Iliac Branch Device Movement During Cardiac Cycle (IBD-dynamics)

NCT ID: NCT03762525

Last Updated: 2021-02-12

Study Results

Results pending

The study team has not published outcome measurements, participant flow, or safety data for this trial yet. Check back later for updates.

Basic Information

Get a concise snapshot of the trial, including recruitment status, study phase, enrollment targets, and key timeline milestones.

Recruitment Status

COMPLETED

Clinical Phase

NA

Total Enrollment

45 participants

Study Classification

INTERVENTIONAL

Study Start Date

2016-10-05

Study Completion Date

2020-12-31

Brief Summary

Review the sponsor-provided synopsis that highlights what the study is about and why it is being conducted.

The incidence of isolated common iliac artery (CIA) aneurysms is low, but in combination with an abdominal aortic aneurysm (AAA) they are found in approximately 20-40% of cases. Basically, two different endovascular strategies can be applied to treat a CIA aneurysm with, including 1. the coverage and 2. the preservation of blood flow to the internal iliac artery (IIA). Coil and coverage of the IIA is related to ischemic complications, including buttock claudication, erectile dysfunction and the more severe spinal and colonic ischemia. Iliac branched devices (IBD) have been developed to exclude CIA aneurysms preserving the IIA and currently three alternatives are on the market. Clinical results of these devices are promising but loss of patency is not uncommon. The major difference between the two devices is the IIA component. The Cook IBD uses a -non-dedicated IIA component, while in the GORE® EXCLUDER® Iliac Branch Endoprosthesis (Gore IBE device) a dedicated self expanding stent is used. Stresses and forces exerted onto the endograft by aortic pulsatility may have an effect on the durability and functioning of the endograft. Intermittent hinchpoints could also have an effect on stent integrity and stenosis. By evaluating endograft movement during the cardiac cycle (ECG-gated CTA) it is possible to assess the stress and force exerted onto the endograft. This might help gain insight into mechanisms underlying potential endograft failure, and aid procedural planning and the development of future devices with long-term durability.

The choice for device is not part of this study.

Detailed Description

Dive into the extended narrative that explains the scientific background, objectives, and procedures in greater depth.

Objectives:To compare the mobility of the hypogastic artery during the cardiac cycle before and six weeks after implantation of the Gore IBE device in conjunction with its dedicated self expandable Internal Iliac component (Sub-study A);and to quantitatively characterize the displacement of stents with regard to the main body and native IIA during the cardiac cycle on an implanted iliac branched endograft in conjunction with a non-dedicated IIA component (Cook IBD with Advanta V12 or Fluency) with those in conjunction with a dedicated self expandable Internal Iliac component (Gore IBE device). (Sub-study B) Study design: Sub-study A \& B: Multicenter observational case studies Study population: Sub-study A: 15 prospectively included patients and sub-study B: 15 patients in each group that have been treated in the period October 2006 - July 2016.

Conditions

See the medical conditions and disease areas that this research is targeting or investigating.

Iliac Aneurysm Angiography AAA

Study Design

Understand how the trial is structured, including allocation methods, masking strategies, primary purpose, and other design elements.

Allocation Method

NON_RANDOMIZED

Intervention Model

SINGLE_GROUP

This study is designed as a multicenter prospective case series.

1. To prospectively enroll 15 patients that are scheduled for endovascular aneurysm repair using the Gore IBE device in conjunction with its dedicated self expanding Internal Iliac component.
2. Tocompare 15 patients that have been treated in the period October 2006- July 2016 with the Cook IBD with a non-dedicated IIA component (Advanta-V12 or Fluency) and 15 matched patients treated with Gore IBE device.
Primary Study Purpose

OTHER

Blinding Strategy

NONE

The choice for the device is not part of this study and will be made by the doctor in consultation with the patient and the patients anatomy.

Study Groups

Review each arm or cohort in the study, along with the interventions and objectives associated with them.

ECG gated CTA pre and post operative at Gore IBE

To prospectively enroll 15 patients that are scheduled for endovascular aneurysm repair using the Gore IBE device in conjunction with its dedicated self expanding Internal Iliac component. Each patient will have an ECG gated CTA scan before the operation and 6-8 weeks after operation, in stead of a regular CT scan.

Group Type OTHER

ECG gated CTA

Intervention Type RADIATION

Routine care consists of a preoperative and several postoperative CTA scans. In A. The preoperative and first postoperative CTA will be replaced by ECG-gated CTA imaging and in B. the scheduled imaging will be replaced by an ECG-gated CTA.

General information: The protocol is based on the ECG gated cardiac protocol using abdominal parameter settings.

ECG gated CTA post operative at Gore IBE and Cook IBD

To compare 15 patients that have been treated in the period October 2006- July 2016 with the Cook IBD with a non-dedicated IIA component (Advanta-V12 or Fluency) and 15 matched patients treated with Gore IBE device. Each patient will have an ECG gated CTA after the operation, at the first doctor's appointment, in stead of a regular CT scan.

Group Type OTHER

ECG gated CTA

Intervention Type RADIATION

Routine care consists of a preoperative and several postoperative CTA scans. In A. The preoperative and first postoperative CTA will be replaced by ECG-gated CTA imaging and in B. the scheduled imaging will be replaced by an ECG-gated CTA.

General information: The protocol is based on the ECG gated cardiac protocol using abdominal parameter settings.

Interventions

Learn about the drugs, procedures, or behavioral strategies being tested and how they are applied within this trial.

ECG gated CTA

Routine care consists of a preoperative and several postoperative CTA scans. In A. The preoperative and first postoperative CTA will be replaced by ECG-gated CTA imaging and in B. the scheduled imaging will be replaced by an ECG-gated CTA.

General information: The protocol is based on the ECG gated cardiac protocol using abdominal parameter settings.

Intervention Type RADIATION

Eligibility Criteria

Check the participation requirements, including inclusion and exclusion rules, age limits, and whether healthy volunteers are accepted.

Inclusion Criteria

* Sub-study A. scheduled endovascular aneurysm repair using the Gore IBE device.
* Sub-study B. Patients that have been treated with an iliac branched device in the past in conjunction with either a dedicated IIA component (Gore IBE device) or non-dedicated IIA component (Cook IBD) and who are scheduled for follow-up imaging within the period July 2016-January 2017.
Eligible Sex

ALL

Accepts Healthy Volunteers

No

Sponsors

Meet the organizations funding or collaborating on the study and learn about their roles.

Rijnstate Hospital

OTHER

Sponsor Role lead

Responsible Party

Identify the individual or organization who holds primary responsibility for the study information submitted to regulators.

Michel Reijnen

Prof. Dr., Principal Investigator

Responsibility Role PRINCIPAL_INVESTIGATOR

Principal Investigators

Learn about the lead researchers overseeing the trial and their institutional affiliations.

Michel Reijnen, MD, PhD

Role: PRINCIPAL_INVESTIGATOR

Principal Investigator

Locations

Explore where the study is taking place and check the recruitment status at each participating site.

Rijnstate Hospital

Arnhem, , Netherlands

Site Status

Universitair Medisch Centrum Groningen

Groningen, , Netherlands

Site Status

Elisabeth Tweesteden ziekenhuis

Tilburg, , Netherlands

Site Status

Countries

Review the countries where the study has at least one active or historical site.

Netherlands

Other Identifiers

Review additional registry numbers or institutional identifiers associated with this trial.

IBD-dynamics

Identifier Type: -

Identifier Source: org_study_id

More Related Trials

Additional clinical trials that may be relevant based on similarity analysis.