A Novel Walking Cane With Haptic Biofeedback Reduces Degenerative Loading in the Arthritic Knee
NCT ID: NCT03900052
Last Updated: 2019-04-04
Study Results
The study team has not published outcome measurements, participant flow, or safety data for this trial yet. Check back later for updates.
Basic Information
Get a concise snapshot of the trial, including recruitment status, study phase, enrollment targets, and key timeline milestones.
COMPLETED
NA
21 participants
INTERVENTIONAL
2015-06-25
2017-07-10
Brief Summary
Review the sponsor-provided synopsis that highlights what the study is about and why it is being conducted.
Related Clinical Trials
Explore similar clinical trials based on study characteristics and research focus.
Walking Aids in the Management of Knee Osteoarthritis
NCT00223795
Gait Retraining to Reduce Knee Osteoarthritis Pain
NCT01397981
Effects of Movement Retraining on Knee Loading in Individuals With Knee Osteoarthritis
NCT06208631
Knee Biofeedback Rehabilitation Interface for Game-based Home Therapy for Patients With Knee Osteoarthritis
NCT04187092
Self-Management of Osteoarthritis
NCT00288912
Detailed Description
Dive into the extended narrative that explains the scientific background, objectives, and procedures in greater depth.
* Participant biometrics, such as height, weight, and age will be collected in addition to information about OA and cane use history. Participants will complete the Western Ontario and McMaster Universities Osteoarthritis Index (WOMAC) questionnaire, from which scores between 0 and 96 can be used to evaluate the impact of knee OA on the individual's quality of life.
* A haptic biofeedback cane was designed and manufactured to measure the user applied axial cane load, compare the load to the targeted 20% BW threshold, and then deliver a vibrotactile feedback in the cane handle when the loading was greater than threshold. The cane data acquisition was temporally synchronized to the motion analysis system and recorded axial cane loads at 100 Hz for later analysis. The haptic biofeedback cane consisted of a conventional bariatric walking cane (Patterson Medical Ltd) with a loadcell (Digi-Key100 LBS. Load Cell) placed inside a 3D printed modular cane foot. A microcontroller (Sparkfun™ Pro Micro), SD disk storage (Sparkfun™ OpenLog), eccentric rotating mass vibration motor (model 306-109, Precision Microdrives Limited), USB communications port, and battery completed the system.
* Each participant will attend a single laboratory data collection session for the acquisition of kinematic, kinetic, and biometric data. First, the participant will be asked to walk 20 m down a hallway with a conventional cane to establish a self-selected walking speed (SSWS). Participants will then change into motion capture conducive clothing and retro-reflective markers were placed using a modified Plug-In-Gait model with additional markers on the foot, thigh, and shank, via the Kadaba Model, for observation of the Kenn Adduction Moment (KAM) during level ground walking. Markers will also placed on the cane to track its motion.
* Participants will then be instructed to walk at their SSWS along an approximately 9-meter walkway containing five force-plates but will remain naïve as to the purpose of the plates throughout data collection, to avoid influencing gait. Data were collected under each of the following five conditions: 1) naïve, 2) scale training, 3) scale recall, 4) haptics training, and 5) haptics-only (Table 2). The order of the scale and haptics conditions was randomized at the beginning of data collection to avoid a learning bias. During all conditions the instrumented cane will be used, and axial loading recoded. However, haptic biofeedback from the cane will only be provided in the haptic conditions.
* For scale and haptic conditions, the participants will be instructed to hold the cane in the hand opposite their most affected knee. Before the recall and haptics-only conditions, a five-minute break will be given to test short-term instruction retention. For each condition, between five and eight successful steps will be collected. A successful walk trial is defined as at least one gait cycle with the affected limb's foot cleanly striking the force plate and the cane contacting the floor, not the force plate, during stance phase. Successful trials will also have to be within ± 10% of the subjects SSWS.
* Naïve condition
* Participants will be instructed to "walk across the lab and use the cane as is typical." During these trials the cane will record axial load but provided no biofeedback (i.e. the cane will act as a conventional cane).
* Scale conditions
* During scale training, participants will practice applying 20% BW to their canes while standing, using a beam scale set to the correct weight, until they feel comfortable recreating the technique. Participants then practice applying the 20% BW to their canes while walking, no external feedback regarding the load applied to the cane will be provided, however feedback on cane technique will be. Data will be collected during these walking trials. In the scale recall trials participants are to load the cane to 20% during walking without any feedback from a scale or the cane.
* Haptic conditions
* During haptic training, participants will be instructed to walk around the lab and load the cane during each step until they feel a vibration in the handle. The participants will then familiarize themselves with the biofeedback mechanism and practice loading the haptic cane while walking around the lab space. In the haptic-only trails participants will be instructed to load the cane during walking until they feel a vibration in the handle
* Three-dimensional kinematics will be collected using a camera 12 Vicon Nexus system (Vicon Motion Systems, Oxford, United Kingdom) with a sampling frequency of 120 Hz. Five force plates (AMTI) sampling at 1200 Hz were used for collection of ground reaction forces (GRFs) and identification of gait events during walking trials. Two time gates placed 2 meters apart will measure walking speed.
* The KAM will be calculated for the arthritic knee during stance phase of each processed step using the inverse kinematics packages in Visual 3D then normalized to body weight and height. KAMs will then be exported to MATLAB for further processing and analysis. Cane load will be normalized by weight and peak cane load per step will be determined in MATLAB. PKAM is calculated as highest KAM and KAAI is calculated as the area under the KAM curve.
Conditions
See the medical conditions and disease areas that this research is targeting or investigating.
Study Design
Understand how the trial is structured, including allocation methods, masking strategies, primary purpose, and other design elements.
RANDOMIZED
CROSSOVER
2B: Scale recall - Conventional cane with no further instruction or practice given 3A: Haptics training - Haptic biofeedback cane with explanation and training. 3B: Haptics recall - Haptic biofeedback cane with no further instruction or practice given.
DEVICE_FEASIBILITY
NONE
Study Groups
Review each arm or cohort in the study, along with the interventions and objectives associated with them.
Naïve
Conventional cane with no instruction given
No interventions assigned to this group
Scale training
Conventional cane, scale training, and instruction on proper cane use
typical cane
Typical training cane loading training
Scale recall
Conventional cane with no further instruction or practice given
typical cane
Typical training cane loading training
Haptics training
Haptic biofeedback cane with explanation and training.
Haptic cane
• A haptic biofeedback cane was designed and manufactured to measure the user applied axial cane load, compare the load to the targeted 20% BW threshold, and then deliver a vibrotactile feedback in the cane handle when the loading was greater than threshold. The cane data acquisition was temporally synchronized to the motion analysis system and recorded axial cane loads at 100 Hz for later analysis. The haptic biofeedback cane consisted of a conventional bariatric walking cane (Patterson Medical Ltd) with a loadcell (Digi-Key100 LBS. Load Cell) placed inside a 3D printed modular cane foot. A microcontroller (Sparkfun™ Pro Micro), SD disk storage (Sparkfun™ OpenLog), eccentric rotating mass vibration motor (model 306-109, Precision Microdrives Limited), USB communications port, and battery completed the system.
Haptics recall
Haptic biofeedback cane with no further instruction or practice given.
Haptic cane
• A haptic biofeedback cane was designed and manufactured to measure the user applied axial cane load, compare the load to the targeted 20% BW threshold, and then deliver a vibrotactile feedback in the cane handle when the loading was greater than threshold. The cane data acquisition was temporally synchronized to the motion analysis system and recorded axial cane loads at 100 Hz for later analysis. The haptic biofeedback cane consisted of a conventional bariatric walking cane (Patterson Medical Ltd) with a loadcell (Digi-Key100 LBS. Load Cell) placed inside a 3D printed modular cane foot. A microcontroller (Sparkfun™ Pro Micro), SD disk storage (Sparkfun™ OpenLog), eccentric rotating mass vibration motor (model 306-109, Precision Microdrives Limited), USB communications port, and battery completed the system.
Interventions
Learn about the drugs, procedures, or behavioral strategies being tested and how they are applied within this trial.
Haptic cane
• A haptic biofeedback cane was designed and manufactured to measure the user applied axial cane load, compare the load to the targeted 20% BW threshold, and then deliver a vibrotactile feedback in the cane handle when the loading was greater than threshold. The cane data acquisition was temporally synchronized to the motion analysis system and recorded axial cane loads at 100 Hz for later analysis. The haptic biofeedback cane consisted of a conventional bariatric walking cane (Patterson Medical Ltd) with a loadcell (Digi-Key100 LBS. Load Cell) placed inside a 3D printed modular cane foot. A microcontroller (Sparkfun™ Pro Micro), SD disk storage (Sparkfun™ OpenLog), eccentric rotating mass vibration motor (model 306-109, Precision Microdrives Limited), USB communications port, and battery completed the system.
typical cane
Typical training cane loading training
Eligibility Criteria
Check the participation requirements, including inclusion and exclusion rules, age limits, and whether healthy volunteers are accepted.
Inclusion Criteria
* Between 35-80 years
* Stand and/or walk for at least 30 minutes without difficulty
* Have a VA medical record
Exclusion Criteria
* Lateral OA greater than medial OA
* Inadequate cognitive or language function to consent or participate
* BMI \> 40
* pregnancy
35 Years
80 Years
ALL
Yes
Sponsors
Meet the organizations funding or collaborating on the study and learn about their roles.
VA Puget Sound Health Care System
FED
Responsible Party
Identify the individual or organization who holds primary responsibility for the study information submitted to regulators.
Patrick Aubin
Research Health Scientist Specialist
Other Identifiers
Review additional registry numbers or institutional identifiers associated with this trial.
RX001926
Identifier Type: -
Identifier Source: org_study_id
More Related Trials
Additional clinical trials that may be relevant based on similarity analysis.