Pleural Manometry for the Characterization of Spontaneous and Tension Pneumothorax
NCT ID: NCT04630301
Last Updated: 2025-10-20
Study Results
Outcome measurements, participant flow, baseline characteristics, and adverse events have been published for this study.
View full resultsBasic Information
Get a concise snapshot of the trial, including recruitment status, study phase, enrollment targets, and key timeline milestones.
COMPLETED
37 participants
OBSERVATIONAL
2021-02-17
2025-07-31
Brief Summary
Review the sponsor-provided synopsis that highlights what the study is about and why it is being conducted.
Related Clinical Trials
Explore similar clinical trials based on study characteristics and research focus.
Impact of Pleural Manometry on Chest Discomfort After Therapeutic Thoracentesis
NCT02677883
Pleurostrain: Interest of Strain Ultrasound in the Diagnosis of Pneumothorax
NCT03907150
Coronavirus Associated Pneumomediastinum and Pneumothorax
NCT04897152
Prospective Study on Clinical Outcomes of Spontaneous Pneumothorax
NCT05397717
Impact of Pleural Manometry on the Assessment and Treatment of Malignant Pleural Effusion: A Pilot Clinical Trial
NCT07120867
Detailed Description
Dive into the extended narrative that explains the scientific background, objectives, and procedures in greater depth.
The lack of prognostic indicators is not the case in pleural effusions, however. Pleural manometry has been shown to be a useful tool in the management of patients with effusions. Doelken et al. described using an overdamped water manometer or an electronic transducer connected to a thoracentesis catheter for the direct measurement of Ppl with similar accuracy. Traditionally, thoracenteses are aborted after onset of dyspnea or cough, all fluid is drained, or 1 liter of fluid has been removed. This 1 liter limit exists to avoid the feared complicated of reexpansion pulmonary edema. However, monitoring of Ppl during drainage and aborting the procedure once Ppl drops below -20 cmH2O allows for safe drainage of often larger volumes. - Furthermore, it has been demonstrated that Ppl could diagnose non-expandable lung and predict pleurodesis failure in patients with malignant effusion. We recently reported the use of a simple, in-line, digital manometer to measure Ppl in patients with pleural effusion.
Routine use of pleural manometry in the evaluation and management of pneumothorax has not yet been adopted, likely due to the historical difficulty in obtaining measurements and the uncertain clinical benefit pleural manometry provided. It has been found that Ppl in spontaneous pneumothorax was greater in patients that required prolonged drainage. These results were later supported in a study that demonstrated the practicality of measuring Ppl in pneumothorax. Ppl measurements required only up to 30 seconds by using an electronic manometer connected to an intrapleural catheter. Still to date, Ppl in TP have yet to be reported. Ultimately, measurement of Ppl in pneumothorax may help identify patients at increased risk for the need of advanced therapies such as IBV placement, pleurodesis, or VATS. Early identification of these high-risk patients will allow for these interventions to be performed earlier, thus reducing hospital length of stay, associated complications, and health-care costs.
4\. Study Procedures
1. Patients admitted to the Johns Hopkins Hospital with spontaneous, iatrogenic, or tension pneumothorax referred to the Division of Interventional Pulmonology for thoracostomy will be recruited. Using standard sterile technique, a 14fr catheter will be inserted into the pleural space. An electronic manometer (Compass, Medline Industries, Inc.) will be connected in-line to the introducer needle and Ppl will be recorded for 3-5 respiratory cycles. After measurement, the manometer will be removed and the catheter will remain in place per routine standards of practice. Outcome data of patients will be collected including duration of chest tube placement, need for pleurodesis, IBV, and referral for VATS. Patient data will be de-identified and stored on the a Johns Hopkins secured (SAFE) desktop. A separate file will also be kept on the SAFE desktop that contains participant Medical Record Numbers to allow for matching of Ppl measurements with clinical outcomes. Once outcome data is collected for a participant, the participant's identifiable information will be removed. A combined waiver of consent and oral consent process will be used. The waiver of consent will allow performance of chest tube placement and the collection of pressure measurements via the manometer without the consent of potential subjects. Subsequently, an oral consent process will be used to invite potential subjects to enroll in the study and to get consent for the use of the pressure data already collected as well as for further data collection from the patients' medical records.
2. No biospecimens will be collected.
3. Patients will be enrolled over the course of 1 year. The study will not impact length of hospitalization.
4. This is a nonblinded study.
5. Patients will continue to receive standard of care treatments. This study may delay catheter placement by mere seconds to accommodate for Ppl measurements, this delay is negligible and
6. will not impact clinical outcomes as even in the case of tension the pleural air will be evacuated via the introducer needle.
7. This study does not include a placebo group.
8. Participant removal criteria include pneumothorax in which Ppl cannot be reliably measured within 30 seconds.
9. Participants removed from the study will continue to receive standard-of-care treatment.
Conditions
See the medical conditions and disease areas that this research is targeting or investigating.
Study Design
Understand how the trial is structured, including allocation methods, masking strategies, primary purpose, and other design elements.
CASE_ONLY
PROSPECTIVE
Study Groups
Review each arm or cohort in the study, along with the interventions and objectives associated with them.
Measurement of pleural pressure
a. Patients admitted to the Johns Hopkins Hospital with spontaneous, iatrogenic, or tension pneumothorax referred to the Division of Interventional Pulmonology for thoracostomy will be recruited. Using standard sterile technique, a 14fr catheter will be inserted into the pleural space. An electronic manometer (Compass, Medline Industries, Inc.) will be connected in-line to the introducer needle and Ppl will be recorded for 3-5 respiratory cycles. After measurement, the manometer will be removed and the catheter will remain in place per routine standards of practice.
No interventions assigned to this group
Eligibility Criteria
Check the participation requirements, including inclusion and exclusion rules, age limits, and whether healthy volunteers are accepted.
Inclusion Criteria
Exclusion Criteria
18 Years
ALL
No
Sponsors
Meet the organizations funding or collaborating on the study and learn about their roles.
Medline Industries, Inc
UNKNOWN
Johns Hopkins University
OTHER
Responsible Party
Identify the individual or organization who holds primary responsibility for the study information submitted to regulators.
Principal Investigators
Learn about the lead researchers overseeing the trial and their institutional affiliations.
Jeffrey Thiboutot, MD, MHS
Role: PRINCIPAL_INVESTIGATOR
Johns Hopkins University
Locations
Explore where the study is taking place and check the recruitment status at each participating site.
Johns Hopkins Hospital
Baltimore, Maryland, United States
University of Michigan Medical School
Ann Arbor, Michigan, United States
Dartmouth Hitchcock Medical Center
Lebanon, New Hampshire, United States
Albany Medical Center
Albany, New York, United States
Countries
Review the countries where the study has at least one active or historical site.
References
Explore related publications, articles, or registry entries linked to this study.
Sahn SA, Heffner JE. Spontaneous pneumothorax. N Engl J Med. 2000 Mar 23;342(12):868-74. doi: 10.1056/NEJM200003233421207. No abstract available.
MacDuff A, Arnold A, Harvey J; BTS Pleural Disease Guideline Group. Management of spontaneous pneumothorax: British Thoracic Society Pleural Disease Guideline 2010. Thorax. 2010 Aug;65 Suppl 2:ii18-31. doi: 10.1136/thx.2010.136986. No abstract available.
Bobbio A, Dechartres A, Bouam S, Damotte D, Rabbat A, Regnard JF, Roche N, Alifano M. Epidemiology of spontaneous pneumothorax: gender-related differences. Thorax. 2015 Jul;70(7):653-8. doi: 10.1136/thoraxjnl-2014-206577. Epub 2015 Apr 27.
Brown SGA, Ball EL, Perrin K, Asha SE, Braithwaite I, Egerton-Warburton D, Jones PG, Keijzers G, Kinnear FB, Kwan BCH, Lam KV, Lee YCG, Nowitz M, Read CA, Simpson G, Smith JA, Summers QA, Weatherall M, Beasley R; PSP Investigators. Conservative versus Interventional Treatment for Spontaneous Pneumothorax. N Engl J Med. 2020 Jan 30;382(5):405-415. doi: 10.1056/NEJMoa1910775.
Doelken P, Huggins JT, Pastis NJ, Sahn SA. Pleural manometry: technique and clinical implications. Chest. 2004 Dec;126(6):1764-9. doi: 10.1378/chest.126.6.1764.
Feller-Kopman D, Berkowitz D, Boiselle P, Ernst A. Large-volume thoracentesis and the risk of reexpansion pulmonary edema. Ann Thorac Surg. 2007 Nov;84(5):1656-61. doi: 10.1016/j.athoracsur.2007.06.038.
Light RW, Jenkinson SG, Minh VD, George RB. Observations on pleural fluid pressures as fluid is withdrawn during thoracentesis. Am Rev Respir Dis. 1980 May;121(5):799-804. doi: 10.1164/arrd.1980.121.5.799.
Lan RS, Lo SK, Chuang ML, Yang CT, Tsao TC, Lee CH. Elastance of the pleural space: a predictor for the outcome of pleurodesis in patients with malignant pleural effusion. Ann Intern Med. 1997 May 15;126(10):768-74. doi: 10.7326/0003-4819-126-10-199705150-00003.
Lee HJ, Yarmus L, Kidd D, Amador RO, Akulian J, Gilbert C, Hughes A, Thompson RE, Arias S, Feller-Kopman D. Comparison of pleural pressure measuring instruments. Chest. 2014 Oct;146(4):1007-1012. doi: 10.1378/chest.13-3004.
Herrejon A, Inchaurraga I, Vivas C, Custardoy J, Marin J. Initial pleural pressure measurement in spontaneous pneumothorax. Lung. 2000;178(5):309-16. doi: 10.1007/s004080000034.
Kaneda H, Nakano T, Murakawa T. Measurement of intrapleural pressure in patients with spontaneous pneumothorax: a pilot study. BMC Pulm Med. 2019 Dec 30;19(1):267. doi: 10.1186/s12890-019-1038-9.
Latifi A, Wang D, Backer ED, Madisi N, Chopra A, Kapp CM, Wayne M, Howe J, Pai C, Yarmus L, Feller-Kopman D, Thiboutot J. Pleural Manometry in Pneumothorax: Evaluating Tension Physiology and Predicting Outcomes. Chest. 2025 Oct 10:S0012-3692(25)05492-3. doi: 10.1016/j.chest.2025.09.121. Online ahead of print.
Provided Documents
Download supplemental materials such as informed consent forms, study protocols, or participant manuals.
Document Type: Study Protocol and Statistical Analysis Plan
Document Type: Informed Consent Form
Other Identifiers
Review additional registry numbers or institutional identifiers associated with this trial.
IRB00256185
Identifier Type: -
Identifier Source: org_study_id
More Related Trials
Additional clinical trials that may be relevant based on similarity analysis.