Occlusal Relationship Assesment of Monolithic Zirconia FDPs
NCT ID: NCT04855084
Last Updated: 2021-04-22
Study Results
The study team has not published outcome measurements, participant flow, or safety data for this trial yet. Check back later for updates.
Basic Information
Get a concise snapshot of the trial, including recruitment status, study phase, enrollment targets, and key timeline milestones.
COMPLETED
NA
14 participants
INTERVENTIONAL
2018-05-24
2018-08-27
Brief Summary
Review the sponsor-provided synopsis that highlights what the study is about and why it is being conducted.
One investigator (DK) was assigned to prepare the restoration sites and deliver the FDPs. All monolithic Zr and all metal-ceramic FDPs were designed and fabricated by the same experienced dental technician. One investigator (HL), that was not involved in the treatment intervention was assigned to make the 3D analysis of the volumetric occlusal adjustment amount.
Related Clinical Trials
Explore similar clinical trials based on study characteristics and research focus.
Clinical Evaluation of Monolithic Zirconia FPDs
NCT04879498
Metal-ceramic Fixed Partial Dentures Fabricated With Laser Sintering
NCT06242639
Abutment Analysis of Metallic Denture Frameworks in Mandibular Kenedy Class III Cases
NCT07215208
Clinical Assessment of CAD/CAM Monolithic Complete Denture
NCT07091552
Combined Tooth-implant Supported Prostheses
NCT05712031
Detailed Description
Dive into the extended narrative that explains the scientific background, objectives, and procedures in greater depth.
The control group FDPs (metal-ceramic) will be fabricated with a complete analog workflow. Accordingly, a polyether dual-phase impression (Impregum Penta Soft Quick and Soft Quick, 3M) will be taken from the restoration arch and a Polyvinylsiloxane (PVS) impression material will be used for the impression of the antagonist arch. Face bow transfer (Whip Mix Face bow0 will be done. Following the stone master model (Type IV dental rock, Fuji) obtention, the maxillary models will be mounted to a semi-adjustable articulator based on the face bow record and mandibular models will be then mounted with the aid of laterotrusive and MI records. The MI and laterotrusive records will be taken with a PVS bite registration material. The Cr-Ni frameworks will be fabricated with lost-wax technique (Brand?), manually layered with feldspathic veneering porcelain (Vita), and glazed by one experienced dental technician.
The test group FDPs (high translucent monolithic Zr) (Aidite Multilayer 3D) will be fabricated by a complete/model-free digital workflow. The digital quadrant impressions of the preparation, antagonist as well as bite registration will be obtained by the use of an IOS (Trios 3, 3Shape). The files will be sent to a CAD software (Dental System, 3Shape) directly via the communication tool (3 Shape Communicate, 3Shape). Following CAD, the high translucent monolithic Zr 3-unit FDPs will be computer-aided manufactured (CORITEC 350i Loader, imes-icore GmbH). FDPs will be high-gloss polished, glazed, and sent to the dental clinic for the try-in session. Monolithic Zr design and manufacturing process will be completed by one dental technician that is highly experienced in CAD/CAM.
Clinical occlusal adjustment:
A standardized occlusal adjustment strategy will be adopted and executed by one investigator for both control and test group FDPs. In half of the restoration sites, monolithic Zr restorations will be the ones to have been tried first whereas in the other half metal-ceramic FDPs were the first. Initially, distal and mesial approximal contact areas, then the internal fit will be checked and adjusted to eliminate any interferences in order to ensure the optimal fitting of the restorations. For the occlusal adjustment amount calculation, the FDPs will be fixed on the prepared teeth provisionally and scanned by an IOS (Trios 3, 3Shape) to record the pre-adjustment FDP volume. The occlusal contacts and adjustment needs were assessed while still the restorations are fixed. The occlusal adjustment strategy will be as follows: Under normal occlusal forces, 40-micron articulation paper (Arti-Check micro-thin, Bausch, Cologne, Germany) will be used and followed by 12-micron articulation foil (Shimstock-foil, Bausch, Cologne, Germany) under strong occlusal force. The FDPs' occlusal contact design will be ensured to hold the articulation foil under strong occlusal force. Thereafter, once ensuring the FDPs to remain fixed, intraoral digital quadrant impressions (Trios 3, 3 Shape) will be taken by the same investigator in order to record the post-adjustment volume of the FDPs. After chairside finishing and polishing of the adjustment areas, Monolithiz Zr FDPs will be adhesively luted by a composite cement as the definitive restoration.
2.4. Quantitative analysis Both .stl files (pre-and-post adjustment) will be exported in order to process in an inspection software (Gom Inspect 2019, GOM GmbH, Braunschweig, Germany). The pre-and post-adjustment .stl files will be superimposed with the surface of restorations excluding occlusal adjusted area. After that, they will be sectioned from the same planes, mesial, distal, and 3mm apical to occlusal plane. The total volume of the sections that will be analyzed will be measured and the quantitative volume difference of the sectioned parts then was Calculated three-dimensionally (3Matic, Materialise NV, Leuven, Belgium). The total volumetric difference in mm3 between pre-and post-adjustment .stl files will be calculated for each 3-unit FDP
Conditions
See the medical conditions and disease areas that this research is targeting or investigating.
Study Design
Understand how the trial is structured, including allocation methods, masking strategies, primary purpose, and other design elements.
NON_RANDOMIZED
PARALLEL
TREATMENT
DOUBLE
Study Groups
Review each arm or cohort in the study, along with the interventions and objectives associated with them.
Complete Digital Fixed Dental Prosthesis
Following the Digital Impression using 3 Shape Trios Intraoral scanner, digital design, and manufacturing of the Monolithic Zirconia FDPs.
Monolithic FDPs: before adjustment
Using Intraoral Scanner, occlusal relationship assessment of the Monolithic FDPs before the occlusal adjustment.
Monolithic FDPs: after adjustment
Using Intraoral Scanner, occlusal relationship assessment of the Monolithic FDPs after the occlusal adjustment.
Monolithic FDPs: before adjustment
Before the occlusal adjustment, Occlusal relationship recording of the 3-unit monolithic FDPs which was fabricated following the complete digital work-flow.
Monolithic FDPs: after adjustment
After the occlusal adjustment, Occlusal relationship recording of the 3-unit monolithic FDPs which was fabricated following the complete digital work-flow.
Metal fused porcelain FDPs: before adjustment
Before the occlusal adjustment, Occlusal relationship recording of the 3-unit metal fused porcelain FDPs which was fabricated following the complete conventional manufacturing procedure.
Metal fused porcelain FDPs: after adjustment
After the occlusal adjustment, digital occlusal relationship recording was done of the 3-unit metal fused porcelain FDPs which was fabricated following the complete conventional manufacturing procedure.
Analog Fixed Dental Prosthesis
Following the Conventional Impression, transfer to the articulator with Face bow. Manufacturing of the FDPs with lost wax technique and veneering.
Metal fused porcelain FDPs: before adjustment
Using Intraoral Scanner, occlusal relationship assessment of the metal fused to porcelain FDPs before the occlusal adjustment.
Metal fused porcelain FDPs: after adjustment
Using Intraoral Scanner, occlusal relationship assessment of the metal fused to porcelain FDPs after the occlusal adjustment.
Monolithic FDPs: before adjustment
Before the occlusal adjustment, Occlusal relationship recording of the 3-unit monolithic FDPs which was fabricated following the complete digital work-flow.
Monolithic FDPs: after adjustment
After the occlusal adjustment, Occlusal relationship recording of the 3-unit monolithic FDPs which was fabricated following the complete digital work-flow.
Metal fused porcelain FDPs: before adjustment
Before the occlusal adjustment, Occlusal relationship recording of the 3-unit metal fused porcelain FDPs which was fabricated following the complete conventional manufacturing procedure.
Metal fused porcelain FDPs: after adjustment
After the occlusal adjustment, digital occlusal relationship recording was done of the 3-unit metal fused porcelain FDPs which was fabricated following the complete conventional manufacturing procedure.
Interventions
Learn about the drugs, procedures, or behavioral strategies being tested and how they are applied within this trial.
Monolithic FDPs: before adjustment
Before the occlusal adjustment, Occlusal relationship recording of the 3-unit monolithic FDPs which was fabricated following the complete digital work-flow.
Monolithic FDPs: after adjustment
After the occlusal adjustment, Occlusal relationship recording of the 3-unit monolithic FDPs which was fabricated following the complete digital work-flow.
Metal fused porcelain FDPs: before adjustment
Before the occlusal adjustment, Occlusal relationship recording of the 3-unit metal fused porcelain FDPs which was fabricated following the complete conventional manufacturing procedure.
Metal fused porcelain FDPs: after adjustment
After the occlusal adjustment, digital occlusal relationship recording was done of the 3-unit metal fused porcelain FDPs which was fabricated following the complete conventional manufacturing procedure.
Eligibility Criteria
Check the participation requirements, including inclusion and exclusion rules, age limits, and whether healthy volunteers are accepted.
Inclusion Criteria
2. Participants over 20 years old with no contradiction of dental treatment.
3. Good oral hygiene habits, healthy periodontal status, no sign of bruxism (e.g. attrition score \>2 according to Wigdorowicz-Makowerowa, and/or muscle pain), and no self-reported grinding and/or clenching.
1. No visible periapical lesion
2. Presence of minimum 1:1 crown/root ratio
3. Class I mobility (Nyman \& Lindhe 2003)
4. No probing depth more than 4mm
5. Presence of natural opposing teeth with no restorative treatment.
6. Presence of a stable maximum intercuspation (MI) relationship
20 Years
75 Years
ALL
Yes
Sponsors
Meet the organizations funding or collaborating on the study and learn about their roles.
Hacettepe University
OTHER
Duygu Karasan
OTHER
Responsible Party
Identify the individual or organization who holds primary responsibility for the study information submitted to regulators.
Duygu Karasan
Research Asistant, DDS, PhD
Principal Investigators
Learn about the lead researchers overseeing the trial and their institutional affiliations.
Duygu Karasan, PhD
Role: PRINCIPAL_INVESTIGATOR
Hacettepe University
Locations
Explore where the study is taking place and check the recruitment status at each participating site.
Hacettepe University Faculty of Dentistry
Ankara, , Turkey (Türkiye)
Countries
Review the countries where the study has at least one active or historical site.
Other Identifiers
Review additional registry numbers or institutional identifiers associated with this trial.
KA-180043
Identifier Type: -
Identifier Source: org_study_id
More Related Trials
Additional clinical trials that may be relevant based on similarity analysis.