Reliability of a Proprioception Test in Swimmers

NCT ID: NCT04697108

Last Updated: 2021-01-06

Study Results

Results pending

The study team has not published outcome measurements, participant flow, or safety data for this trial yet. Check back later for updates.

Basic Information

Get a concise snapshot of the trial, including recruitment status, study phase, enrollment targets, and key timeline milestones.

Recruitment Status

COMPLETED

Clinical Phase

NA

Total Enrollment

48 participants

Study Classification

INTERVENTIONAL

Study Start Date

2020-02-03

Study Completion Date

2020-03-16

Brief Summary

Review the sponsor-provided synopsis that highlights what the study is about and why it is being conducted.

To evaluate the intra- and inter-rater reliability of a test of active shoulder proprioception with a laser pointer in swimming athletes and to describe the profile of the proprioception measures characterizing the sample according to the specialty within the sport and the category of the athletes.

Detailed Description

Dive into the extended narrative that explains the scientific background, objectives, and procedures in greater depth.

Introduction: Obtaining the reliability of an evaluative instrument is of paramount importance for its applicability in the field of clinical physiotherapy and in the sports field, providing consistent and real measures. Shoulder proprioception assessments have started to appear on the scientific scene in recent years and several tools, methods and protocols are being studied. However, the lack of standardization of protocols and application in different populations produces inconsistencies in the findings, thus hindering the use of these models. Thus, standardizing the application of the test and investigating a population different from what appears in the scientific scenario in relation to sports, such as swimming athletes, seems to be relevant and would contribute to the use of scientific evaluative models in the clinical environment. Objectives: To evaluate the intra- and inter-rater reliability of a test of active shoulder proprioception with a laser pointer in swimming athletes and to describe the profile of the proprioception measures characterizing the sample according to the specialty within the sport and the category of the athletes. Methods: Study of intra- and inter-rater reliability of the shoulder proprioception test with a laser pointer, composed of 48 young male and female swimming athletes, aged between 12 and 20 years. It will be carried out in three stages: (1) Familiarization, (2) Test and (3) Retest, all stages will take place on the same day, and stages 2 and 3 will be performed by two different evaluators. To characterize the sample, descriptive statistics will be used by means of central tendency and variability, for all variables collected. Relative reliability will be tested by the Intraclass Correlation Coefficient (ICC), with a 95% confidence interval. The ICC will be interpreted as values \<0.5 indicate low reliability, between 0.5 and 0.75, moderate reliability, between 0.75 and 0.9, good reliability and values\> 0.90 excellent reliability. And the absolute reliability will be verified by means of the standard error of the measurement (EPM), by values of minimum detectable change (MMD), and the coefficient of variation (CV).

Conditions

See the medical conditions and disease areas that this research is targeting or investigating.

Athletes

Study Design

Understand how the trial is structured, including allocation methods, masking strategies, primary purpose, and other design elements.

Allocation Method

NA

Intervention Model

SINGLE_GROUP

Primary Study Purpose

OTHER

Blinding Strategy

NONE

Study Groups

Review each arm or cohort in the study, along with the interventions and objectives associated with them.

Proprioception Test (TRMOPL)

In the Familiarization stage (1), the TRMOPL was applied by means of a single evaluator with the aim of knowledge and understanding of the test. After five minutes, step (2) test started. In this step, the test was applied twice, by different evaluators, with an interval of five minutes between applications (inter-rater reliability). Ten minutes after the end of the tests, step (3) retest (intra-rater reliability) was started, following the same procedures as in step 2. The order of the evaluators was randomized through a draw in Excel, the order of randomization of the steps (2) and (3) was the same in order not to influence intra-rater reliability.

Group Type OTHER

Shoulder reproduction teste assisted by laser pointer

Intervention Type OTHER

In the step (1) of Familiarization in which the SRTLP was applied through a single evaluator with the aim of knowledge and understanding of the test. After five minutes, step (2) test started. In this step, the test was applied twice, by different evaluators, with an interval of five minutes between applications (inter-rater reliability). Ten minutes after the end of the tests, step (3) retest (intra-rater reliability) was started, following the same procedures as in step 2. The order of the evaluators was randomized through a draw in Excel, the order of randomization of the steps (2) and (3) was the same in order not to influence intra-rater reliability

Interventions

Learn about the drugs, procedures, or behavioral strategies being tested and how they are applied within this trial.

Shoulder reproduction teste assisted by laser pointer

In the step (1) of Familiarization in which the SRTLP was applied through a single evaluator with the aim of knowledge and understanding of the test. After five minutes, step (2) test started. In this step, the test was applied twice, by different evaluators, with an interval of five minutes between applications (inter-rater reliability). Ten minutes after the end of the tests, step (3) retest (intra-rater reliability) was started, following the same procedures as in step 2. The order of the evaluators was randomized through a draw in Excel, the order of randomization of the steps (2) and (3) was the same in order not to influence intra-rater reliability

Intervention Type OTHER

Eligibility Criteria

Check the participation requirements, including inclusion and exclusion rules, age limits, and whether healthy volunteers are accepted.

Inclusion Criteria

* Male and female swimming athletes;
* Between 12 and 26 years old;
* Train regularly and be members of swimming teams in the 4th Region of the State of São Paulo, and athletes from the São Paulo Aquatic Federation (FAP),
* Reporting the absence of anemia, inflammatory process, diabetes, cardiovascular disease, episodes of muscle - tendon or osteoarticular injury in the lower, upper and / or spine members in the last three months.

Exclusion Criteria

* Practice of sports for less than 1 year.
* Use anti-inflammatory and / or analgesic drugs for less than 24 hours before the test.
Minimum Eligible Age

12 Years

Maximum Eligible Age

20 Years

Eligible Sex

ALL

Accepts Healthy Volunteers

Yes

Sponsors

Meet the organizations funding or collaborating on the study and learn about their roles.

São Paulo State University

OTHER

Sponsor Role lead

Responsible Party

Identify the individual or organization who holds primary responsibility for the study information submitted to regulators.

Responsibility Role SPONSOR

Locations

Explore where the study is taking place and check the recruitment status at each participating site.

University of São Paulo State

Presidente Prudente, São Paulo, Brazil

Site Status

Countries

Review the countries where the study has at least one active or historical site.

Brazil

Other Identifiers

Review additional registry numbers or institutional identifiers associated with this trial.

FIS190111

Identifier Type: -

Identifier Source: org_study_id

More Related Trials

Additional clinical trials that may be relevant based on similarity analysis.

Assessment of Spinal Stability
NCT01060358 COMPLETED