Short-pulse Subthreshold vs Infrared Micropulse for Diabetic Macular Edema
NCT ID: NCT04505306
Last Updated: 2020-08-10
Study Results
The study team has not published outcome measurements, participant flow, or safety data for this trial yet. Check back later for updates.
Basic Information
Get a concise snapshot of the trial, including recruitment status, study phase, enrollment targets, and key timeline milestones.
COMPLETED
NA
113 participants
INTERVENTIONAL
2015-01-01
2017-01-01
Brief Summary
Review the sponsor-provided synopsis that highlights what the study is about and why it is being conducted.
Related Clinical Trials
Explore similar clinical trials based on study characteristics and research focus.
Micropulse Laser Photocoagulation in Diabetic Macular Edema
NCT07266597
Micropulse Laser in Treatment of Initial and Refractory Cases of Center-Involved Diabetic Macular Edema
NCT07295704
Comparing Conventional Grid Laser Photocoagulation and Subthreshold Micropulse Laser in Diabetic Macular Edema Using OCT Angiography
NCT05416099
Aflibercept With and Without Micropulse Laser in Diabetic Macular Edema
NCT03866746
Comparison of Different Fluence Settings for Yellow Subthreshold Laser Treatment in Diabetic Macular Edema
NCT03571659
Detailed Description
Dive into the extended narrative that explains the scientific background, objectives, and procedures in greater depth.
Materials and Methods: A prospective interventional study from tertiary care eye hospital - King Khaled Eye Specialist Hospital (Riyadh, Saudi Arabia). Patients with center-involving diabetic macular edema were treated with subthreshold laser therapy. Patients in the micropulse group were treated with the 810-nm diode micropulse scanning laser TxCell™ (IRIDEX Corporation, Mountain View, CA, USA). Laser was applied according to manufacturer recommendations for MicroPulseTM in a confluent mode (low intensity/high density) to the entire area of the macular edema. Patients in the short-pulse group were treated with grid pattern laser with 20ms pulse PASCAL laser 532nm (TopCon Medical Laser Systems, Tokyo, Japan) with EndPoint algorithm, which was either 30% or 50% of testing burn. Main outcome measures included best-corrected visual acuity (BCVA) and foveal thickness at baseline and the last follow-up visit.
Conditions
See the medical conditions and disease areas that this research is targeting or investigating.
Study Design
Understand how the trial is structured, including allocation methods, masking strategies, primary purpose, and other design elements.
NON_RANDOMIZED
PARALLEL
TREATMENT
SINGLE
Study Groups
Review each arm or cohort in the study, along with the interventions and objectives associated with them.
Subthreshold Laser 30%
Patients in the SPCW group were treated with grid pattern laser with 20ms pulse PASCAL laser 532nm (TopCon Medical Laser Systems, Tokyo, Japan) with 30% EndPoint algorithm.
Macular Laser
All treatments were performed using SPCW EndPoint 30% and 50% protocols and STMP laser. Patients in the STMP group were treated with the 810-nm diode micropulse scanning laser TxCell™ (IRIDEX Corporation, Mountain View, CA, USA) at 15% duty cycle. Laser was applied in the confluent mode (low intensity/high density) to cover the entire area of the macular edema and leakage as imaged by OCT and/or fundus fluorescein angiography. Patients in the SPCW group were treated with grid pattern laser with 20ms pulse PASCAL laser 532nm (TopCon Medical Laser Systems, Tokyo, Japan) with EndPoint algorithm, which was either 30% or 50% of testing burn with one burn width apart. In both groups, subthreshold power was determined by titrating burn to light (barely visible) burn and switching to either micropulse mode with 15% duty cycle or 30% and 50% EndPoint value.
Subtreshold Laser 50%
Patients in the SPCW group were treated with grid pattern laser with 20ms pulse PASCAL laser 532nm (TopCon Medical Laser Systems, Tokyo, Japan) with 50% EndPoint algorithm.
Macular Laser
All treatments were performed using SPCW EndPoint 30% and 50% protocols and STMP laser. Patients in the STMP group were treated with the 810-nm diode micropulse scanning laser TxCell™ (IRIDEX Corporation, Mountain View, CA, USA) at 15% duty cycle. Laser was applied in the confluent mode (low intensity/high density) to cover the entire area of the macular edema and leakage as imaged by OCT and/or fundus fluorescein angiography. Patients in the SPCW group were treated with grid pattern laser with 20ms pulse PASCAL laser 532nm (TopCon Medical Laser Systems, Tokyo, Japan) with EndPoint algorithm, which was either 30% or 50% of testing burn with one burn width apart. In both groups, subthreshold power was determined by titrating burn to light (barely visible) burn and switching to either micropulse mode with 15% duty cycle or 30% and 50% EndPoint value.
Micropulse Laser
Patients in the STMP group were treated with the 810-nm diode micropulse scanning laser TxCell™ (IRIDEX Corporation, Mountain View, CA, USA) at 15% duty cycle.
Macular Laser
All treatments were performed using SPCW EndPoint 30% and 50% protocols and STMP laser. Patients in the STMP group were treated with the 810-nm diode micropulse scanning laser TxCell™ (IRIDEX Corporation, Mountain View, CA, USA) at 15% duty cycle. Laser was applied in the confluent mode (low intensity/high density) to cover the entire area of the macular edema and leakage as imaged by OCT and/or fundus fluorescein angiography. Patients in the SPCW group were treated with grid pattern laser with 20ms pulse PASCAL laser 532nm (TopCon Medical Laser Systems, Tokyo, Japan) with EndPoint algorithm, which was either 30% or 50% of testing burn with one burn width apart. In both groups, subthreshold power was determined by titrating burn to light (barely visible) burn and switching to either micropulse mode with 15% duty cycle or 30% and 50% EndPoint value.
Interventions
Learn about the drugs, procedures, or behavioral strategies being tested and how they are applied within this trial.
Macular Laser
All treatments were performed using SPCW EndPoint 30% and 50% protocols and STMP laser. Patients in the STMP group were treated with the 810-nm diode micropulse scanning laser TxCell™ (IRIDEX Corporation, Mountain View, CA, USA) at 15% duty cycle. Laser was applied in the confluent mode (low intensity/high density) to cover the entire area of the macular edema and leakage as imaged by OCT and/or fundus fluorescein angiography. Patients in the SPCW group were treated with grid pattern laser with 20ms pulse PASCAL laser 532nm (TopCon Medical Laser Systems, Tokyo, Japan) with EndPoint algorithm, which was either 30% or 50% of testing burn with one burn width apart. In both groups, subthreshold power was determined by titrating burn to light (barely visible) burn and switching to either micropulse mode with 15% duty cycle or 30% and 50% EndPoint value.
Eligibility Criteria
Check the participation requirements, including inclusion and exclusion rules, age limits, and whether healthy volunteers are accepted.
Inclusion Criteria
* clear ocular media
* ETDRS visual acuity \>29 letters (Snellen equivalent of 20/150) or better
* treatment naïve eyes or previously treated with antiangiogenic intravitreal agent(s) more than 6 months ago to allow for long wash-out period
Exclusion Criteria
* previous retinal laser or surgery
* intravitreal steroid use
* any condition that may be associated with a risk of macular edema such as age-related macular degeneration, retinal vein occlusion, vitreomacular traction, epiretinal membrane and others.
18 Years
70 Years
ALL
No
Sponsors
Meet the organizations funding or collaborating on the study and learn about their roles.
King Khaled Eye Specialist Hospital
OTHER_GOV
University of Nebraska
OTHER
Moorfields Eye Hospital Centre Abu Dhabi
OTHER
Responsible Party
Identify the individual or organization who holds primary responsibility for the study information submitted to regulators.
Igor Kozak
Consultant Vitreoretinal Surgeon/Clinical Lead
Locations
Explore where the study is taking place and check the recruitment status at each participating site.
Moorfields Eye Hospital Centre
Abu Dhabi, , United Arab Emirates
Countries
Review the countries where the study has at least one active or historical site.
Other Identifiers
Review additional registry numbers or institutional identifiers associated with this trial.
Moorfields Eye Abu Dhabi
Identifier Type: -
Identifier Source: org_study_id
More Related Trials
Additional clinical trials that may be relevant based on similarity analysis.