The Left Bundle Cardiac Resynchronization Therapy Trial

NCT ID: NCT05434962

Last Updated: 2025-07-17

Study Results

Results pending

The study team has not published outcome measurements, participant flow, or safety data for this trial yet. Check back later for updates.

Basic Information

Get a concise snapshot of the trial, including recruitment status, study phase, enrollment targets, and key timeline milestones.

Recruitment Status

ACTIVE_NOT_RECRUITING

Clinical Phase

NA

Total Enrollment

176 participants

Study Classification

INTERVENTIONAL

Study Start Date

2022-06-27

Study Completion Date

2025-08-31

Brief Summary

Review the sponsor-provided synopsis that highlights what the study is about and why it is being conducted.

Cardiac resynchronization therapy (CRT) via biventricular (BiV) pacing significantly reduces morbidity and mortality in patients with left bundle branch block (LBBB), impaired LV function and heart failure in spite of optimal medical treatment. CRT positive effects are based on the existence of an electromechanical dyssynchrony induced by the abnormal activation sequence associated with the presence of a left bundle branch block (LBBB), which is thought to be responsible for a negative LV remodeling leading to LVEF impairment and heart failure progression. However, one third of patients undergoing CRT are considered non responders due to different reasons. Recently, left bundle branch area pacing (LBBAP) has emerged as a novel physiological pacing modality aiming for conduction system recruitment in patients with normal or impaired atrioventricular conduction, including patients with LBBB. LBBAP achieves LBBB correction in up to 85% of the cases and thus could be a promising pacing modality for CRT candidates.

Detailed Description

Dive into the extended narrative that explains the scientific background, objectives, and procedures in greater depth.

Medical device: Only CE-marked CRT-P or CRT-D Medtronic devices locally approved and commercially available (Medtronic 3830 Pacing Lead) shall be used in this protocol.

Indication: Pacing and sensing in the right atrium or ventricle. It is also designed for pacing and sensing in the bundle as an alternative to pacing in the right ventricle in a single or dual chamber pacing system.

Intended use: Patients with an indication for cardiac resynchronization therapy.

Duration of the study: Approximate inclusion period of 18 months

Follow-up: Patients will be followed for 12 months ± 4 weeks after implant

Planned study period: The study is planned to start in Q1 2022

No. of sites: Approximately 11 sites in Spain.

No. of subjects: 176 patients will be enrolled in the study

Study type: Post-market study

Study rationale: Previous studies show 85% implantation success, significant reduction in QRS duration, and significant improvement in NYHA functional class, LVEF, and LV end-diastolic diameter. Left bundle branch pacing could be an alternative to conventional biventricular pacing.

Study design: Multicenter, prospective, randomized, non-inferiority, open.

Objectives of the study:

* Primary objective: The primary objective of the study is to demonstrate that LBBAP is associated with a non-inferior percentage of CRT responders at 6 months follow-up than conventional BiV pacing using a conventional CS lead in patients with CRT indications according to current guidelines. Positive CRT response will be defined either by an improved Clinical Composite Score or ≥15% reduction in left ventricular end-systolic volume at 6 months follow-up
* Secondary objectives: To evaluate reverse ventricular remodeling response and dyssynchrony parameters based on echocardiographic data at 6 and 12 months follow-up. To asess clinical outcome using the Clinical Composite Score, 6 minute walking test, quality of life measurements (EuroQuol EQ 5-D) at 6 and 12 months follow-up. To evaluate HF related hospitalizations at 6 and 12 months follow-up. To evaluate mortality (global and cardiovascular) and need for cardiac transplantation at 6 and 12 month follow-up. To evaluate incidence of ventricular arrhythmias at 6 and 12 month follow-up. To evaluate differences in CRT response depending on the final LBBAP modality (LBBP vs deep septal pacing). To evaluate device related complications at 6 and 12 month follow-up.

Primary Outcome Measures: Improved Clinical Composite Score or ≥15% reduction in left ventricular end-systolic volume at 6 months follow-up.

Participating sites:

* Hospital Universitario y Politécnico La Fe, Valencia
* Hospital Clinic de Barcelona
* Hospital Virgen de las Nieves, Granada
* Hospital Virgen de la Arrixaca, Murcia
* Hospital Puerta de Hierro, Madrid
* Hospital General de Alicante
* Hospital Bellvitge, Barcelona
* Hospital 12 de Octubre, Madrid
* Hospital Universitario Lozano Blesa, Zaragoza
* Hospital Juan Ramón Jiménez, Huelva
* Hospital Universitario San Cecilio, Granada

Study population: Subjects 18 years of age or older will be included in the study. Both sexes are eligible to participate. Subjects must present a left bundle branch block (according to Strauss criteria) with indication of CRT class I or IIa according to clinical practice guidelines. A selection of the subjects will be made before inclusion following the selection clinical investigation plan. After confirming that the subject meets the inclusion criteria and does not meet the exclusion criteria, they will be included in the clinical study.

Study population criteria:

* Inclusion criteria: age \> 18 years; Class I or IIa indication for CRT according to current ESC or ACC/AHA/HRS guidelines; left bundle branch block according to Strauss criteria; Signed and dated informed consent.
* Exclusion criteria: Pregnant woman; Permanent or long-lasting atrial fibrillation; Previous CRT device; Previous PM/ICD with ventricular pacing \> 10%; Conventional pacemaker indication; Nonspecific IVCD (intraventricular conduction delay); Unstable angina, acute Myocardial Infarction (MI), Coronary Artery Bypass Graft (CABG), Percutaneous Coronary Angioplasty (PCI), valve repair or replacement within 90 days prior enrollment; Indication for valve repair or replacement; Already included in another clinical study that could confoud the results of the present study; Life expectancy \< 12 months.

Device Implantation Procedure: CRT obtained by biventricular pacing vs. CRT obtained by stimulating the left branch area.

Follow-up: Follow-up should be carried out with pre-established periodic clinical appointments 3, 6, and 12 months after hospital discharge. In the follow-up, routine examinations such as vital signs, electrocardiogram and echocardiogram (6 and 12 months) are recorded to check the evaluation of the reverse ventricular remodeling response and asynchrony parameters based on echocardiographic data.

Statistical considerations: Once patients have signed the informed consent at baseline visit, patients will be considered as "Enrolled population" in the statistical analysis. The sample size is based on the primary endpoint: Improved Clinical Composite Score or ≥15% reduction in left ventricular end-systolic volume at 6 months follow-up, showing that LBBAP is non-inferior to BiV-CRT. Accounting for a global attrition rate of 10% and considering the block size for randomization, 176 patients shall be enrolled.

Conditions

See the medical conditions and disease areas that this research is targeting or investigating.

Left Bundle-Branch Block Heart Failure Impaired Left Ventricular Function

Study Design

Understand how the trial is structured, including allocation methods, masking strategies, primary purpose, and other design elements.

Allocation Method

RANDOMIZED

Intervention Model

PARALLEL

Primary Study Purpose

TREATMENT

Blinding Strategy

NONE

Study Groups

Review each arm or cohort in the study, along with the interventions and objectives associated with them.

Cardiac resynchronization therapy (CRT) obtained by stimulating the left branch area

The CRT-P/CRT-D device and leads should be implanted according to the physician's standard practice. Only locally approved Medtronic CRT-P/CRT-D generators will be used during the study. It is strongly encouraged the designation of a single and experienced implanting physician at each center for the LBBAP implant procedures.

During the implant procedure lead impedances, pacing and sensing parameters will be measured using a pacing system analyzer (PSA).

For LBBAP, the Medtronic 3830 lead will be used. Acceptable LBBAP threshold should be \<2,5V@0,5ms.

Group Type EXPERIMENTAL

Cardiac resynchronization therapy

Intervention Type DEVICE

Standard BiV-CRT The CRT-P/CRT-D device and leads should be implanted according to the physician's manual provided with the devices. Only locally approved Medtronic CRT-P/CRT-D generators will be used during the study. The LV lead should be implanted at a lateral or posterolateral CS branch in a basal or mid ventricular position confirmed by ortogonal fluoroscopic views (RAO and LAO 40º). Acceptable LV pacing threshold should be \<3V@0,5ms and phrenic nerve stimulation (PNS) margin should be \>1V with respect to the pacing threshold.

LBBAP-CRT The CRT-P/CRT-D device and leads should be implanted according to the physician's standard practice. Only locally approved Medtronic CRT-P/CRT-D generators will be used during the study. During the implant procedure lead impedances, pacing and sensing parameters will be measured using a pacing system analyzer (PSA). For LBBAP, the Medtronic 3830 lead will be used. Acceptable LBBAP threshold should be \<2,5V@0,5ms

Cardiac resynchronization therapy (CRT) obtained by biventricular pacing

The CRT-P/CRT-D device and leads should be implanted according to the physician's manual provided with the devices. Only locally approved Medtronic CRT-P/CRT-D generators will be used during the study.

Investigators may use any market approved right atrial (RA) pace/sense lead, right ventricular (RV) pacing/defibrillator lead with pace/sense capabilities and any market approved unipolar/bipolar/quadripolar LV pacing lead.

During the implant procedure lead impedances, pacing and sensing parameters will be measured using a pacing system analyzer (PSA).

The LV lead should be implanted at a lateral or posterolateral CS branch in a basal or mid ventricular position confirmed by ortogonal fluoroscopic views (RAO and LAO 40º).

Acceptable LV pacing threshold should be \<3V@0,5ms and phrenic nerve stimulation (PNS) margin should be \>1V with respect to the pacing threshold

Group Type ACTIVE_COMPARATOR

Cardiac resynchronization therapy

Intervention Type DEVICE

Standard BiV-CRT The CRT-P/CRT-D device and leads should be implanted according to the physician's manual provided with the devices. Only locally approved Medtronic CRT-P/CRT-D generators will be used during the study. The LV lead should be implanted at a lateral or posterolateral CS branch in a basal or mid ventricular position confirmed by ortogonal fluoroscopic views (RAO and LAO 40º). Acceptable LV pacing threshold should be \<3V@0,5ms and phrenic nerve stimulation (PNS) margin should be \>1V with respect to the pacing threshold.

LBBAP-CRT The CRT-P/CRT-D device and leads should be implanted according to the physician's standard practice. Only locally approved Medtronic CRT-P/CRT-D generators will be used during the study. During the implant procedure lead impedances, pacing and sensing parameters will be measured using a pacing system analyzer (PSA). For LBBAP, the Medtronic 3830 lead will be used. Acceptable LBBAP threshold should be \<2,5V@0,5ms

Interventions

Learn about the drugs, procedures, or behavioral strategies being tested and how they are applied within this trial.

Cardiac resynchronization therapy

Standard BiV-CRT The CRT-P/CRT-D device and leads should be implanted according to the physician's manual provided with the devices. Only locally approved Medtronic CRT-P/CRT-D generators will be used during the study. The LV lead should be implanted at a lateral or posterolateral CS branch in a basal or mid ventricular position confirmed by ortogonal fluoroscopic views (RAO and LAO 40º). Acceptable LV pacing threshold should be \<3V@0,5ms and phrenic nerve stimulation (PNS) margin should be \>1V with respect to the pacing threshold.

LBBAP-CRT The CRT-P/CRT-D device and leads should be implanted according to the physician's standard practice. Only locally approved Medtronic CRT-P/CRT-D generators will be used during the study. During the implant procedure lead impedances, pacing and sensing parameters will be measured using a pacing system analyzer (PSA). For LBBAP, the Medtronic 3830 lead will be used. Acceptable LBBAP threshold should be \<2,5V@0,5ms

Intervention Type DEVICE

Eligibility Criteria

Check the participation requirements, including inclusion and exclusion rules, age limits, and whether healthy volunteers are accepted.

Inclusion Criteria

* age \> 18 years
* Class I or IIa indication for CRT according to current ESC or ACC/AHA/HRS guidelines
* left bundle branch block according to Strauss criteria
* Signed and dated informed consent

Exclusion Criteria

* Pregnant woman
* Permanent or long-lasting atrial fibrillation
* Previous CRT device
* Previous PM/ICD with ventricular pacing \> 10%
* Conventional pacemaker indication
* Nonspecific IVCD (intraventricular conduction delay)
* Unstable angina, acute Myocardial Infarction (MI), Coronary Artery Bypass Graft (CABG), Percutaneous Coronary Angioplasty (PCI), valve repair or replacement within 90 days prior enrollment
* Indication for valve repair or replacement
* Already included in another clinical study that could confoud the results of the present study
* Life expectancy \< 12 months
Minimum Eligible Age

18 Years

Eligible Sex

ALL

Accepts Healthy Volunteers

No

Sponsors

Meet the organizations funding or collaborating on the study and learn about their roles.

Spanish Society of Cardiology

OTHER

Sponsor Role collaborator

Óscar Cano Pérez

OTHER

Sponsor Role lead

Responsible Party

Identify the individual or organization who holds primary responsibility for the study information submitted to regulators.

Óscar Cano Pérez

Cardiologist

Responsibility Role SPONSOR_INVESTIGATOR

Locations

Explore where the study is taking place and check the recruitment status at each participating site.

Hospital General Universitario de Alicante Doctor Balmis

Alicante, Alicante, Spain

Site Status

Hospital Universitario de Bellvitge

L'Hospitalet de Llobregat, Barcelona, Spain

Site Status

Hospital Universitario Virgen de las Nieves

Granada, Granada, Spain

Site Status

Hospital Universitario San Cecilio

Granada, Granada, Spain

Site Status

Hospital Universitario Juan Ramón Jiménez

Huelva, Huelva, Spain

Site Status

Hospital 12 Octubre

Madrid, Madrid, Spain

Site Status

Hospital Universitario Puerta De Hierro

Majadahonda, Madrid, Spain

Site Status

Hospital Universitario Virgen de la Arrixaca

Murcia, Murcia, Spain

Site Status

Hospital Universitari i Politècnic La Fe

Valencia, Valencia, Spain

Site Status

Hospital Clínico Universitario Lozano Blesa

Zaragoza, Zaragoza, Spain

Site Status

Countries

Review the countries where the study has at least one active or historical site.

Spain

Other Identifiers

Review additional registry numbers or institutional identifiers associated with this trial.

LB-CRT-001

Identifier Type: -

Identifier Source: org_study_id

More Related Trials

Additional clinical trials that may be relevant based on similarity analysis.

AI-Guided Left Bundle Branch Area Pacing
NCT07206602 NOT_YET_RECRUITING NA