The Effects Of Auditory Interventions On Pain And Comfort In Premature Infants
NCT ID: NCT04067206
Last Updated: 2020-01-27
Study Results
The study team has not published outcome measurements, participant flow, or safety data for this trial yet. Check back later for updates.
Basic Information
Get a concise snapshot of the trial, including recruitment status, study phase, enrollment targets, and key timeline milestones.
COMPLETED
NA
256 participants
INTERVENTIONAL
2017-09-10
2019-04-13
Brief Summary
Review the sponsor-provided synopsis that highlights what the study is about and why it is being conducted.
Related Clinical Trials
Explore similar clinical trials based on study characteristics and research focus.
Premature Newborn Pain Management: The Effects of Breast Milk Odor and White Noise
NCT05444608
Pain Perception Associated With Orogastric Tube Insertion in Preterm Infants
NCT04678570
Vibration and During Heel Lance Procedures in Newborns
NCT04674982
The Effect of 3 Different Auditory Applications on Newborn Heel Prick Procedure
NCT06167551
Maternal Voice on Alleviating Pain in Premature Undergoing Heel Lance Procedure and Enhancing Mother-Infant Bonding
NCT04158206
Detailed Description
Dive into the extended narrative that explains the scientific background, objectives, and procedures in greater depth.
Conditions
See the medical conditions and disease areas that this research is targeting or investigating.
Study Design
Understand how the trial is structured, including allocation methods, masking strategies, primary purpose, and other design elements.
RANDOMIZED
PARALLEL
SUPPORTIVE_CARE
NONE
Study Groups
Review each arm or cohort in the study, along with the interventions and objectives associated with them.
Recorded mothers' voice group.
The mothers of the babies were given voice recorders and asked to record their voice in a comfortable room saying whatever they wanted to their baby. Each mother recorded her voice for 3-5 minutes. The voice recorder was placed at the baby's foot five minutes before the procedure and then played to the baby during the procedure.The sound level was adjusted to 50 decibels using the Benetech Digital Sound Level Meter for the mother's voice and white noise groups.
RECORDED MOTHER'S VOICE
The mothers of the babies were given voice recorders and asked to record their voice in a comfortable room saying whatever they wanted to their baby. Each mother recorded her voice for 3-5 minutes. The voice recorder was placed at the baby's foot five minutes before the procedure and then played to the baby during the procedure.The sound level was adjusted to 50 decibels using the Benetech Digital Sound Level Meter for the mother's voice and white noise groups.
White Noise
The white noise was started five minutes before the heel lance and was played to the baby during the procedure. Dr. Harvery Karp's "The Happiest Baby," which consists of only intrauterine sounds, was used. The speakers were placed at a distance of about 30 cm from the foot of the neonate. The sound level was adjusted to 50 decibels using the Benetech Digital Sound Level Meter for the mother's voice and white noise groups.
White Noise
The white noise was started five minutes before the heel lance and was played to the baby during the procedure. Dr. Harvery Karp's "The Happiest Baby," which consists of only intrauterine sounds, was used. The speakers were placed at a distance of about 30 cm from the foot of the neonate. The sound level was adjusted to 50 decibels using the Benetech Digital Sound Level Meter for the mother's voice and white noise groups.
MiniMuffs
MiniMuffs placed on their ears five minutes before the procedure to reduce the environmental noise. Latus MiniMuffs - Neonatal Noise Attenuators have been developed for newborns and premature babies. MiniMuffs protect the sensitive ears of the premature and provide a safe environment for healthy development.
MiniMuff
MiniMuffs placed on their ears five minutes before the procedure to reduce the environmental noise. Latus MiniMuffs - Neonatal Noise Attenuators have been developed for newborns and premature babies. MiniMuffs protect the sensitive ears of the premature and provide a safe environment for healthy development.
Control Group
The control group who were administered standard care.
No interventions assigned to this group
Interventions
Learn about the drugs, procedures, or behavioral strategies being tested and how they are applied within this trial.
RECORDED MOTHER'S VOICE
The mothers of the babies were given voice recorders and asked to record their voice in a comfortable room saying whatever they wanted to their baby. Each mother recorded her voice for 3-5 minutes. The voice recorder was placed at the baby's foot five minutes before the procedure and then played to the baby during the procedure.The sound level was adjusted to 50 decibels using the Benetech Digital Sound Level Meter for the mother's voice and white noise groups.
White Noise
The white noise was started five minutes before the heel lance and was played to the baby during the procedure. Dr. Harvery Karp's "The Happiest Baby," which consists of only intrauterine sounds, was used. The speakers were placed at a distance of about 30 cm from the foot of the neonate. The sound level was adjusted to 50 decibels using the Benetech Digital Sound Level Meter for the mother's voice and white noise groups.
MiniMuff
MiniMuffs placed on their ears five minutes before the procedure to reduce the environmental noise. Latus MiniMuffs - Neonatal Noise Attenuators have been developed for newborns and premature babies. MiniMuffs protect the sensitive ears of the premature and provide a safe environment for healthy development.
Eligibility Criteria
Check the participation requirements, including inclusion and exclusion rules, age limits, and whether healthy volunteers are accepted.
Inclusion Criteria
* Non-supported by a mechanical ventilator or NCPAP
* Started to feed
* Within the first 10 days of postnatal
Exclusion Criteria
* Apgar score was less than 5 in the 1st-minute and less than 7 in the 5th-minute
* Received a sedative, muscle relaxant, corticosteroid, or analgesic therapy,
* First blood sampling attempt was unsuccessful
* MiniMuffs moved from their ears during the procedure
* Mothers who had problems recording their voice.
31 Weeks
36 Weeks
ALL
Yes
Sponsors
Meet the organizations funding or collaborating on the study and learn about their roles.
Ege University
OTHER
Responsible Party
Identify the individual or organization who holds primary responsibility for the study information submitted to regulators.
Ayşe Kahraman
Assistant Professor
Principal Investigators
Learn about the lead researchers overseeing the trial and their institutional affiliations.
Zümrüt Başbakkal, Professor
Role: STUDY_DIRECTOR
Ege University
Locations
Explore where the study is taking place and check the recruitment status at each participating site.
Ege University Faculty of Nursing
Izmir, , Turkey (Türkiye)
Countries
Review the countries where the study has at least one active or historical site.
References
Explore related publications, articles, or registry entries linked to this study.
Chirico G, Cabano R, Villa G, Bigogno A, Ardesi M, Dioni E. Randomised study showed that recorded maternal voices reduced pain in preterm infants undergoing heel lance procedures in a neonatal intensive care unit. Acta Paediatr. 2017 Oct;106(10):1564-1568. doi: 10.1111/apa.13944. Epub 2017 Jul 5.
Kucukoglu S, Aytekin A, Celebioglu A, Celebi A, Caner I, Maden R. Effect of White Noise in Relieving Vaccination Pain in Premature Infants. Pain Manag Nurs. 2016 Dec;17(6):392-400. doi: 10.1016/j.pmn.2016.08.006. Epub 2016 Oct 15.
Other Identifiers
Review additional registry numbers or institutional identifiers associated with this trial.
17HEF001
Identifier Type: -
Identifier Source: org_study_id
More Related Trials
Additional clinical trials that may be relevant based on similarity analysis.