EO Footprint as a Landmark During DAA THA

NCT ID: NCT04623073

Last Updated: 2024-06-27

Study Results

Results pending

The study team has not published outcome measurements, participant flow, or safety data for this trial yet. Check back later for updates.

Basic Information

Get a concise snapshot of the trial, including recruitment status, study phase, enrollment targets, and key timeline milestones.

Recruitment Status

COMPLETED

Total Enrollment

135 participants

Study Classification

OBSERVATIONAL

Study Start Date

2021-01-01

Study Completion Date

2021-04-29

Brief Summary

Review the sponsor-provided synopsis that highlights what the study is about and why it is being conducted.

One of the goals of Total Hip Arthroplasty (THA) is to reconstruct leg length as adequately as possible. In order to achieve this one needs landmarks that are visible both on the templating X ray as well as during surgery. The classical posterior and lateral approaches often rely on the distance from the greater trochanter (GT) to the shoulder of the femoral stem or the distance from the lesser trochanter (LT) to the side of the neck osteotomy. If the surgeon finds out on the digital template that the distance from the GT to the shoulder of the implant should be X mm to achieve equal leg length, than the surgeon can try to reconstruct this during surgery. During the Direct Anterior Approach (DAA) these landmarks usually are not visible or require additional dissection injuring important soft tissue structures along the way. One anatomical structure that appears to be always visible during the DAA is the External Obturator tendon (EO). It was recently confirmed that the level of insertion of the EO onto the proximal femur can also always be determined on pre-operative X rays. It therefore represents one of the few landmarks that is visible both on the templating X ray as well as during DAA THA. Indeed, many hip surgeons, including ourselves, believe that if the shoulder of the femoral stem is near the insertion of the EO leg length cannot be far off. However, there is no clinical data to support this. The investigators would therefore like to the correlate the distance observed intra-operatively to the actual established distance on the post-operative X ray.

Detailed Description

Dive into the extended narrative that explains the scientific background, objectives, and procedures in greater depth.

Conditions

See the medical conditions and disease areas that this research is targeting or investigating.

Coxarthrosis

Study Design

Understand how the trial is structured, including allocation methods, masking strategies, primary purpose, and other design elements.

Observational Model Type

COHORT

Study Time Perspective

RETROSPECTIVE

Study Groups

Review each arm or cohort in the study, along with the interventions and objectives associated with them.

Patients who underwent DAA THA

Patients who underwent DAA THA by a single surgeon who routinely documents the distance from the should of the stem to the upper end of the EO footprint

Total Hip arthroplasty via a Direct Anterior Approach

Intervention Type PROCEDURE

Total Hip arthroplasty via a Direct Anterior Approach

Interventions

Learn about the drugs, procedures, or behavioral strategies being tested and how they are applied within this trial.

Total Hip arthroplasty via a Direct Anterior Approach

Total Hip arthroplasty via a Direct Anterior Approach

Intervention Type PROCEDURE

Eligibility Criteria

Check the participation requirements, including inclusion and exclusion rules, age limits, and whether healthy volunteers are accepted.

Inclusion Criteria

* All patient who underwent THA via DAA by a single surgeon who routinely documents the distance from the shoulder of the stem to the upper border of the EO tendon

Exclusion Criteria

* Distance not noted
* No radiographs available
Eligible Sex

ALL

Accepts Healthy Volunteers

No

Sponsors

Meet the organizations funding or collaborating on the study and learn about their roles.

Universitaire Ziekenhuizen KU Leuven

OTHER

Sponsor Role lead

Responsible Party

Identify the individual or organization who holds primary responsibility for the study information submitted to regulators.

Responsibility Role SPONSOR

Locations

Explore where the study is taking place and check the recruitment status at each participating site.

University Hospitals Leuven - Gasthuisberg

Leuven, , Belgium

Site Status

Countries

Review the countries where the study has at least one active or historical site.

Belgium

References

Explore related publications, articles, or registry entries linked to this study.

Rudiger HA, Fritz B, Impellizzeri FM, Leunig M, Pfirrmann CW, Sutter R. The external obturator footprint as a landmark in total hip arthroplasty through a direct anterior approach: a CT-based analysis. Hip Int. 2019 Jan;29(1):96-101. doi: 10.1177/1120700018761320. Epub 2018 May 21.

Reference Type BACKGROUND
PMID: 29783889 (View on PubMed)

Vles G, Meynen A, De Mulder J, Ghijselings S. The External Obturator Footprint Is a Usable, Accurate, and Reliable Landmark for Stem Depth in Direct Anterior THA. Clin Orthop Relat Res. 2021 Aug 1;479(8):1842-1848. doi: 10.1097/CORR.0000000000001799.

Reference Type DERIVED
PMID: 33944807 (View on PubMed)

Other Identifiers

Review additional registry numbers or institutional identifiers associated with this trial.

S63944

Identifier Type: -

Identifier Source: org_study_id