Fluid Responsiveness: SVV vs esSVV in Mechanically Ventilated and Spontaneously Breathing Patients
NCT ID: NCT04786652
Last Updated: 2024-03-22
Study Results
The study team has not published outcome measurements, participant flow, or safety data for this trial yet. Check back later for updates.
Basic Information
Get a concise snapshot of the trial, including recruitment status, study phase, enrollment targets, and key timeline milestones.
COMPLETED
NA
32 participants
INTERVENTIONAL
2021-03-20
2021-12-01
Brief Summary
Review the sponsor-provided synopsis that highlights what the study is about and why it is being conducted.
All the measurements and tests will be performed:
1. In mechanically ventilated patients after OPCAB within two hrs after intervention: passive leg raising (PLR), increased PEEP, and mini-fluid load (mFL) tests will be followed by standard fluid load (sFL). Monitoring: SVVPCA, PPVPCA, esSVV, HLI, PVI, pre-ejection fraction (PEP, echocardiography), CIPCA, esCI and CISTD. Transthoracic echocardiography will be performed to assess the volume of heart chambers, ejection fraction and pre-ejection phase (PEP).
2. In spontaneously breathing patients at 18 hrs of the postoperative period: PLR, and mFL tests followed by sFL. Monitoring: SVVPCA, PPVPCA, esSVV, PVI, PEP, CIPCA, esCI and CISTD. Transthoracic echocardiography will be performed to assess the volume of heart chambers, ejection fraction and pre-ejection phase.
Related Clinical Trials
Explore similar clinical trials based on study characteristics and research focus.
Dynamic Tests and Parameters to Predict Fluid Responsiveness After OPCAB
NCT04482946
Effect of Wide Pulse Pressure on the Predictability of Stroke Volume Variation for Fluid Responsiveness in Patients Undergoing Off-pump Coronary Artery Bypass Graft
NCT01404455
Pulse Pressure Variation (PPV) to Predict Fluid Responsiveness During Cardiac Displacement in Patients Undergoing Off-pump Coronary Artery Bypass Surgery (OPCAB)
NCT01041742
Non-invasive Prediction of Fluid and Noradrenaline Responsiveness Using the Carotid Wave Intensity.
NCT06197321
Reliability of a New Pulse Contour Technique for Diagnosing an Increase in Stroke Volume During a Fluid Challenge for Hemodynamic Optimization in Patients Scheduled for High-risk Abdominal Surgery: Comparison With Transthoracic Echocardiography: COMPARE Study
NCT04871620
Detailed Description
Dive into the extended narrative that explains the scientific background, objectives, and procedures in greater depth.
Among emerging techniques for continuous measurement of SVV and cardiac output, the assessment of pulse wave transit time (PWTT) has recently become available in the clinical practice. The latter method is based on the relationship between R-wave on ECG, SpO2, and blood pressure, allowing assessment of estimated continuous stroke volume, SVV and CO (esSVV and esCCO, Nihon Kohden, Japan). The potential advantage of this technique is relative non-invasiveness. However, possible limitations include the dependence on signal quality, calibration and intrinsic hemodynamic characteristics. The results of our pilot study of esCCO in OPCAB demonstrate that during OPCAB, esCCO values overestimate CO and demonstrate poor accuracy, precision, and trending ability compared to transpulmonary thermodilution (TPTD). However, postoperatively esCCO showed better agreement with TPTD. The determination of esSVV when CO2 is measured on the bedside monitor also requires further validation in changing clinical settings both during mechanical ventilation and spontaneous breathing.
Goals of the study The primary goal of this study is to assess the accuracy of estimated stroke volume variation (esSVV, Nihon Kohden, Japan) compared with SVV determined by conventional pulse contour analysis (SVVPCA), respectively.
The secondary goals of this study are to assess the predictive value of esSVV in the early postoperative period during complex dynamic tests including series of dynamic tests (passive leg raising, increased PEEP, and mini-fluid load) followed by the standard fluid load in both mechanically ventilated and spontaneously breathing patients.
Methods Before OPCAB, after receiving the informed consent, all the patients will be subjected to standard premedication. After transfer to the operation room, the catheterization of radial artery using standard 20 G radial arterial catheter (Arteriofix, B/Braun, Germany) and peripheral vein will be performed before induction of anesthesia. The monitoring will also include ECG and SpO2.
After standardized preoxygenation 80% O2 for 3 minutes the induction of anesthesia will be conducted using propofol 1-1.5 mg/kg, fentanyl 5-7 mcg/kg and pipecuronium 0.1 mg/kg. Thereafter anesthesia will be maintained with sevoflurane 0.5-3 vol.% with flow of 1 l/min and fentanyl infusion of 2-4 mcg/kg/hr. EtCO2 will be monitored throughput the study period using BSM9100 monitor (Nihon Kohden, Japan).
All patients will be mechanically ventilated using volume controlled ventilation (Primus, Dräger, Germany) with FiO2 0.5, PEEP 5 cm H2O, VT 8 ml/kg PBW, and RR between 10 to 18 per min to maintain EtCO2 30-35 mm Hg. After induction of anesthesia, the femoral artery will be catheterized with a 5F arterial thermodilution catheter (Pulsiocath PV2015L20, Pulsion). An 8.5F 20-cm central venous catheter will be inserted into the internal jugular vein. The thermodilution measurements will be performed in triplicate with a cooled (\< 8°C) 0.9% NaCl solution injected via the central venous catheter. To maintain their fluid status, the patients will receive continuous infusion of balanced crystalloid solutions using infusomate (B\|Braun) at the rate depending on initial global end-diastolic volume index (GEDVI) value:
* GEDI \< 650 ml/m2 - 7 ml/kg/hr.
* GEDI = 651-750 ml/m2 - 5 ml/kg/hr.
* GEDI \> 750 ml/m2 - 3 ml/kg/hr. In cases of arterial hypotension (mean arterial pressure \< 60 mm Hg for longer than 5 mins) despite fluid repletion the norepinephrine infusion will be started. Goal-directed inotrope (dobutamine) and/or vasopressor (noradrenaline) support is to be used in case of cardiac index \< 2.0 l/min/m2 (PiCCO2) and MAP \< 60 mm Hg for more than 5 min, respectively.
All hemodynamic parameters will be electronically captured (PiCCO2 Science Version and Nihon Kohden BSM 9100). The calibration of esCCO will be performed using invasive blood pressure and patient data after transfer to ICU. In addition, all patients will be monitored for respiratory mechanics, arterial and venous blood gases and lactate concentration, EtCO2, SpO2, and depth of anesthesia (BIS monitoring). In addition, all the data retrieved from PiCCO2 and esCCO will be electronically captured constantly with a predefined frequency.
After the intervention, all the patients will be transferred to the cardiosurgical ICU and sedated with propofol (2-6 mg/kg/hr) during 30-60 min to prevent early emergence and facilitate the assessment of fluid responsiveness and effects of recruitment maneuver and fluid load tests. All patients will be ventilated in the IPPV volume-controlled mode with FiO2 0.5, PEEP 5 cm H2O, VT 8 ml/kg PBW, and RR between 10 to 18 per min to maintain EtCO2 30-45 mm Hg. The fluid therapy will include balanced crystalloid infusion at rates of 2-3 ml/kg/hr during the first 6 hrs postoperatively.
All the measurements and tests will be performed:
1. In mechanically ventilated patients after OPCAB within two hrs after intervention: passive leg raising (PLR), increased PEEP, and mini-fluid load (mFL) tests will be followed by the standard fluid load (sFL). Monitoring: SVVPCA, PPVPCA, esSVV, HLI, PVI, the pre-ejection fraction (PEP, echocardiography), CIPCA, esCI and CISTD. Transthoracic echocardiography will be performed to assess the volume of heart chambers, ejection fraction and pre-ejection phase (PEP).
2. In spontaneously breathing patients at 18 hrs of the postoperative period: PLR, and mFL tests followed by sFL. Monitoring: SVVPCA, PPVPCA, esSVV, PVI, PEP, CIPCA, esCI and CISTD. Transthoracic echocardiography will be performed to assess the volume of heart chambers, ejection fraction and pre-ejection phase.
Dynamic tests Passive leg raising (PLR) test will be performed by transient transferring of the patient from a classic semi-recumbent position to elevated legs and horizontal trunk position for 2 minutes. The effect will be assessed at 60 seconds after start of the test.3,4 The PEEP-test (in mechanically ventilated patients only) with PEEP increased from 5 to 20 cm H2O for five minutes will be performed. The PEEP test will be discontinued in case of MAP reduction below 50 mm Hg and/or bradycardia (below 40/min) or PCCI \< 1.5 l/min/m2 during the period exceeding one minute. The measurements will be registered at 2 and 5 min after the start of PEEP test.10 Mini-FLT (mFLT) of 1.5 ml/kg crystalloid within 1 min (approx. 100 mL).11,12 Standard FLT (5.5 mL/kg) within 5 min (approx. 400 mL). Both tests will be followed by the registration of PCA-based CI, SVV, and PPV and PWTT-based esSVV and esCCO. The patient will be assigned as "fluid responsive" if the standard fluid load test results in 15% increase in CO determined with STD.12 The predictive value of complex dynamic test comprising PLR, PEEP, and mFL tests will be explored and merged into one complex score.
Postoperative infusion After sFL-test, the infusion will be maintained at rate of 1 ml/kg in fluid responders (an increase of CI \> 15% after standard fluid load) and 0.5 ml/kg/hr in non-responders using standard infusomate for titration (B\|Braun).
We plan to enroll 20 patients. The predictive value of esSVV for fluid responsiveness during postoperative period will be assessed using ROC-analysis and compared with other functional tests. The accuracy of esSVV measurements will be assessed using Pearson's or Spearman's correlation coefficients and Bland-Altman analysis using PCA-based SVV values and STD-based CO values as reference techniques.
For SVV, the percentage error (PE) will be calculated as (1.96 × SD of the bias of the methods / mean SVV of the two methods × 100%).
Following the calculation of delta CO (ΔCO) between two consecutive measurements for both methods by subtracting the value of preceding stage from that of the consequent stage, a half-circle polar plot will be made. According to Critchley et al., central zone data with mean ΔCO \< 10% representing statistical noise component will be excluded from further analysis. Based on polar data, angular bias, radial limits of agreement and polar concordance rate will be calculated. A trending ability will be assumed as good if angular bias will be within ± 5°, radial limits of agreement within ± 30° and polar concordance rate at 30° will be 95% or higher. For all the tests a p value \< 0.05 will be considered as significant.
Conditions
See the medical conditions and disease areas that this research is targeting or investigating.
Study Design
Understand how the trial is structured, including allocation methods, masking strategies, primary purpose, and other design elements.
NA
SINGLE_GROUP
DIAGNOSTIC
NONE
Study Groups
Review each arm or cohort in the study, along with the interventions and objectives associated with them.
Assessment of fluid responsiveness
estimated stroke volume variation (esSVV, Nihon Kohden, Japan)
Assessment of the estimated stroke volume variation (esSVV, Nihon Kohden, Japan) in the early postoperative period after OPCAB
Assessment of fluid responsiveness in mechanically ventilated patients after OPCAB
In mechanically ventilated patients after OPCAB within two hrs after intervention: passive leg raising (PLR), increased PEEP, and mini-fluid load (mFL) tests will be followed by standard fluid load (sFL). Monitoring: SVVPCA, PPVPCA, esSVV, HLI, PVI, pre-ejection fraction (PEP, echocardiography), CIPCA, esCI and CISTD. Transthoracic echocardiography will be performed to assess the volume of heart chambers, ejection fraction and pre-ejection phase (PEP).
Assessment of fluid responsiveness in spontaneously breathing patients at 18 hrs of the postoperative period
2\) In spontaneously breathing patients at 18 hrs of the postoperative period: PLR, and mFL tests followed by sFL. Monitoring: SVVPCA, PPVPCA, esSVV, PVI, PEP, CIPCA, esCI and CISTD. Transthoracic echocardiography will be performed to assess the volume of heart chambers, ejection fraction and pre-ejection phase.
Interventions
Learn about the drugs, procedures, or behavioral strategies being tested and how they are applied within this trial.
estimated stroke volume variation (esSVV, Nihon Kohden, Japan)
Assessment of the estimated stroke volume variation (esSVV, Nihon Kohden, Japan) in the early postoperative period after OPCAB
Assessment of fluid responsiveness in mechanically ventilated patients after OPCAB
In mechanically ventilated patients after OPCAB within two hrs after intervention: passive leg raising (PLR), increased PEEP, and mini-fluid load (mFL) tests will be followed by standard fluid load (sFL). Monitoring: SVVPCA, PPVPCA, esSVV, HLI, PVI, pre-ejection fraction (PEP, echocardiography), CIPCA, esCI and CISTD. Transthoracic echocardiography will be performed to assess the volume of heart chambers, ejection fraction and pre-ejection phase (PEP).
Assessment of fluid responsiveness in spontaneously breathing patients at 18 hrs of the postoperative period
2\) In spontaneously breathing patients at 18 hrs of the postoperative period: PLR, and mFL tests followed by sFL. Monitoring: SVVPCA, PPVPCA, esSVV, PVI, PEP, CIPCA, esCI and CISTD. Transthoracic echocardiography will be performed to assess the volume of heart chambers, ejection fraction and pre-ejection phase.
Eligibility Criteria
Check the participation requirements, including inclusion and exclusion rules, age limits, and whether healthy volunteers are accepted.
Inclusion Criteria
* Age \> 18 years and \< 80 yrs.
* Preoperative echocardiographic ejection fraction \> 0.35
Exclusion Criteria
* Significant peripheral arteriopathy.
* Constant form of atrial fibrillation.
* Pacemaker
* Severe valve dysfunction.
* The surgical requirement to harvest both radial arteries.
* Intra-aortic balloon pump.
* Transfer to cardiopulmonary bypass (on-pump CABG).
18 Years
80 Years
ALL
No
Sponsors
Meet the organizations funding or collaborating on the study and learn about their roles.
Nihon Kohden
INDUSTRY
Northern State Medical University
OTHER
Responsible Party
Identify the individual or organization who holds primary responsibility for the study information submitted to regulators.
Locations
Explore where the study is taking place and check the recruitment status at each participating site.
City hospital # 1 / Northern State Medical University,
Arkhangelsk, , Russia
Countries
Review the countries where the study has at least one active or historical site.
References
Explore related publications, articles, or registry entries linked to this study.
Smetkin AA, Kirov MY, Kuzkov VV, Lenkin AI, Eremeev AV, Slastilin VY, Borodin VV, Bjertnaes LJ. Single transpulmonary thermodilution and continuous monitoring of central venous oxygen saturation during off-pump coronary surgery. Acta Anaesthesiol Scand. 2009 Apr;53(4):505-14. doi: 10.1111/j.1399-6576.2008.01855.x. Epub 2009 Jan 15.
Kirov MY, Lenkin AI, Kuzkov VV, Suborov EV, Slastilin VY, Borodin VV, Chernov II, Shonbin AN, Bjertnaes LJ. Single transpulmonary thermodilution in off-pump coronary artery bypass grafting: haemodynamic changes and effects of different anaesthetic techniques. Acta Anaesthesiol Scand. 2007 Apr;51(4):426-33. doi: 10.1111/j.1399-6576.2006.01247.x.
Smetkin AA, Hussain A, Fot EV, Zakharov VI, Izotova NN, Yudina AS, Dityateva ZA, Gromova YV, Kuzkov VV, Bjertnaes LJ, Kirov MY. Estimated continuous cardiac output based on pulse wave transit time in off-pump coronary artery bypass grafting: a comparison with transpulmonary thermodilution. J Clin Monit Comput. 2017 Apr;31(2):361-370. doi: 10.1007/s10877-016-9853-5. Epub 2016 Mar 7.
Other Identifiers
Review additional registry numbers or institutional identifiers associated with this trial.
2021
Identifier Type: -
Identifier Source: org_study_id
More Related Trials
Additional clinical trials that may be relevant based on similarity analysis.