Within and Between-rater Reproducibility and Validity of a Novel Portable Laser Height Meter

NCT ID: NCT04070638

Last Updated: 2019-10-04

Study Results

Results pending

The study team has not published outcome measurements, participant flow, or safety data for this trial yet. Check back later for updates.

Basic Information

Get a concise snapshot of the trial, including recruitment status, study phase, enrollment targets, and key timeline milestones.

Recruitment Status

COMPLETED

Total Enrollment

32 participants

Study Classification

OBSERVATIONAL

Study Start Date

2019-08-26

Study Completion Date

2019-08-28

Brief Summary

Review the sponsor-provided synopsis that highlights what the study is about and why it is being conducted.

Height may be used to calculate body mass index and reference interval for normal lung function, together with serving as an indicator for possible vertebral fractures in osteoporosis and growth retardation in children. Height is typically measured using the "gold standard" a fixed stadiometer in a clinical setting. However, newer studies have investigated alternative ways of measuring height using portable measuring devices with laser distance metres. The advantage with this type of measure is the ability to potentially perform reliable measure in settings outside clinical controlled settings. Recently, a measuring device which required adjustments of measuring axes by hand was developed, which resulted in a measurement error of 0.35 cm compared with 0.20-0.30 cm in fixed stadiometers. In order to optimise this, it was suggested that future measuring devices using laser distance meters should be fixed in one or more measurement axes. Thus, a novel portable height device, which is fixated in two axes using a laser distance metre has been developed.

Detailed Description

Dive into the extended narrative that explains the scientific background, objectives, and procedures in greater depth.

Objectives:

Primary objective: To investigate inter- and intra-rater reproducibility of the portable height device

Secondary objectives:To assess agreement between the portable height device and wall-fixed digital stadiometer.

\_\_\_\_

Participants: Approximately 30 adults, 18+ years old men and women in the study is expected to be enrolled. Participants will be recruited through convenience sampling in order to maximise recruitment efforts during the time of the study. Data on gender, age, and height will be collected.

\_\_\_\_

Ethics: Written informed consent will be obtained from all participants prior to the study. The local ethics committee will be consulted for approval of the study. Approval will also be obtained from the Danish Data Protection Agency.

\_\_\_\_

Measuring devices:

Portable laser measuring device: A laser distance meter (Bosch Zamo, Robert Bosch GmbH, Gerlingen-Schillerhöhe, Germany) will be mounted perpendicularly to the end of a wooden lath (3x4x50 cm). The other end of the lath will be mounted perpendicular to a T-shaped metal plate which will fixate the x- and z-axis of the laser measuring device. The portable height device will measure vertically down in its z-axis from the participant's vertex to the floor in front of the participant.

Stadiometer (reference standard): a fixed stadiometer will be used as a reference (Harpenden Stadiometer, Holtain Limited, Crosswell, UK).

\_\_\_\_

Procedure:

Measurements will be performed at Aalborg University Hospital, Aalborg, Denmark. Two raters will independently perform height measurements in two separate rooms with each measuring device (portable height device and fixed stadiometer) on all participants. Each rater will perform three measures per device. During measurements, participants will be asked to stand flat on the floor (hard surface) without shoes. Furthermore, participants will be asked to stand with their heels positioned together and against the wall during both type of measurements. Each rater will make sure that participants' heads are be positioned in the Frankfurt plane, and encourage participants to stand with a straight back against the wall.

Stadiometer (reference standard): The measuring device will be pulled down to the skull. Afterwards, the participant will be asked to take a deep breath and hold it, after which the measurement will be performed.

Portable laser measuring device: The lath with the laser distance meter will be placed on top of the participant's vertex and fixated in two axes by holding the T-shaped piece against the wall. The lath will be rotated until the laser distance meter points vertically, which is done using a bubble level mounted on the end of the lath. The laser distance meter will be activated by clicking on the "START" button. Participants are asked to take a deep breath and hold it, after which the measurement will be locked and recorded. Following each measurement, the participant will take a step away from the measuring area and afterwards step back again to replicate the measurement procedure.

Blinding: All 30 participants will be measured using the laser distance meter first by each rater. When this stage is complete, measurements will be secured and inaccessible, in order to blind the raters when performing stadiometer measurements afterwards. It is assumed that each rater will not be able to remember each participants' height when 30 participants are measured consecutively. After the stadiometer measurements have been performed, data will also be secured and inaccessible. Afterwards, this entire procedure will be repeated once more. Measurements will be collected using a data capturing tool Research electronic data capture (REDCap).

\_\_\_\_

Statistics:

Participants: Age will be reported in mean with standard deviations, and gender will be reported in proportions. Both height measures will have 95% confidence intervals reported.

Agreement:Mean of all three measurements per rater per measuring device per participants will be calculated. The difference between the means will be calculated by subtracting the mean laser measurement from the mean stadiometer measurement. This will also be performed with only the mean of the two first measurements, and finally also the first measurement. Thus, it would be possible to evaluate whether one measurement would have similar agreement with two or three measurements. Bland Altman plots with limits of agreement (LOA) will be generated together with standard error of measurements (SEM) and coefficient of variation (c.v) for all the above-mentioned combinations.

Reliability: Intraclass Correlation Coefficients (ICC) with 95% confidence intervals between measuring devices will be calculated.

Software: Statistics will be performed using Microsoft Excel for Mac version 16.28 (Microsoft Office, Microsoft Corporation, WA) and IBM SPSS Statistics for MacOS version 25.0 (IBM Corporation, Armonk, NY).

\_\_\_\_

Conflicts of interest: The authors report no conflicts of interest.

\_\_\_\_

Dissemination: This study is planned to be published in an English-language journal. The reporting of the study will follow the current guidelines for reliability and agreement studies (GRRAS).

Conditions

See the medical conditions and disease areas that this research is targeting or investigating.

Body Height Lasers Reproducibility of Results Anthropometry

Study Design

Understand how the trial is structured, including allocation methods, masking strategies, primary purpose, and other design elements.

Observational Model Type

OTHER

Study Time Perspective

CROSS_SECTIONAL

Eligibility Criteria

Check the participation requirements, including inclusion and exclusion rules, age limits, and whether healthy volunteers are accepted.

Inclusion Criteria

* Age 18 years or older.

Exclusion Criteria

* None
Minimum Eligible Age

18 Years

Eligible Sex

ALL

Accepts Healthy Volunteers

Yes

Sponsors

Meet the organizations funding or collaborating on the study and learn about their roles.

Odense University Hospital

OTHER

Sponsor Role collaborator

Aalborg University Hospital

OTHER

Sponsor Role lead

Responsible Party

Identify the individual or organization who holds primary responsibility for the study information submitted to regulators.

Gustav Valentin Blichfeldt Sørensen

Principal Investigator

Responsibility Role PRINCIPAL_INVESTIGATOR

Principal Investigators

Learn about the lead researchers overseeing the trial and their institutional affiliations.

Stig Andersen, MD, PhD

Role: STUDY_DIRECTOR

Aalborg University Hospital

Locations

Explore where the study is taking place and check the recruitment status at each participating site.

Aalborg University Hospital

Aalborg, , Denmark

Site Status

Countries

Review the countries where the study has at least one active or historical site.

Denmark

References

Explore related publications, articles, or registry entries linked to this study.

Deurenberg P, Weststrate JA, Seidell JC. Body mass index as a measure of body fatness: age- and sex-specific prediction formulas. Br J Nutr. 1991 Mar;65(2):105-14. doi: 10.1079/bjn19910073.

Reference Type BACKGROUND
PMID: 2043597 (View on PubMed)

Renstrom SB, Andersen CS, Pedersen CH, Madsen FF. Correct measurement of height is important when assessing lung function values. Dan Med J. 2012 Feb;59(2):A4376.

Reference Type BACKGROUND
PMID: 22293049 (View on PubMed)

Siminoski K, Warshawski RS, Jen H, Lee K. The accuracy of historical height loss for the detection of vertebral fractures in postmenopausal women. Osteoporos Int. 2006 Feb;17(2):290-6. doi: 10.1007/s00198-005-2017-y. Epub 2005 Sep 6.

Reference Type BACKGROUND
PMID: 16143833 (View on PubMed)

Duggan MB. Anthropometry as a tool for measuring malnutrition: impact of the new WHO growth standards and reference. Ann Trop Paediatr. 2010;30(1):1-17. doi: 10.1179/146532810X12637745451834.

Reference Type BACKGROUND
PMID: 20196929 (View on PubMed)

Voss LD, Bailey BJ, Cumming K, Wilkin TJ, Betts PR. The reliability of height measurement (the Wessex Growth Study). Arch Dis Child. 1990 Dec;65(12):1340-4. doi: 10.1136/adc.65.12.1340.

Reference Type BACKGROUND
PMID: 2270942 (View on PubMed)

Mayol-Kreiser SN, Garcia-Turner VM, Johnston CS. Examining the utility of a laser device for measuring height in free-living adults and children. Nutr J. 2015 Sep 8;14:93. doi: 10.1186/s12937-015-0082-4.

Reference Type BACKGROUND
PMID: 26350125 (View on PubMed)

Bauman A, Ernst K, Hayden M, Roe DJ, Murray R, Agawo M, Munga S, Schmahl E, Taren D. Assessing Community Health: An Innovative Tool for Measuring Height and Length. J Trop Pediatr. 2018 Apr 1;64(2):146-150. doi: 10.1093/tropej/fmx046.

Reference Type BACKGROUND
PMID: 28673047 (View on PubMed)

Harris PA, Taylor R, Thielke R, Payne J, Gonzalez N, Conde JG. Research electronic data capture (REDCap)--a metadata-driven methodology and workflow process for providing translational research informatics support. J Biomed Inform. 2009 Apr;42(2):377-81. doi: 10.1016/j.jbi.2008.08.010. Epub 2008 Sep 30.

Reference Type BACKGROUND
PMID: 18929686 (View on PubMed)

Kottner J, Audige L, Brorson S, Donner A, Gajewski BJ, Hrobjartsson A, Roberts C, Shoukri M, Streiner DL. Guidelines for Reporting Reliability and Agreement Studies (GRRAS) were proposed. Int J Nurs Stud. 2011 Jun;48(6):661-71. doi: 10.1016/j.ijnurstu.2011.01.016. Epub 2011 Apr 23.

Reference Type BACKGROUND
PMID: 21514934 (View on PubMed)

Provided Documents

Download supplemental materials such as informed consent forms, study protocols, or participant manuals.

Document Type: Study Protocol and Statistical Analysis Plan

View Document

Other Identifiers

Review additional registry numbers or institutional identifiers associated with this trial.

2019-100

Identifier Type: -

Identifier Source: org_study_id

More Related Trials

Additional clinical trials that may be relevant based on similarity analysis.

Build Better Bones With Exercise
NCT01761084 COMPLETED NA
Osteoporosis Patient Education in Denmark
NCT05401968 ACTIVE_NOT_RECRUITING NA
Osteoporosis and Colles Fracture
NCT00225004 TERMINATED