Comparison of Automated Oxygen Control With and Without Automated Pressure Control in Preterm Ventilated Infants.
NCT ID: NCT03865069
Last Updated: 2020-07-20
Study Results
The study team has not published outcome measurements, participant flow, or safety data for this trial yet. Check back later for updates.
Basic Information
Get a concise snapshot of the trial, including recruitment status, study phase, enrollment targets, and key timeline milestones.
COMPLETED
NA
19 participants
INTERVENTIONAL
2019-11-01
2020-07-12
Brief Summary
Review the sponsor-provided synopsis that highlights what the study is about and why it is being conducted.
Related Clinical Trials
Explore similar clinical trials based on study characteristics and research focus.
Optimising Ventilation in Preterms With Closed-loop Oxygen Control
NCT05030337
Arterial Oxygen Saturation on Ventilatory Stability in Extremely Premature Infants
NCT03695900
Closed-loop Oxygen Control in Ventilated Infants Born at or Near Term
NCT05017727
Maintaining Optimal HVNI Delivery Using Automatic Titration of Oxygen in Preterm Infants
NCT05030012
Initial Oxygen Concentration at Birth in Late-Preterm Infants
NCT07315594
Detailed Description
Dive into the extended narrative that explains the scientific background, objectives, and procedures in greater depth.
Preterm infants have frequent fluctuations in SpO2 due to their respiratory instability requiring frequent adjustments of FiO2 \[6\]. Consequently, these particularly vulnerable infants spend significant time with SpO2 outside intended range and are often exposed to extremes of hypoxemia and hyperoxaemia. To this end, it is now possible to have automated control of inspired oxygen using a device (CLiO2™) incorporated in Avea® ventilator. The safety, feasibility and efficacy of this device have already been established \[7-12\]. There has been further improvement in the algorithm of the pulse oximeter incorporated in Avea® ventilator to achieve a better normative distribution around the median SpO2 value\[13\]. Automated control of FiO2 significantly improves compliance of oxygen saturation targeting and significantly reduces exposure to hypoxemia as well as hyperoxaemia \[7-12, 14\].
Another mechanism of respiratory instability and hypoxemia is wide fluctuation in tidal volume in ventilated preterm infants. Volume-targeted modes of ventilation have been used for several years to aim to more accurately control the tidal volumes delivered to ventilated infants. Jain et al showed a reduction in duration of hypoxaemic events when using volume targeted ventilation as compared to pressure controlled ventilation\[15\]. Avea ventilators can deliver several types of volume-targeted ventilation, including Volume Guarantee® (VG) and volume controlled ventilation (VCV). VCV aims to deliver a set volume of gas irrespective of the lung compliance whereas VG® uses a servo-controlled feedback loop to automatically adjust inspiratory pressures to aim to control tidal volume delivery.
There is no data available currently on whether automatic control algorithm adjustment of inspired oxygen and tidal volume together leads to further improvements in maintaining SpO2 profile within prescribed target range and more importantly to reduce episodes of prolonged hypoxemia and hyperoxaemia in preterm ventilated infants. Hence the investigators propose this study.
The aim of this study is to examine whether automatic control of inspired oxygen and tidal volume together leads to further improvements in maintaining SpO2 profile within the prescribed target range in preterm, ventilated infants.
The objective is to evaluate the efficacy of the automatic oxygen control function with or without VG® (automatic control of ventilator pressure to deliver the set volume) mode of ventilation in keeping oxygen levels in the safe target range (90 to 95%) in ventilated preterm infants requiring oxygen therapy.
This study will be conducted in a tertiary neonatal intensive care unit at the James Cook University Hospital, Middlesbrough, United Kingdom after approval by the Local Research Ethics Committee and the Institutional Review Board.
This study will be completed over 2 consecutive 12-hour periods in randomly assigned sequence of automatic FiO2 control (CLiO2™) with VG® and automatic FiO2 control without VG®.
The Automated FiO2 system CLiO2™ is integral to the Avea® infant ventilator (CareFusion, Yorba Linda, CA) and allows automated FiO2 adjustment aiming to maintain SpO2 within assigned target range using Radical neonatal pulse oximeter (Masimo, Irvine, CA). When first started it adopts the FiO2 previously set by the clinician as the initial 'Baseline FiO2' level. Thereafter, the changes to the FiO2 and their frequency depend on whether SpO2 is below, above or within the target range, the trend in SpO2 and all changes are proportionate to the 'Baseline FiO2' level. FiO2 is reduced in a step wise fashion when SpO2 exceeds the target range. The step decrements in FiO2 result in a gradual reduction in the FiO2. When SpO2 falls below the target range the increments in FiO2 are generally larger and more frequent. These are proportionate to the difference between SpO2 and the target range and the declining or increasing trend in SpO2. The changes in FiO2 generally range between 0.01 and 0.05. Their frequency increases to achieve a faster rate of change of FiO2 and can be as frequent as one per second. The Baseline FiO2 level is gradually adjusted to changes in the infant's needs for FiO2 to keep SpO2 in range. The pulse oximeter default settings are normal sensitivity, 8 second averaging time, 20 second alarm delay, and a tight alarm limit of 90% and 95% SpO2. Masimo neonatal probe (LNOP Neo-L) will be applied to the right wrist whenever possible. In the event of SpO2 signal loss (saturation 'dropouts') the fail-safe mechanism adjusts the backup FiO2 at the median level in the preceding 15 seconds, or to the baseline if higher.
Volume Guarantee ventilation (VG)® is a volume-targeted mode of ventilation aimed at delivering the set tidal volume of gas by automatically adjusting the peak inspiratory pressure (PIP) on a breath-by-breath basis. Theoretically this should minimise variation in tidal volume delivery as lung compliance and the infant's condition changes. This function is achieved by an automated servo-controlled mechanism. The upper PIP limit can be set by the clinician as a safety mechanism. There is lack of data on VG® but it is thought to achieve comparable gas exchange at lower mean PIP levels\[15\].
Volume-Controlled ventilation (VCV) is a type of 'volume targeted' mode. It aims to target be supported the desired tidal volume by delivering a set volume (chosen by the clinician) irrespective of the underlying lung mechanics. The ventilator will generate whatever peak inspiratory pressure is necessary to deliver this volume. There is constant inspiratory flow pattern (a square flow waveform) and peak volume and inspiratory pressure delivery are achieved at the end of inspiration. During 'control period' of 12 hours without VG, infants will using VCV A/C (assist control) as is our current clinical standard.
Both VG® and VCV can be delivered to infants using the ventilators currently in use in our unit, the AVEA® ventilators (Carefusion, Yorba Linda, CA). All devices and equipment used for infants in either arm of the trial will be the same as those currently used on our unit. They will be used in line with Carefusion AVEA® ventilator systems operator's manual, L2786, revision M, July 2011.
Verbal and written information (in the form of the Participant Information Sheet) about the trial will be offered to parents at the earliest opportunity after the infant has been intubated. It will only be offered after all other information about the medical care of their infant and the progress has been discussed with them and only if they wish to receive trial information at that time. Consent will not be obtained before any infant is born.
After the infant has been intubated and ventilated, parents will be approached for participation consent only after relevant information about their infant's medical care and progress has been discussed. Parents will be offered written and verbal information about the trial. Parents giving consent for their baby to participate in the trial will be asked to sign a written consent form. Infants will only be randomised to either Volume Guarantee® or Volume-Controlled ventilation cross-over periods after obtaining written consent from parents.
If the infants' respiratory care is escalated to non-conventional mode of ventilation for clinical reasons, the time spent in the 12 hour cross over would be determined. If the infant has spent at least 50% of the time in a cross-over, this would be considered acceptable and data used for analysis. If the infant has spent less than 50%, then parents will be approached again to revalidate the consent for the study when the infant is ready for conventional ventilation.
When commencing Volume Guarantee® mode a setting of 5ml/kg will be the initial starting setting, with the option of decreasing to 4ml/kg or increasing to 6ml/kg as the clinical condition dictates. This is standard neonatal practice. Nursing allocation will remain at 1:1 (one nurse caring for 1 intensive care infant) as is our standard clinical practice during the study period. Target SpO2 range of 90 to 95% will be applicable to both study periods as is our current clinical practice. All elective / planned procedures will be performed before starting the study. All 'routine patient care and procedures' such as endotracheal tube suction, chest physiotherapy, oral care, change of position, kangaroo care, insertion of lines / cannula and catheters, blood sampling will be recorded during the study period. All babies will receive a loading dose of caffeine citrate (20mg/kg intravenously) followed by 5mg/kg once daily, as per standard practice.
Statistical Analysis:
Intention-to-treat analysis will apply for both 12-hour periods. Statistical analysis will consist of within-patient comparisons with paired t tests for normally distributed data or nonparametric Wilcoxon signed rank tests. Shapiro-Wilk test for normality will be used. Results will be presented as mean ± standard deviation (SD) or median and interquartile range. P values of less than 0.05 will be considered statistically significant. Descriptive statistics will be used for summarising the questionnaire responses. Stata® data analysis and statistical software version 11, Stata Corp LP Texas, USA will be used for all statistics.
Conditions
See the medical conditions and disease areas that this research is targeting or investigating.
Study Design
Understand how the trial is structured, including allocation methods, masking strategies, primary purpose, and other design elements.
RANDOMIZED
CROSSOVER
TREATMENT
NONE
Study Groups
Review each arm or cohort in the study, along with the interventions and objectives associated with them.
automated oxygen control with VG®
Automated oxygen control using closed loop inspired oxygen (CLiO2™) with automated pressure control (Volume Guarantee®).
Mode of ventilation (Volume Guarantee)®
This is a volume-targeted mode of ventilation aimed at delivering the set tidal volume of gas by automatically adjusting the peak inspiratory pressure (PIP) on a breath-by-breath basis. Theoretically this should minimise variation in tidal volume delivery as lung compliance and the infant's condition changes. This function is achieved by an automated servo-controlled mechanism. The upper PIP limit can be set by the clinician as a safety mechanism.
automated oxygen control without VG®
Automated oxygen control using closed loop inspired oxygen (CLiO2™) without automated pressure control (Volume Guarantee®).
Mode of ventilation (Volume control Ventilation)
Volume-Controlled ventilation (VCV) is a type of 'volume targeted' mode. It aims to target be supported the desired tidal volume by delivering a set volume (chosen by the clinician) irrespective of the underlying lung mechanics. The ventilator will generate whatever peak inspiratory pressure is necessary to deliver this volume. There is constant inspiratory flow pattern (a square flow waveform) and peak volume and inspiratory pressure delivery are achieved at the end of inspiration. During the 'control period' of 12 hours without VG, infants will using VCV A/C (assist control) as is our current clinical standard.
Interventions
Learn about the drugs, procedures, or behavioral strategies being tested and how they are applied within this trial.
Mode of ventilation (Volume Guarantee)®
This is a volume-targeted mode of ventilation aimed at delivering the set tidal volume of gas by automatically adjusting the peak inspiratory pressure (PIP) on a breath-by-breath basis. Theoretically this should minimise variation in tidal volume delivery as lung compliance and the infant's condition changes. This function is achieved by an automated servo-controlled mechanism. The upper PIP limit can be set by the clinician as a safety mechanism.
Mode of ventilation (Volume control Ventilation)
Volume-Controlled ventilation (VCV) is a type of 'volume targeted' mode. It aims to target be supported the desired tidal volume by delivering a set volume (chosen by the clinician) irrespective of the underlying lung mechanics. The ventilator will generate whatever peak inspiratory pressure is necessary to deliver this volume. There is constant inspiratory flow pattern (a square flow waveform) and peak volume and inspiratory pressure delivery are achieved at the end of inspiration. During the 'control period' of 12 hours without VG, infants will using VCV A/C (assist control) as is our current clinical standard.
Eligibility Criteria
Check the participation requirements, including inclusion and exclusion rules, age limits, and whether healthy volunteers are accepted.
Inclusion Criteria
* Who are receiving conventional mechanical ventilation through an endotracheal tube.
* On supplemental oxygen at the time of enrolment (Defined as requiring more than 0.21 FiO2 to maintain saturation in the target range).
Exclusion Criteria
* Preterm infants with congenital anomalies
* Infants on a non-conventional mode of ventilation Infants on inhaled Nitric Oxide
23 Weeks
36 Weeks
ALL
No
Sponsors
Meet the organizations funding or collaborating on the study and learn about their roles.
South Tees Hospitals NHS Foundation Trust
OTHER
Responsible Party
Identify the individual or organization who holds primary responsibility for the study information submitted to regulators.
Principal Investigators
Learn about the lead researchers overseeing the trial and their institutional affiliations.
Vrinda Nair, MBBS,FRCPCH
Role: PRINCIPAL_INVESTIGATOR
South Tees NHS Trust
Locations
Explore where the study is taking place and check the recruitment status at each participating site.
James Cook University Hospital
Middlesbrough, Stockton ON TEES, United Kingdom
Countries
Review the countries where the study has at least one active or historical site.
References
Explore related publications, articles, or registry entries linked to this study.
Stoll BJ, Hansen NI, Bell EF, Shankaran S, Laptook AR, Walsh MC, Hale EC, Newman NS, Schibler K, Carlo WA, Kennedy KA, Poindexter BB, Finer NN, Ehrenkranz RA, Duara S, Sanchez PJ, O'Shea TM, Goldberg RN, Van Meurs KP, Faix RG, Phelps DL, Frantz ID 3rd, Watterberg KL, Saha S, Das A, Higgins RD; Eunice Kennedy Shriver National Institute of Child Health and Human Development Neonatal Research Network. Neonatal outcomes of extremely preterm infants from the NICHD Neonatal Research Network. Pediatrics. 2010 Sep;126(3):443-56. doi: 10.1542/peds.2009-2959. Epub 2010 Aug 23.
SUPPORT Study Group of the Eunice Kennedy Shriver NICHD Neonatal Research Network; Carlo WA, Finer NN, Walsh MC, Rich W, Gantz MG, Laptook AR, Yoder BA, Faix RG, Das A, Poole WK, Schibler K, Newman NS, Ambalavanan N, Frantz ID 3rd, Piazza AJ, Sanchez PJ, Morris BH, Laroia N, Phelps DL, Poindexter BB, Cotten CM, Van Meurs KP, Duara S, Narendran V, Sood BG, O'Shea TM, Bell EF, Ehrenkranz RA, Watterberg KL, Higgins RD. Target ranges of oxygen saturation in extremely preterm infants. N Engl J Med. 2010 May 27;362(21):1959-69. doi: 10.1056/NEJMoa0911781. Epub 2010 May 16.
Stenson B, Brocklehurst P, Tarnow-Mordi W; U.K. BOOST II trial; Australian BOOST II trial; New Zealand BOOST II trial. Increased 36-week survival with high oxygen saturation target in extremely preterm infants. N Engl J Med. 2011 Apr 28;364(17):1680-2. doi: 10.1056/NEJMc1101319. No abstract available.
Laptook AR, Salhab W, Allen J, Saha S, Walsh M. Pulse oximetry in very low birth weight infants: can oxygen saturation be maintained in the desired range? J Perinatol. 2006 Jun;26(6):337-41. doi: 10.1038/sj.jp.7211500.
Hagadorn JI, Furey AM, Nghiem TH, Schmid CH, Phelps DL, Pillers DA, Cole CH; AVIOx Study Group. Achieved versus intended pulse oximeter saturation in infants born less than 28 weeks' gestation: the AVIOx study. Pediatrics. 2006 Oct;118(4):1574-82. doi: 10.1542/peds.2005-0413.
Claure N, Bancalari E. Closed-loop control of inspired oxygen in premature infants. Semin Fetal Neonatal Med. 2015 Jun;20(3):198-204. doi: 10.1016/j.siny.2015.02.003. Epub 2015 Mar 12.
Claure N, Gerhardt T, Everett R, Musante G, Herrera C, Bancalari E. Closed-loop controlled inspired oxygen concentration for mechanically ventilated very low birth weight infants with frequent episodes of hypoxemia. Pediatrics. 2001 May;107(5):1120-4. doi: 10.1542/peds.107.5.1120.
Claure N, D'Ugard C, Bancalari E. Automated adjustment of inspired oxygen in preterm infants with frequent fluctuations in oxygenation: a pilot clinical trial. J Pediatr. 2009 Nov;155(5):640-5.e1-2. doi: 10.1016/j.jpeds.2009.04.057.
Claure N, Bancalari E, D'Ugard C, Nelin L, Stein M, Ramanathan R, Hernandez R, Donn SM, Becker M, Bachman T. Multicenter crossover study of automated control of inspired oxygen in ventilated preterm infants. Pediatrics. 2011 Jan;127(1):e76-83. doi: 10.1542/peds.2010-0939. Epub 2010 Dec 27.
Waitz M, Schmid MB, Fuchs H, Mendler MR, Dreyhaupt J, Hummler HD. Effects of automated adjustment of the inspired oxygen on fluctuations of arterial and regional cerebral tissue oxygenation in preterm infants with frequent desaturations. J Pediatr. 2015 Feb;166(2):240-4.e1. doi: 10.1016/j.jpeds.2014.10.007. Epub 2014 Nov 18.
Lal M, Tin W, Sinha S. Automated control of inspired oxygen in ventilated preterm infants: crossover physiological study. Acta Paediatr. 2015 Nov;104(11):1084-9. doi: 10.1111/apa.13137.
Mitra S, Singh B, El-Naggar W, McMillan DD. Automated versus manual control of inspired oxygen to target oxygen saturation in preterm infants: a systematic review and meta-analysis. J Perinatol. 2018 Apr;38(4):351-360. doi: 10.1038/s41372-017-0037-z. Epub 2018 Jan 2.
Johnston ED, Boyle B, Juszczak E, King A, Brocklehurst P, Stenson BJ. Oxygen targeting in preterm infants using the Masimo SET Radical pulse oximeter. Arch Dis Child Fetal Neonatal Ed. 2011 Nov;96(6):F429-33. doi: 10.1136/adc.2010.206011. Epub 2011 Mar 6.
van Kaam AH, Hummler HD, Wilinska M, Swietlinski J, Lal MK, te Pas AB, Lista G, Gupta S, Fajardo CA, Onland W, Waitz M, Warakomska M, Cavigioli F, Bancalari E, Claure N, Bachman TE. Automated versus Manual Oxygen Control with Different Saturation Targets and Modes of Respiratory Support in Preterm Infants. J Pediatr. 2015 Sep;167(3):545-50.e1-2. doi: 10.1016/j.jpeds.2015.06.012. Epub 2015 Jul 2.
Jain D, Claure N, D'Ugard C, Bello J, Bancalari E. Volume Guarantee Ventilation: Effect on Preterm Infants with Frequent Hypoxemia Episodes. Neonatology. 2016;110(2):129-34. doi: 10.1159/000444844. Epub 2016 Apr 19.
Nair V, Lal MK, Gillone J, Kannan Loganathan P, Bachman TE. Comparison of volume guarantee and volume-controlled ventilation both using closed loop inspired oxygen in preterm infants: a randomised crossover study (CLIO-VG study). Arch Dis Child Fetal Neonatal Ed. 2022 Mar;107(2):161-165. doi: 10.1136/archdischild-2021-321712. Epub 2021 Jul 7.