Acute Hemodynamic Effects of Pacing the His Bundle in Heart Failure

NCT ID: NCT04701112

Last Updated: 2025-02-28

Study Results

Results pending

The study team has not published outcome measurements, participant flow, or safety data for this trial yet. Check back later for updates.

Basic Information

Get a concise snapshot of the trial, including recruitment status, study phase, enrollment targets, and key timeline milestones.

Recruitment Status

TERMINATED

Clinical Phase

NA

Total Enrollment

2 participants

Study Classification

INTERVENTIONAL

Study Start Date

2021-09-01

Study Completion Date

2025-02-27

Brief Summary

Review the sponsor-provided synopsis that highlights what the study is about and why it is being conducted.

Cardiac resynchronization therapy (CRT) with biventricular pacing (BVP) is indicated for patients with low ejection fraction and persistent symptoms of heart failure despite medical therapy and a wide QRS-complex, preferably with a left bundle branch block. Unfortunately, up to 40 % receiving CRT do not respond with subjective improvement or improved left ventricular ejection fraction from the treatment.

There are few therapeutic alternatives in patients not responding to CRT with BVP, and the potential to improve cardiac function in these patients could make a large difference in terms of life quality and prognosis.

His-bundle pacing (HBP) can be a suitable alternative, but is likely not possible in all patients with failed CRT. Furthermore, upgrading to HBP does require a surgical procedure and therefore exposes the patients to risk of complications (e.g. infection of the device). Therefore, early identification of the patients who are likely to benefit from an upgrade to HBP would be beneficial.

This study aims to evaluate if patients with failed CRT treatment will benefit from hemodynamic improvement if they are treated with temporary HBP, without opening the device-pocket, and exposing the existing pacemaker-device to a risk of infection. A temporary pacemaker lead and pacing sheath will be used, and placed in the heart via a blood vessel on the right side of neck, using local anaesthesia. Acute effects on the pump function of the heart will be measured during rest and during supine bicycle test (the equivalent of moderate physical activity). Factors associated with a beneficial effect will be evaluated on a group basis.

If the individual patient experiences an improvement of cardiac function during the test, he/she will be offered an upgrade to HBP and a replacement of the existing device.

Detailed Description

Dive into the extended narrative that explains the scientific background, objectives, and procedures in greater depth.

Primary hypothesis:

His-bundle pacing will lead to a better stroke volume at rest compared to biventricular pacing.

Primary outcome measure:

Stroke-volume (ml) at rest assessed by invasive hemodynamic measurements with the thermodilution method using a Swan-Ganz catheter.

Recruitment:

Patients will be recruited from the dedicated CRT outpatient clinic at Skane University Hospital. This outpatient clinic evaluates all CRT recipients at 6 months after device implant. If the patient is then a "non-responder" by subjective and objective measures, it is unlikely that there will be any further benefit from the CRT device. Those patients fulfilling the inclusion criteria but not the exclusion criteria will therefore be invited to participate in the study. Written information will be provided to all patients prior to informed consent is signed.

Procedure:

All patients will undergo a temporary His-bundle stimulation and hemodynamic evaluation. The procedure takes place at the dedicated laboratory for advanced hemodynamic evaluation at Skåne University Hospital in Lund. The first option for vascular access is the right external jugular vein. Under sterile conditions, ultrasound guided venous puncture will be performed, using standard Seldinger technique. A 7F catheter (Medtronic C315) will then be placed over a long guidewire, and used to direct a dedicated pacemaker lead (Medtronic Select Secure 3830) to the His bundle. In case of technical difficulties, a steerable 9F catheter will be used instead (Medtronic C304 deflectable). If HBP is not possible using jugular access, an alternate access via the right femoral vein may be used instead. If the femoral vein is used, only resting measurements will be performed, since it is not possible to thread on the supine bike with a catheter in situ via the femoral vein. In parallel, in a short 8F introducer, a 7F multilumen Swan Ganz catheter will be placed over a long guidewire, and advanced to the left or right pulmonary artery. The catheter will then be wedged in a pulmonary segmental artery to obtain left atrial pressure curves.

The pacing lead will be connected to an electrophysiology 12-lead ECG system with capability of pacing and continuous ECG registration of external and intracardiac signals. His bundle potential will be identified probing the correct anatomical area with the electrode, and subsequently the pacing properties of the electrode will be tested. If the pacing properties result in selective (or subsidiary non-selective) his bundle capture, the electrode will be secured in place by 2-3 careful rotations of the entire electrode. The goal is to achieve a stable position with minimal risk of damaging the conduction system by trauma. Since the patients are paced using the CRT device anyway, trauma to the conduction system will not be deleterious, but it may hamper the ability to place a permanent HBP lead at a later stage, if that is indicated. When stable pacing conditions are in place, the stimulation program will be initiated. Depending on randomization results, the intrinsic CRT system or the temporary His-lead will be used for pacing. Pacing and sensing in the right atrium will be achieved using atrial electrodes on the outside of the Swan Ganz catheter.

The patients are randomized to wither Biventricular pacing first or HBP first. The pacing program involves both pacing at rest and pacing during sub maximal exercise test (supine bicycle test). Each pacing step is sustained at steady state for at least 2 minutes prior to measurement of intracardiac pressures, cardiac output and stroke volume calculations. After the pacing protocol is finished, the catheters are withdrawn and the site of venopuncture is manually compressed during 5 minutes. The patients are then observed during 2 hours, before discharge and completion of the study.

A hemodynamic optimization will be performed regarding device settings for all patients. Patients who have a positive hemodynamic response to HBP, compared to CRT pacing, will at a follow-up stage be offered an upgrade to permanent HBP.

Conditions

See the medical conditions and disease areas that this research is targeting or investigating.

Heart Failure, Systolic Left Bundle Branch Block Wide QRS Complex

Study Design

Understand how the trial is structured, including allocation methods, masking strategies, primary purpose, and other design elements.

Allocation Method

RANDOMIZED

Intervention Model

CROSSOVER

Primary Study Purpose

DIAGNOSTIC

Blinding Strategy

DOUBLE

Participants Outcome Assessors
The patient is not aware of the pacing modality used for each measurement. The outcomes assessment will be performed blinded to pacing modality.

Study Groups

Review each arm or cohort in the study, along with the interventions and objectives associated with them.

His-bundle pacing first

AV sequential His-bundle pacing (or VVI pacing if in atrial fibrillation) via temporary right atrial and His-bundle electrodes.

Then AV sequential Biventricular pacing via the patient's already implanted CRT device.

Measurements of stroke volume, cardiac output, pressure in the right ventricle and pulmonary capillary wedge pressure, during rest and exercise. Simultaneous 12 lead ECG registration.

Group Type EXPERIMENTAL

Temporary His bundle pacing

Intervention Type DEVICE

Temporary use of a Medtronic 3830 electrode placed in the region of His bundle, in combination with a Medtronic 5392 dual chamber external pacemaker and a temporary Edwards D200F7 Swan Ganz Pacing -catheter with atrial pacing capability.

AV synchronous pacing (DDD 60/minute during rest and 120/minute during exercise, AV delay 150/180ms) will be performed using the atrial port (pacing catheter atrial electrodes) and ventricular port (His bundle electrode), or in the case of atrial fibrillation, only pacing the the His bundle in VVI mode 60/minute during rest and 120/minute during exercise.

The Swan-Ganz will then be used for hemodynamic measurements during pacing. A Cardiotek ECG system will be used for simultaneous 12 lead ECG registration.

Biventricular pacing first

AV sequential biventricular pacing (or VVI pacing if in atrial fibrillation) via the patient's already implanted CRT device. Then AV sequential or VVI His-bundle pacing via temporary right atrial and His-bundle electrodes.

Measurements of stroke volume, cardiac output, pressure in the right ventricle and pulmonary capillary wedge pressure, during rest and exercise. Simultaneous 12 lead ECG registration.

Group Type ACTIVE_COMPARATOR

Temporary His bundle pacing

Intervention Type DEVICE

Temporary use of a Medtronic 3830 electrode placed in the region of His bundle, in combination with a Medtronic 5392 dual chamber external pacemaker and a temporary Edwards D200F7 Swan Ganz Pacing -catheter with atrial pacing capability.

AV synchronous pacing (DDD 60/minute during rest and 120/minute during exercise, AV delay 150/180ms) will be performed using the atrial port (pacing catheter atrial electrodes) and ventricular port (His bundle electrode), or in the case of atrial fibrillation, only pacing the the His bundle in VVI mode 60/minute during rest and 120/minute during exercise.

The Swan-Ganz will then be used for hemodynamic measurements during pacing. A Cardiotek ECG system will be used for simultaneous 12 lead ECG registration.

Interventions

Learn about the drugs, procedures, or behavioral strategies being tested and how they are applied within this trial.

Temporary His bundle pacing

Temporary use of a Medtronic 3830 electrode placed in the region of His bundle, in combination with a Medtronic 5392 dual chamber external pacemaker and a temporary Edwards D200F7 Swan Ganz Pacing -catheter with atrial pacing capability.

AV synchronous pacing (DDD 60/minute during rest and 120/minute during exercise, AV delay 150/180ms) will be performed using the atrial port (pacing catheter atrial electrodes) and ventricular port (His bundle electrode), or in the case of atrial fibrillation, only pacing the the His bundle in VVI mode 60/minute during rest and 120/minute during exercise.

The Swan-Ganz will then be used for hemodynamic measurements during pacing. A Cardiotek ECG system will be used for simultaneous 12 lead ECG registration.

Intervention Type DEVICE

Eligibility Criteria

Check the participation requirements, including inclusion and exclusion rules, age limits, and whether healthy volunteers are accepted.

Inclusion Criteria

* Age \>18 years
* Native QRS-duration \>130 ms and a left bundle branch block or previous His-ablation
* Heart failure in New York Heart Association functional class II-IV
* Echocardiographic non-responder to ongoing CRT defined as \<15% reduction in LVESV compared to pre-CRT examination
* Clinical non-responder to ongoing CRT, defined as lack of subjective improvement after CRT
* Signed informed consent

Exclusion Criteria

* Known access site problems in vena jugularis interna dx or sin
* Not able to perform supine cycling
* Presence of severe tricuspid regurgitation
Minimum Eligible Age

18 Years

Maximum Eligible Age

99 Years

Eligible Sex

ALL

Accepts Healthy Volunteers

No

Sponsors

Meet the organizations funding or collaborating on the study and learn about their roles.

Region Skane

OTHER

Sponsor Role lead

Responsible Party

Identify the individual or organization who holds primary responsibility for the study information submitted to regulators.

Responsibility Role SPONSOR

Principal Investigators

Learn about the lead researchers overseeing the trial and their institutional affiliations.

Oscar Braun, MD PhD

Role: PRINCIPAL_INVESTIGATOR

Region Skane, Lund University

Rasmus Borgquist, MD PhD

Role: PRINCIPAL_INVESTIGATOR

Region Skane, Lund University

Locations

Explore where the study is taking place and check the recruitment status at each participating site.

Skane University Hospital

Lund, , Sweden

Site Status

Countries

Review the countries where the study has at least one active or historical site.

Sweden

Other Identifiers

Review additional registry numbers or institutional identifiers associated with this trial.

Hepa-His trial

Identifier Type: -

Identifier Source: org_study_id

More Related Trials

Additional clinical trials that may be relevant based on similarity analysis.