Measuring Oxygenation of Newborn Infants in Targeted Oxygen Ranges
NCT ID: NCT03360292
Last Updated: 2022-03-28
Study Results
The study team has not published outcome measurements, participant flow, or safety data for this trial yet. Check back later for updates.
Basic Information
Get a concise snapshot of the trial, including recruitment status, study phase, enrollment targets, and key timeline milestones.
COMPLETED
NA
20 participants
INTERVENTIONAL
2020-01-18
2022-02-17
Brief Summary
Review the sponsor-provided synopsis that highlights what the study is about and why it is being conducted.
It is still unclear exactly what levels of oxygen premature babies need - both too little or too much oxygen in the first weeks after birth may be harmful. Previous studies used saturation monitoring (SpO2), where a small probe shines light through the skin and calculates how much oxygen is carried in the blood. These studies demonstrated using an SpO2 range of 91-95% rather than 85-89% was associated with more babies surviving and fewer babies suffering from a bowel condition called necrotising enterocolitis (NEC). However, targeting oxygen higher increased the number of infants who needed treatment for an eye condition called retinopathy of prematurity (ROP).
It is possible an SpO2 range higher than 91-95% would be associated with even better survival. It is also possible that a higher range might not improve survival but could increase the need for ROP treatment.
Infants born at less than 29 weeks gestation, greater than 48 hours of age and receiving supplementary oxygen would be eligible for inclusion. The study is at the Royal Infirmary of Edinburgh. Total study time is 12 hours for each infant (6 hours at the standard 90-95% range used in our unit, and 6 hours at 92-97%). It is a crossover study with infants acting as their own controls.
Based on previous research the investigators are confident these oxygen levels will not be dangerously high. To provide an additional measure of oxygen the investigators will also use a transcutaneous monitor for the 12 hour study period, which fastens gently to the skin and measures oxygen and carbon dioxide levels on the skin surface.
Related Clinical Trials
Explore similar clinical trials based on study characteristics and research focus.
Initial Oxygen Concentration at Birth in Late-Preterm Infants
NCT07315594
Baby Oxygen Saturation Study
NCT03092661
Appropriate Oxygen Levels for Extremely Preterm Infants: a Prospective Meta-analysis
NCT01124331
Comparison of Different Oxygen Delivery Strategies During Resuscitation of Babies
NCT00356902
Effects of Targeting Lower Arterial Oxygen Saturations on the Development of Control of Breathing in Very Preterm Infants
NCT00573053
Detailed Description
Dive into the extended narrative that explains the scientific background, objectives, and procedures in greater depth.
A complete list of all monitoring that will be carried out is shown below:
1. SpO2 monitoring
2. TcPO2 monitoring
3. Heart rate monitoring (used to validate SpO2 readings as described below)
4. Arterial gas sampling (only if conducted by the direct care team as part of the routine care of the infant will these be recorded. No extra blood samples will be taken as part of the study)
Each infant will be monitored simultaneously with an SpO2 monitor and TcPo2 monitor, with data recording starting from the time the transcutaneous monitor finishes calibrating. SpO2 readings will be downloaded directly from the multiparameter patient monitor. SpO2 will be measured using a Siemens Infinity SC7000 multiparameter monitor. This monitor uses Siemens' Oxisure pulse oximetry technology and Nellcor Oximax saturation probes and incorporates ECG to reduce motion artefact. To reduce the influence of artefact further, data from an infants chest leads (recording heart rate) will also be downloaded. If there is a greater than 10 beats per minute difference between heart rate measured from the pulse oximeter and heart rate measured from the chest leads, SpO2 for that time point will be disregarded.
TcPO2 will be measured using a SenTec Digital Monitoring System with OxiVent sensor. TcPO2 is calculated by dynamic fluorescence quenching which measures oxygen molecules present in the vicinity of a fluorescent dye incorporated within the sensor surface. The sensor is operated at a constant temperature of 43 degrees Celsius. Control of sensor temperature and application duration are designed to meet all applicable standards and this monitoring device is used routinely in many neonatal units, with transcutaneous monitoring part of the monitoring equipment we use in selected infants in our unit and being transported by our local neonatal transport team. Temperature is supervised by two independent circuits, as well as by the monitor firmware.
Transcutaneous data will be transferred contemporaneously to a bedside PC via the proprietary software V-STATS (with V-CareNeT) version 4.01. We will ensure the time on the monitor is synchronised with the time displayed on the electronic patient record system recording SpO2 and heart rate. V-STATS software can identify any spurious spikes in TcPO2 caused by air bubbles and these identified segments of data will be discarded. Artefact has not significantly affected readings during the routine use of this monitor previously on our neonatal unit and with our neonatal transport team. The site of the transcutaneous probe will be rotated on each infant every 2 hours.
SpO2, TcPO2 and heart rate data will be recorded every second. The time of any arterial oxygen samples taken routinely during the study will be recorded from the unit Radiometer ABL800 FLEX blood gas analyser.
Conditions
See the medical conditions and disease areas that this research is targeting or investigating.
Study Design
Understand how the trial is structured, including allocation methods, masking strategies, primary purpose, and other design elements.
RANDOMIZED
CROSSOVER
TREATMENT
NONE
Study Groups
Review each arm or cohort in the study, along with the interventions and objectives associated with them.
Higher target range
Infants will be targeted to 92-97% oxygen saturation
Higher target range
Intervention is using a higher oxygen saturation target range than in routine practice
Standard target range
Infants will be targeted to 90-95% oxygen saturation, which is the range used as routine in the Neonatal Unit involved in the study
No interventions assigned to this group
Interventions
Learn about the drugs, procedures, or behavioral strategies being tested and how they are applied within this trial.
Higher target range
Intervention is using a higher oxygen saturation target range than in routine practice
Other Intervention Names
Discover alternative or legacy names that may be used to describe the listed interventions across different sources.
Eligibility Criteria
Check the participation requirements, including inclusion and exclusion rules, age limits, and whether healthy volunteers are accepted.
Inclusion Criteria
* Infants greater than 48 hours of age
* Infants who are receiving supplementary oxygen
Exclusion Criteria
48 Hours
1 Month
ALL
No
Sponsors
Meet the organizations funding or collaborating on the study and learn about their roles.
NHS Lothian
OTHER_GOV
University of Edinburgh
OTHER
Responsible Party
Identify the individual or organization who holds primary responsibility for the study information submitted to regulators.
Locations
Explore where the study is taking place and check the recruitment status at each participating site.
Neonatal Unit - Royal Infirmary of Edinburgh
Edinburgh, Lothian, United Kingdom
Countries
Review the countries where the study has at least one active or historical site.
References
Explore related publications, articles, or registry entries linked to this study.
Christie FG, Kelly R, Boardman JP, Stenson BJ. Measuring Oxygenation in Newborn Infants with Targeted Oxygen Ranges (MONITOR): a randomised crossover pilot study. Arch Dis Child Fetal Neonatal Ed. 2023 Nov;108(6):638-642. doi: 10.1136/archdischild-2022-324833. Epub 2023 May 4.
Provided Documents
Download supplemental materials such as informed consent forms, study protocols, or participant manuals.
Document Type: Study Protocol and Statistical Analysis Plan
Document Type: Informed Consent Form
Other Identifiers
Review additional registry numbers or institutional identifiers associated with this trial.
194632
Identifier Type: REGISTRY
Identifier Source: secondary_id
AC17098
Identifier Type: -
Identifier Source: org_study_id
More Related Trials
Additional clinical trials that may be relevant based on similarity analysis.