Trajectory Changes of Coronary Sinus Lead Tip and Cardiac Resynchronization Therapy Outcome
NCT ID: NCT02340546
Last Updated: 2020-03-23
Study Results
The study team has not published outcome measurements, participant flow, or safety data for this trial yet. Check back later for updates.
Basic Information
Get a concise snapshot of the trial, including recruitment status, study phase, enrollment targets, and key timeline milestones.
COMPLETED
119 participants
OBSERVATIONAL
2015-01-31
2019-12-31
Brief Summary
Review the sponsor-provided synopsis that highlights what the study is about and why it is being conducted.
Related Clinical Trials
Explore similar clinical trials based on study characteristics and research focus.
Randomized Comparison of Endocardial Versus Epicardial - From the Coronary Sinus - Left Ventricular Pacing for Resynchronization in Heart Failure.
NCT01260402
His Bundle Pacing Versus Coronary Sinus Pacing for Cardiac Resynchronization Therapy
NCT02700425
Cardiac Resynchronization Therapy in Congenital Heart Defects
NCT00450684
Effects of Multipoint Pacing CRT-D on Neurohormonal Activation.
NCT02139891
Echo Assessment of Intraventricular Dyssynchrony
NCT00646243
Detailed Description
Dive into the extended narrative that explains the scientific background, objectives, and procedures in greater depth.
Since LV pacing is currently delivered on the epicardium by a lead inserted in coronary sinus (CS) branches, the interface between the point of pacing delivery on LV surface and the underlying LV wall, and overall lead movements inside coronary sinus might describe some underlying myocardial mechanics. By means of a recently published fluoroscopy-based method, the trajectory of the electrode tip inserted in CS branches can be reconstructed in three-dimensions (3D) throughout the cardiac cycle. A preliminary clinical pilot study (Heart Rhythm 2013;10:1360) demonstrated that biventricular pacing acutely induced changes in trajectory geometry, which were correlated to the echocardiographic volumetric response to CRT at six-month post-implant follow-up. In responders only, biventricular pace abruptly determined a more circular shape. Such results were "hypothesis-generating" and are to be yet tested on a larger scale.
The study analyzes the predictive power of the changes in pacing cathode trajectory metrics occurring at the start of biventricular pacing with respect to both:
1. the volumetric response to CRT, measured at six-month follow-up by a unique criterion;
2. the clinical response to CRT, described at six-month follow-up by three clinical indices.
Secondarily, this study evaluates whether trajectory variations would be able to acutely guide the selection of the definitive LV pacing configuration in the subset of implants of a CS quadripolar lead.
The trajectory geometry metrics to analyze are:
* trajectory length;
* area of the surface encompassed by the trajectory in the 3D space;
* trajectory mean curvature;
* the three singular values indicating to what extent the trajectory is distributed along each of its three principal directions (eigenvectors);
* ratio between the two main singular values, indicating to what extent the trajectory is distributed along only one (principal) direction;
* trajectory eccentricity;
* distance between the trajectory barycenter.
Operatively:
* patients submitted to implant of a CRT device (pacemaker or implantable cardioverter defibrillator) according to current indications are evaluated;
* all market-released CRT devices can be implanted; the choice of CS lead, implantation technique, leads placement is left to each investigator decision;
* during implant procedure, the devices are programmed in sense-only mode; if upgrades, the pre-existing pacing programming is kept unmodified until the start of biventricular stimulation;
* short fluoroscopy recordings of lead movements inside CS branching are taken in three radiological projections (posteroanterior, 30° right and left anterior oblique), both just before and immediately after the beginning of biventricular pacing at prefixed settings, which are: lower rate at 60-70 beats per min; atrioventricular (AV) delay at 120 ms and interventricular (VV) delay at 0 ms;
* in the subset of implants of a quadripolar lead, other two fluoroscopic recordings are acutely acquired during a short period of pacing from each of two other cathodes, which are predefined as being at 20-35 mm and 40-50 mm from lead tip;
* 3D trajectories are reconstructed for the lead tip (the distal pole), and, in quadripolar lead implants, also for other two pacing cathodes, both before and acutely at biventricular pacing start;
* after acquisition, at any time pacing settings can be optimized and modified at investigators choice;
* if a quadripolar CS lead is used, the pacing configuration at discharge is preferably chosen as that associated with the largest change of cathode trajectory towards a more circular shape at biventricular pace start;
* CRT device checking is scheduled at 6-month follow-up; other checks are left to the discretion of each center; a visit is advised at 30-60 days after discharge;
* all centers arrange for the two index echocardiographic evaluations to be performed on schedule by an expert operator, who has to be blinded about any trajectory results, and according to recommendations of the American Society of Echocardiography. All examinations are recorded on external support (analogic or digital) and handed to the internal Echocardiography Core-Lab, which is identified among participating institutions. The Echo Core-Lab operator(s) is not directly involved in the study and is kept unaware of all trajectory results up to the end of the study;
* the fluoroscopic recordings are stored on a CD and analyzed off-line by the Engineering Core Lab, using the method previously published.
The following variables are collected at baseline
\- age, gender, height and weight; presence of diabetes, hypertension, chronic obstructive bronchopneumopathy, previous stroke, previous myocardial infarction; moderate to severe valvular heart disease; any previous myocardial revascularization; previous heart surgery; chronic renal failure,defined by glomerular filtration rate (eGFR) \<60 mL/min/1.73 square metre; current value of eGFR (mL/min/1.73 square metre); current medical treatment with beta-blockers, diuretics, ACE inhibitors, angiotensin II antagonists, aldosterone antagonists, antiarrhythmic, oral anticoagulants, anti-platelets.
The following variables are collected both at peri-implant and at six-month follow-up:
1. Clinical : New York Heart Association (NYHA) functional class (I to IV); distance covered at the six minutes walking test (metres); total hospital stay due to heart failure during 6 months before and 6 months after CRT implant (number of days).
2. Echocardiographic: LV ejection fraction (%); LV end-diastolic and end-systolic volumes (ml); presence and degree of any valvular regurgitation (from 1+ to 4+) and valvular stenosis; Doppler-derived peak pressure in pulmonary artery (mmHg); pulsed doppler pattern of transmitral flow (three types) and associated E/A ratio (abs), E wave duration (msec), A wave duration (msec), E+A waves total duration (msec).
3. Electrocardiographic: P wave, AV interval and QRS complex durations (msec); QRS axis (degrees); QRS morphology (four types: spontaneous typical or atypical left bundle branch block; RV pace-induced conduction delay; non-specific intraventricular delay).
4. Device-related: endocavitary measurements of atrial, RV and CS leads functioning (pace and sense thresholds, impedance); all programmed values of sensing and pacing; programmed AV and VV intervals; total percent time of LV pacing; burden and types of any supraventricular and ventricular tachyarrhythmias.
To define the sample size, the statistical power analysis is applied with a level of power equal to 80%, using as sample distributions the populations in the pilot study (p\<0.05) and considering a drop-out rate of 20%.
Descriptive statistics are used to present and summarize the data collected in the study. For discrete variables, frequency distribution and cross tabulations are to be presented. For continuous variables, the means, standard deviations, or median and 25° and 75° percentile and ranges are used to represent data.
According to the type of variable, computed trajectory parameters are to be compared by using χ2 method, with the Fisher exact test or the nonparametric Mann-Whitney U test for non-normal distribution (p\<0.05). Differences in means or in proportions are to be calculated, together with their 95% confidence intervals.
Variations in trajectory metrics from before to after pacing start are computed and correlated with variations between pre-implant and six-month post-implant assessments in both echocardiographic measures of left ventricular remodeling and function and clinical and electrocardiographic variables.
Study data are managed as follows:
* each patient is given a code to guarantee anonymity, used to identify both data on paper and imaging recordings (fluoroscopic and echocardiographic). Recordings are supplied to the Core-Labs (Bioengineering and Echocardiography) on digital support. Results from imaging recordings analyses are sent to the Principal Investigator and to the Steering Committee (composed by the Principal Investigator, the Study Directors and the Sites Principal Investigators). The original recordings are kept in each center's archives;
* all patient's data are collected on paper forms. Each center's investigator is responsible for data collection and safekeeping, and guarantees for data reliability and correctness;
* each center's data are the property of the same center; each investigator has free access to its own data and can divulge them, but without associating them with the study TRAJECTORIES. The Steering Committee alone is responsible for the whole, appropriately codified database, and can freely accede to it. Each investigator will be allowed to propose ancillary substudies/subanalyses which are to use data already provided in accordance with the protocol. Proposals have to be submitted to and approved by the Steering Committee;
* the study does not interfere with any aspect of current good clinical practice and legal requirements, and all prevailing rules will be followed.The study conforms to the guiding principles of the Declaration of Helsinki, to the current laws and to the Institutional Ethics Committee rules.The protocol has been first approved by the Area Vasta Romagna Ethics Committee, and then is submitted to other competent Ethics Committees for all participating centers;
* adverse events and adverse device effects, defined according to current standards, will be dealt with and reported to regulatory agencies and to manufacturers by each center in accordance with present regulations. The investigator ensures that, if applicable, adverse events are reported to their Ethical Committee, and/or to any Health Authorities according to national laws.
This study is conducted in accordance with Good Clinical Practice (GCP), International Standards Organization (ISO) 14155 and Declaration of Helsinki guidelines.The investigators are responsible for conducting the study in accordance with the study plan, the signed agreements, applicable laws and regulations, and any conditions of approval imposed by the reviewing Ethics Committee.
Patient informed consent is mandatory and required for all patients prior to their inclusion in the study. The process of obtaining informed consent complies with the Declaration of Helsinki and applicable national regulations, and uses language that is understandable to the patient. The informed consent form is constructed in accordance with rules given by Area Vasta Romagna Ethic Committee.The form is signed in double original, and one is given to patient, the second original kept in patients' file. The informed consent covers the use of personal information in an anonymous form and only for scientific purposes, and the acceptation of fluoroscopy as a means of clinical investigation. Patients can modify their decision at any moment, and nothing will be changed in their care and clinical programs.
Conditions
See the medical conditions and disease areas that this research is targeting or investigating.
Study Design
Understand how the trial is structured, including allocation methods, masking strategies, primary purpose, and other design elements.
COHORT
PROSPECTIVE
Interventions
Learn about the drugs, procedures, or behavioral strategies being tested and how they are applied within this trial.
cardiac resynchronization therapy
cardiac resynchronization by means of biventricular pacing via left ventricular pace from coronary sinus veins combined with conventional any-site right ventricular pace
Eligibility Criteria
Check the participation requirements, including inclusion and exclusion rules, age limits, and whether healthy volunteers are accepted.
Inclusion Criteria
2. chronic systolic heart failure recognized for more than 6 months, with left ventricular systolic disfunction (ejection fraction ≤ 35%) and NYHA II-III or ambulatory IV class symptoms despite optimal medical treatment;
3. QRS complex on the surface electrocardiogram with left bundle branch block morphology and duration ≥ 120 ms, either typical or atypical or induced by right ventricular pacing due to stable chronic advanced atrio-ventricular block; QRS with with non-specific intraventricular delay lasting ≥ 150 ms;
4. a regular ventricular rhythm, either with spontaneous atrio-ventricular conduction or with ventricular pacing via a chronically implanted antibradycardia device; with sinus rhythm unless atrial fibrillation is permanent and associated with a permanent high-degree atrio-ventricular block with a spontaneous ventricular rate constantly ≤ 45 beats per minute;
5. no concomitant bradyarrhythmias being per se an indication for new implant ventricular pacing; upgrade to cardiac resynchronization therapy only if a previous pacemaker or implantable cardioverter-defibrillator was implanted more than 6 months previously;
6. a stable clinical and hemodynamic condition during cardiac resynchronization therapy device implant, and at the acquisition time heat rate between 50 and 100 beats per minute and respiratory rate ≤ 25 breaths per minute;
Exclusion Criteria
2. occurrence of myocardial infarction, valve repair or surgery, or coronary revascularization in the past 6 months;
3. any arrhythmia at the acquisition time which frequently alters the regularity of a minimum of five consecutive heart beats;
4. participation in any other competing clinical study, with the exception of registries ruled by National Health Service Authorities or Agencies, and observational studies/registries which are not conflicting and do not interfere with any of the following aspects:
1. the program of procedures/assessments requested by the present study;
2. the outcome of the present study due to the requirement of medical treatments or interventions which are able to modify the clinical conditions of patients.
18 Years
ALL
No
Sponsors
Meet the organizations funding or collaborating on the study and learn about their roles.
University of Bologna
OTHER
Corrado Tomasi
OTHER
Responsible Party
Identify the individual or organization who holds primary responsibility for the study information submitted to regulators.
Corrado Tomasi
Cardiologist, Chief Electrophisiologist of the Cardiovascular Department
Principal Investigators
Learn about the lead researchers overseeing the trial and their institutional affiliations.
Corrado Tomasi, M D
Role: PRINCIPAL_INVESTIGATOR
Ospedale Santa Maria delle Croci, Ravenna, Italy
Stefano Severi, Engeneer
Role: STUDY_DIRECTOR
University of Bologna
Cristiana Corsi, Engeneer
Role: STUDY_DIRECTOR
Engeneering Department , University of Bologna, Italy
Locations
Explore where the study is taking place and check the recruitment status at each participating site.
Poiliclinico Sant'Orsola-Malpighi
Bologna, BO, Italy
Ospedale Maurizio Bufalini
Cesena, FC, Italy
Ospedale Santa Maria delle Croci
Ravenna, RA, Italy
Ospedale Mater Salutis
Legnago, Verona, Italy
Ospedale Classificato Equiparato Sacro Cuore - Don Calabria -
Negrar, VR, Italy
Ospedale S Maria della Misericordia - AUSL 18 del Veneto
Rovigo, , Italy
Ospedale San Bortolo
Vicenza, , Italy
Countries
Review the countries where the study has at least one active or historical site.
Other Identifiers
Review additional registry numbers or institutional identifiers associated with this trial.
1368/2014
Identifier Type: -
Identifier Source: org_study_id
More Related Trials
Additional clinical trials that may be relevant based on similarity analysis.