requirements, including inclusion and exclusion rules, age limits, and whether healthy volunteers are accepted.

Inclusion Criteria

* 50 critically ill adult patients (requiring haemodynamic monitoring and mechanical ventilation) treated in the ICU for a intracranial pathology

Exclusion Criteria

* Age under 18
* Presence of pleural effusion or pericardium (confirmed by chest X-ray and / or ultrasound / echocardiography)
* Presence of aortic / mitral valve pathology
* Presence of an implanted pacemaker
Minimum Eligible Age

18 Years

Eligible Sex

ALL

Accepts Healthy Volunteers

No

Sponsors

Meet the organizations funding or collaborating on the study and learn about their roles.

University of Warmia and Mazury in Olsztyn

OTHER

Sponsor Role lead

Responsible Party

Identify the individual or organization who holds primary responsibility for the study information submitted to regulators.

Jan Adamski

Principal Investigator

Responsibility Role PRINCIPAL_INVESTIGATOR

Central Contacts

Reach out to these primary contacts for questions about participation or study logistics.

Jan Adamski, MD,PhD

Role: CONTACT

+48600700315

References

Explore related publications, articles, or registry entries linked to this study.

Geerts BF, Aarts LP, Jansen JR. Methods in pharmacology: measurement of cardiac output. Br J Clin Pharmacol. 2011 Mar;71(3):316-30. doi: 10.1111/j.1365-2125.2010.03798.x.

Reference Type BACKGROUND
PMID: 21284692 (View on PubMed)

Demiselle J, Mercat A, Asfar P. Is there still a place for the Swan-Ganz catheter? Yes. Intensive Care Med. 2018 Jun;44(6):954-956. doi: 10.1007/s00134-018-5158-0. Epub 2018 May 23. No abstract available.

Reference Type BACKGROUND
PMID: 29796915 (View on PubMed)

Kobe J, Mishra N, Arya VK, Al-Moustadi W, Nates W, Kumar B. Cardiac output monitoring: Technology and choice. Ann Card Anaesth. 2019 Jan-Mar;22(1):6-17. doi: 10.4103/aca.ACA_41_18.

Reference Type BACKGROUND
PMID: 30648673 (View on PubMed)

Keren H, Burkhoff D, Squara P. Evaluation of a noninvasive continuous cardiac output monitoring system based on thoracic bioreactance. Am J Physiol Heart Circ Physiol. 2007 Jul;293(1):H583-9. doi: 10.1152/ajpheart.00195.2007. Epub 2007 Mar 23.

Reference Type BACKGROUND
PMID: 17384132 (View on PubMed)

Squara P, Denjean D, Estagnasie P, Brusset A, Dib JC, Dubois C. Noninvasive cardiac output monitoring (NICOM): a clinical validation. Intensive Care Med. 2007 Jul;33(7):1191-1194. doi: 10.1007/s00134-007-0640-0. Epub 2007 Apr 26.

Reference Type BACKGROUND
PMID: 17458538 (View on PubMed)

Raval NY, Squara P, Cleman M, Yalamanchili K, Winklmaier M, Burkhoff D. Multicenter evaluation of noninvasive cardiac output measurement by bioreactance technique. J Clin Monit Comput. 2008 Apr;22(2):113-9. doi: 10.1007/s10877-008-9112-5. Epub 2008 Mar 14.

Reference Type BACKGROUND
PMID: 18340540 (View on PubMed)

Porter TR, Shillcutt SK, Adams MS, Desjardins G, Glas KE, Olson JJ, Troughton RW. Guidelines for the use of echocardiography as a monitor for therapeutic intervention in adults: a report from the American Society of Echocardiography. J Am Soc Echocardiogr. 2015 Jan;28(1):40-56. doi: 10.1016/j.echo.2014.09.009. No abstract available.

Reference Type BACKGROUND
PMID: 25559474 (View on PubMed)

Malik SB, Chen N, Parker RA 3rd, Hsu JY. Transthoracic Echocardiography: Pitfalls and Limitations as Delineated at Cardiac CT and MR Imaging. Radiographics. 2017 Mar-Apr;37(2):383-406. doi: 10.1148/rg.2017160105. Epub 2017 Feb 17.

Reference Type BACKGROUND
PMID: 28212053 (View on PubMed)

Ling HZ, Gallardo-Arozena M, Company-Calabuig AM, Nicolaides KH, Kametas NA. Clinical validation of bioreactance for the measurement of cardiac output in pregnancy. Anaesthesia. 2020 Oct;75(10):1307-1313. doi: 10.1111/anae.15110. Epub 2020 May 29.

Reference Type BACKGROUND
PMID: 32469423 (View on PubMed)

Lamia B, Kim HK, Severyn DA, Pinsky MR. Cross-comparisons of trending accuracies of continuous cardiac-output measurements: pulse contour analysis, bioreactance, and pulmonary-artery catheter. J Clin Monit Comput. 2018 Feb;32(1):33-43. doi: 10.1007/s10877-017-9983-4. Epub 2017 Feb 10.

Reference Type BACKGROUND
PMID: 28188408 (View on PubMed)

Other Identifiers

Review additional registry numbers or institutional identifiers associated with this trial.

UWMOlsztyn

Identifier Type: -

Identifier Source: org_study_id

More Related Trials

Additional clinical trials that may be relevant based on similarity analysis.

Guided Placement of CRT-Leads
NCT00764075 COMPLETED NA