Far Infrared Therapy on Peritoneal Function of CAPD Patients

NCT ID: NCT04344067

Last Updated: 2020-04-22

Study Results

Results pending

The study team has not published outcome measurements, participant flow, or safety data for this trial yet. Check back later for updates.

Basic Information

Get a concise snapshot of the trial, including recruitment status, study phase, enrollment targets, and key timeline milestones.

Recruitment Status

UNKNOWN

Clinical Phase

PHASE3

Total Enrollment

100 participants

Study Classification

INTERVENTIONAL

Study Start Date

2016-01-01

Study Completion Date

2020-06-30

Brief Summary

Review the sponsor-provided synopsis that highlights what the study is about and why it is being conducted.

For patients with end-stage renal disease, peritoneal dialysis (PD) has been proven to be an alternative choice compared to hemodialysis as a type of maintenance renal replacement therapy. Despite this, long-term PD is associated with structural membrane changes that are believed to contribute to alterations in solute transport and loss of ultrafiltration. Previous studies have proven that far-infrared (FIR) therapy may improve not only the arteriovenous fistula patency in hemodialysis patients but also abdominal discomfort due to encapsulating peritoneal sclerosis in PD patients. Since there is little information concerning this issue, this study was conducted in order to evaluate the possible effects of FIR therapy on the peritoneal function of patients receiving continuous ambulatory peritoneal dialysis (CAPD). The objective of this study is to evaluate the effect of FIR therapy on the peritoneal function, protein loss, and ultrafiltration capacity of CAPD patients.

Detailed Description

Dive into the extended narrative that explains the scientific background, objectives, and procedures in greater depth.

A total of 100 CAPD patients will be enrolled in this study, including 50 in treatment group who will receive FIR therapy for 6 months and 50 in control group. Many parameters of blood and urine samples as well as ultrafiltration amount, dialysate urea nitrogen, creatinine, Na+, K+, total protein, CA-125, and glucose degradation product (GDP) for the dialysate effluent of not only the first and last exchanges but also the total exchanges of daily PD regimen will be measured for both groups at day 1 and 6th month. However, only the FIR group will receive tests of blood, urine and dialysate on day 2. The significance of the study is that patients might benefit from the prophylactic therapeutic effects of FIR therapy, leading to the reduction of the hospitalization costs and the need for interventional procedures in CAPD patient care in Taiwan.

Conditions

See the medical conditions and disease areas that this research is targeting or investigating.

End-stage Renal Disease

Study Design

Understand how the trial is structured, including allocation methods, masking strategies, primary purpose, and other design elements.

Allocation Method

RANDOMIZED

Intervention Model

PARALLEL

Participants are assigned to either the control group or the treatment (far infrared therapy) group
Primary Study Purpose

TREATMENT

Blinding Strategy

NONE

Study Groups

Review each arm or cohort in the study, along with the interventions and objectives associated with them.

Control Group

Group Type NO_INTERVENTION

No interventions assigned to this group

Far Infrared Therapy Group

In this study, the top radiator of the far infrared emitter was set at a height of 25 cm above the umbilicus with a treatment time of 40 minutes during the initial 1 hour of both the first daily and the last night-time indwelling dialysate of each daily regular peritoneal dialysis regimen.

Group Type EXPERIMENTAL

Far Infrared Therapy

Intervention Type DEVICE

The WSTM TY101 FIR emitter (WS Far Infrared Medical Technology Co., Ltd., Taipei, Taiwan) was used to conduct FIR therapy in this study. The electrified ceramic plates of the emitter generated electromagnetic waves with wavelengths in the range between 3 and 25 μm (a peak between 5 to 6 μm). The irradiating power density is 10 and 20 milliwatt (mw) /cm2 when the top radiator was set at a distance of 30 and 20 cm above the skin surface respectively.

Interventions

Learn about the drugs, procedures, or behavioral strategies being tested and how they are applied within this trial.

Far Infrared Therapy

The WSTM TY101 FIR emitter (WS Far Infrared Medical Technology Co., Ltd., Taipei, Taiwan) was used to conduct FIR therapy in this study. The electrified ceramic plates of the emitter generated electromagnetic waves with wavelengths in the range between 3 and 25 μm (a peak between 5 to 6 μm). The irradiating power density is 10 and 20 milliwatt (mw) /cm2 when the top radiator was set at a distance of 30 and 20 cm above the skin surface respectively.

Intervention Type DEVICE

Eligibility Criteria

Check the participation requirements, including inclusion and exclusion rules, age limits, and whether healthy volunteers are accepted.

Inclusion Criteria

* Chronic peritoneal dialysis patients who have not received any FIR therapy within the previous 12 months
* Patients on a standard continuous ambulatory peritoneal dialysis (CAPD) (1.5-2 L; 4-5 exchanges/day) or ambulatory peritoneal dialysis (APD) program

Exclusion Criteria

* History of CAPD-related peritonitis within 3 months prior to the study period;
* History of cerebrovascular accident or myocardial infarction or interventional procedure (percutaneous transluminal coronary angioplasty or stent) for coronary artery disease within the 3 months prior to the study
Minimum Eligible Age

18 Years

Maximum Eligible Age

90 Years

Eligible Sex

ALL

Accepts Healthy Volunteers

No

Sponsors

Meet the organizations funding or collaborating on the study and learn about their roles.

Taipei Veterans General Hospital, Taiwan

OTHER_GOV

Sponsor Role lead

Responsible Party

Identify the individual or organization who holds primary responsibility for the study information submitted to regulators.

Responsibility Role SPONSOR

Principal Investigators

Learn about the lead researchers overseeing the trial and their institutional affiliations.

Chih-Ching Lin, MD, PhD

Role: PRINCIPAL_INVESTIGATOR

Taipei Veterans General Hospital, Taiwan

Locations

Explore where the study is taking place and check the recruitment status at each participating site.

Taipei Veterans General Hospital

Taipei, , Taiwan

Site Status RECRUITING

Countries

Review the countries where the study has at least one active or historical site.

Taiwan

Facility Contacts

Find local site contact details for specific facilities participating in the trial.

Chih-Ching Lin, MD, PhD

Role: primary

02-2871-2121 ext. 2993

References

Explore related publications, articles, or registry entries linked to this study.

Lin CC, Chang CF, Lai MY, Chen TW, Lee PC, Yang WC. Far-infrared therapy: a novel treatment to improve access blood flow and unassisted patency of arteriovenous fistula in hemodialysis patients. J Am Soc Nephrol. 2007 Mar;18(3):985-92. doi: 10.1681/ASN.2006050534. Epub 2007 Jan 31.

Reference Type BACKGROUND
PMID: 17267744 (View on PubMed)

Lin CC, Liu XM, Peyton K, Wang H, Yang WC, Lin SJ, Durante W. Far infrared therapy inhibits vascular endothelial inflammation via the induction of heme oxygenase-1. Arterioscler Thromb Vasc Biol. 2008 Apr;28(4):739-45. doi: 10.1161/ATVBAHA.107.160085. Epub 2008 Jan 17.

Reference Type BACKGROUND
PMID: 18202320 (View on PubMed)

Lin CC, Yang WC, Chen MC, Liu WS, Yang CY, Lee PC. Effect of far infrared therapy on arteriovenous fistula maturation: an open-label randomized controlled trial. Am J Kidney Dis. 2013 Aug;62(2):304-11. doi: 10.1053/j.ajkd.2013.01.015. Epub 2013 Mar 6.

Reference Type BACKGROUND
PMID: 23474008 (View on PubMed)

Lin CC, Chung MY, Yang WC, Lin SJ, Lee PC. Length polymorphisms of heme oxygenase-1 determine the effect of far-infrared therapy on the function of arteriovenous fistula in hemodialysis patients: a novel physicogenomic study. Nephrol Dial Transplant. 2013 May;28(5):1284-93. doi: 10.1093/ndt/gfs608. Epub 2013 Jan 22.

Reference Type BACKGROUND
PMID: 23345623 (View on PubMed)

Other Identifiers

Review additional registry numbers or institutional identifiers associated with this trial.

2015-09-002B

Identifier Type: -

Identifier Source: org_study_id

More Related Trials

Additional clinical trials that may be relevant based on similarity analysis.

PD Catheter Data Collection
NCT07156123 NOT_YET_RECRUITING
Light Therapy in End Stage Kidney Disease
NCT06310161 NOT_YET_RECRUITING NA