Study Results
The study team has not published outcome measurements, participant flow, or safety data for this trial yet. Check back later for updates.
Basic Information
Get a concise snapshot of the trial, including recruitment status, study phase, enrollment targets, and key timeline milestones.
UNKNOWN
100 participants
OBSERVATIONAL
2022-02-01
2024-06-30
Brief Summary
Review the sponsor-provided synopsis that highlights what the study is about and why it is being conducted.
Related Clinical Trials
Explore similar clinical trials based on study characteristics and research focus.
Comparison of Two Monitors That Measure Neuromuscular Function During Surgeries
NCT03987607
"Electromagnetical Stimulation of Phrenic Nerve to Generate Contraction of the Diaphragm"
NCT04884698
Mindray Neuromuscular Transmission Transducer
NCT02892045
Effects of taVNS on Postoperative Pain in Complex Spinal Surgery
NCT07330973
Determination of Target of Adequate Partial Neuromuscular Blockade for Electrophysiologic Monitoring During Microvascular Decompression Surgery
NCT01613781
Detailed Description
Dive into the extended narrative that explains the scientific background, objectives, and procedures in greater depth.
Stimpod NMS 450 or other related Stimpod device (Xavant Technology, Pretoria, South Africa)--acceleromyography and/or electromyography. Movement of the thumb and hand will not be restricted and no artificial preload will be used. Electrodes (3M Red Dot, 3M Healthcare, St. Paul, MN, USA) will be applied over the ulnar nerve at the wrist for acceleromyography. The Stimpod acceleromyography sensor will be attached to the distal phalanx of the thumb using the supplied plastic circumferential band, reinforced with tape if necessary. The Stimpod electromyography printed electrode array will be applied as described in the manufacturer's instructions for use.
TwitchView Monitor (Blink Device Company, Seattle, WA, USA)--electromyography. The TwitchView electromyography printed electrode array will be applied as described in the manufacturer's instructions for use.
TetraGraph (Senzime, Sweden)--electromyography. The TetraGraph electromyography printed electrode array will be applied as described in the manufacturer's instructions for use.
Nihon Kohden (Japan)--electromyography. The Nihon Kohden printed electromyography electrode array will be applied as described in the manufacturer's instructions for use.
Mechanomyography. The mechanomyography monitors were built in our laboratory and consists of a force transducer, signal amplifier and analogue to digital converter held in a 3D printed wrist and hand immobilizer, or other hand immobilizer rig. The mechanomyography force transducer response is linear with precision to 5g and accuracy to 25g for measurements examined from 0 to 5kg with sensitivity to 10g within that range. A preload of 200-300g will applied to the thumb prior to data collection. Custom software using the LabVIEW package (National Instruments, Austin, Texas) was developed for data acquisition, analysis of the voltage response after the train-of-four stimulus and for counting the twitches.
General experimental conditions. The amplitude of the train of four stimulus will be set at 60 mA in all cases. Skin prep with alcohol wipes will be performed prior to attaching any electrodes. Temperature homeostasis will be maintained in all patients through the use of active warming. Normocarbia will be maintained as defined by end tidal CO2 between approximately 32 and 40 mmHg. The anesthesia technique including the choice of anesthetic and neuromuscular blocking agents will be at the discretion of the anesthesia care team and may include propofol, opioids (mainly fentanyl and hydromorphone), sevoflurane, isoflurane, rocuronium and vecuronium. Data collection will be customized in each patient depending upon the availability of upper limbs for monitoring. Acceleromyography and mechanomyography cannot be tested on the same arm simultaneously because the mechanomyography restricts movement of the thumb. The electromyography electrode array does not interfere with simultaneously measuring either acceleromyography or mechanomyography. Subjective twitch count can be made on the same hand as the acceleromyography or electromyography measurement, but not on the same hand as mechanomyography since the plastic frame or other rig of the mechanomyography precludes manual palpation of thumb movement. Train-of- four count will be measured by palpation (when possible) and then by one or more of the twitch monitors (i.e. two measurements were taken within the span of about 2 minutes) approximately every 5 minutes from induction of anesthesia until just before emergence from anesthesia. Measurements will not be made for 10 minutes following administration of neuromuscular blocking drugs or reversal agents in order to avoid periods when the extent of neuromuscular blockade was changing very rapidly. When measurements were made on both arms, the train of four twitch stimulus will be administered in each arm within about 2 minutes. Not all twitch monitoring devices we be evaluated in each patient. The choice of devices to be evaluated in each patient will be made primarily on the basis of the availability of arms for monitoring and the availability of monitoring devices.
Conditions
See the medical conditions and disease areas that this research is targeting or investigating.
Study Design
Understand how the trial is structured, including allocation methods, masking strategies, primary purpose, and other design elements.
CASE_ONLY
PROSPECTIVE
Study Groups
Review each arm or cohort in the study, along with the interventions and objectives associated with them.
Twitch Monitoring
Patients undergoing surgery with general anesthesia requiring neuromuscular blockade.
Mechanomyograph Twitch Monitor
Measurement of train-of-four count and ratio and post tetanic count
Stimpod Twitch Monitor
Measurement of train-of-four count and ratio and post tetanic count
TetraGraph Twitch Monitor
Measurement of train-of-four count and ratio and post titanic count
TwitchView Twitch Monitor
Measurement of train-of-four count and ratio and post tetanic count
Nihon Kohden Twitch Monitor
Measurement of train-of-four count and ratio and post tetanic count
Palpation of twitch count
The train-of-four count is determined by manual palpation of the evoked twitch response
Interventions
Learn about the drugs, procedures, or behavioral strategies being tested and how they are applied within this trial.
Mechanomyograph Twitch Monitor
Measurement of train-of-four count and ratio and post tetanic count
Stimpod Twitch Monitor
Measurement of train-of-four count and ratio and post tetanic count
TetraGraph Twitch Monitor
Measurement of train-of-four count and ratio and post titanic count
TwitchView Twitch Monitor
Measurement of train-of-four count and ratio and post tetanic count
Nihon Kohden Twitch Monitor
Measurement of train-of-four count and ratio and post tetanic count
Palpation of twitch count
The train-of-four count is determined by manual palpation of the evoked twitch response
Eligibility Criteria
Check the participation requirements, including inclusion and exclusion rules, age limits, and whether healthy volunteers are accepted.
Inclusion Criteria
2. Undergoing anesthesia that requires neuromuscular blocking drugs
Exclusion Criteria
2. Undergoing anesthesia that does not require neuromuscular blocking drugs
3. Undergoing a procedure in which access to one or both arms is limited
4. Anatomical abnormalities of the hands or arms that preclude twitch monitoring with ulnar nerve stimulation and evoked thumb twitch response
18 Years
100 Years
ALL
No
Sponsors
Meet the organizations funding or collaborating on the study and learn about their roles.
University of Washington
OTHER
Responsible Party
Identify the individual or organization who holds primary responsibility for the study information submitted to regulators.
T. Andrew Bowdle
Professor, School of Medicine
Principal Investigators
Learn about the lead researchers overseeing the trial and their institutional affiliations.
T. Andrew Bowdle, MD, PhD
Role: PRINCIPAL_INVESTIGATOR
University of Washington
Locations
Explore where the study is taking place and check the recruitment status at each participating site.
University of Washington Medical Center
Seattle, Washington, United States
Countries
Review the countries where the study has at least one active or historical site.
Central Contacts
Reach out to these primary contacts for questions about participation or study logistics.
Facility Contacts
Find local site contact details for specific facilities participating in the trial.
References
Explore related publications, articles, or registry entries linked to this study.
Bowdle A, Bussey L, Michaelsen K, Jelacic S, Nair B, Togashi K, Hulvershorn J. Counting train-of-four twitch response: comparison of palpation to mechanomyography, acceleromyography, and electromyography. Br J Anaesth. 2020 Jun;124(6):712-717. doi: 10.1016/j.bja.2020.02.022. Epub 2020 Mar 28.
Bowdle A, Bussey L, Michaelsen K, Jelacic S, Nair B, Togashi K, Hulvershorn J. A comparison of a prototype electromyograph vs. a mechanomyograph and an acceleromyograph for assessment of neuromuscular blockade. Anaesthesia. 2020 Feb;75(2):187-195. doi: 10.1111/anae.14872. Epub 2019 Oct 16.
Wedemeyer Z, Jelacic S, Michaelsen K, Silliman W, Togashi K, Bowdle A. Comparative performance of stimpod electromyography with mechanomyography for quantitative neuromuscular blockade monitoring. J Clin Monit Comput. 2024 Feb;38(1):205-212. doi: 10.1007/s10877-023-01087-1. Epub 2023 Oct 13.
Other Identifiers
Review additional registry numbers or institutional identifiers associated with this trial.
STUDY00001561
Identifier Type: -
Identifier Source: org_study_id
More Related Trials
Additional clinical trials that may be relevant based on similarity analysis.