Active Limb Orthosis for Home-Use Stroke Hemiparetic Gait Rehabilitation
NCT ID: NCT03649217
Last Updated: 2022-02-03
Study Results
Outcome measurements, participant flow, baseline characteristics, and adverse events have been published for this study.
View full resultsBasic Information
Get a concise snapshot of the trial, including recruitment status, study phase, enrollment targets, and key timeline milestones.
COMPLETED
NA
23 participants
INTERVENTIONAL
2018-07-09
2019-12-09
Brief Summary
Review the sponsor-provided synopsis that highlights what the study is about and why it is being conducted.
Related Clinical Trials
Explore similar clinical trials based on study characteristics and research focus.
iStride(TM) Device Used for Stroke Rehabilitation
NCT02185404
Treatment of Hemiparetic Gait Impairments Using Telehealth With the Moterum iStride Solution™
NCT04434313
Ankle Robotics After Stroke
NCT04594837
Walking Therapy In Hemiparetic Stroke Patients Using Robotic-Assisted Treadmill Training
NCT00075283
Stimulation Combined With Powered Motorized Orthoses for Walking After Stroke
NCT04116671
Detailed Description
Dive into the extended narrative that explains the scientific background, objectives, and procedures in greater depth.
In this study, we will test the efficacy of the iStride device on individuals with stroke in the clinic and within their own home. Efficacy will be evaluated based on the change in gait coordination and also based on subjects' self-reported comfort on the device. We predict that the iStride device will result in changes to interlimb coordination of gait and prove to be a safe and effective device to be used in ones' home.
The asymmetric nature of hemiparetic gait can have a large impact on functional walking ability. For example, swing phase asymmetry is a significant predictor of hemiparetic walking performance because it strongly correlates with stages of motor recovery, walking speed, and falls. Another measure of temporal asymmetry - double support duration - is similarly correlated with walking speed. In addition, spatial (e.g. step length) asymmetry is associated with decreased propulsive force on the paretic leg, which limits forward motion of the body and reduces gait efficiency. The importance of gait efficiency should not be understated - the elevated energy demands of hemiparetic gait combined with physical deconditioning post-stroke can greatly limit performance of activities of daily living, contributing to poor cardiovascular fitness and metabolic syndrome. In turn, this can increase the risks of a second stroke or cardiovascular event and is associated with increased morbidity and mortality rates. Therefore, improving gait symmetry should be an important goal for therapy, to not only improve functional mobility and reduce injury, but also to enhance general health and well-being post-stroke.
Practicing walking on a split-belt treadmill can correct abnormal interlimb coordination of gait in individuals with hemiparesis following stroke or other central nervous system lesions. Asymmetric gait can manifest as a spatial asymmetry, in which steps taken on one side are longer than those on the other. It can also manifest as a temporal asymmetry, where the timing is uneven on the paretic and non-paretic sides. Temporal asymmetries are often measured as differences in the duration of double support periods, which are the amount of time both feet are simultaneously contacting the ground and are measured separately for the paretic and non-paretic sides. The iStride device is designed to cause changes in both spatial and temporal gait symmetry. We predict that the iStride device would cause the steps on the side with the iStride device to be larger since individuals would compensate for the backward rolling motion by placing their foot farther forward in stance, thus increasing the distance between the two feet. Similarly, since the stride is longer, it may also shorten the duration of stance relative to the other side. With shortened stance duration, the amount of time spent in double-support at the end of stance would likely decrease as well.
Although the original idea of the iStride device is derived from the motion of the split-belt-treadmill, there are distinct differences between walking on the device and walking on a split-belt treadmill with asymmetric belt velocities. While the body's velocity relative to ground is zero on a split-belt treadmill, the relative velocity of the iStride device is non-zero and forward. The device forces the wearer's foot forward or backward whereas the treadmill moves both feet backward, but at different speeds. For both the split-belt treadmill and the iStride device, the relative velocity between both feet is similar and the backward-moving iStride device takes the place of the faster tread.
We hypothesize that training over ground will lead to a change in the interlimb coordination in individuals with asymmetric gait and allow individuals to develop a more persistent symmetric gait. There are several differences between training on ground and a treadmill, such as visual flow and vestibular information signaling forward movement that likely limit the expression of learning in the over-ground context when trained on a treadmill. Visual cues appear to be particularly important for context awareness. Visual cues, coupled with prior experience, are so powerful that predictive postural responses cause an individual to stumble when stepping onto an escalator that is not moving. The body has learned an internal model that expects an acceleration when stepping onto an escalator, but when that acceleration does not occur, the person stumbles. A study of split-belt walking showed that transfer to over-ground walking is enhanced when subjects are blindfolded during training on the treadmill and tested over ground. Since blindfolding eliminates visual cues about the environment, this also suggests that vision is a key factor in determining the context-dependence of learning. Since it is not realistic to blindfold stroke patients during gait training, we designed the iStride device so that training could occur during over-ground walking, thus visual cues during training and later walking over ground would be the same.
Data from control subjects using an earlier version of the iStride device (referred to as GEMS at the time) has been published and a video of this previous version can be found at http://reedlab.eng.usf.edu/publications/handzic2011GEMS.mp4. In this study, we found that this earlier version of the device was capable of changing step length as predicted, however the previous design was too heavy and too tall to be considered practical for testing in stroke populations. The current version of the iStride device produces similar motion to the previous version, but it weighs less (under 1 kg) and is shorter (\~4.4 cm). We will test the efficacy of wearing the current iStride device on gait coordination during walking over ground on individuals with stroke in the clinic and within their own home. All walking will be performed while subjects are closely guarded by an experienced physical therapist to prevent falling. The effects of the iStride device on gait coordination will be compared to those induced on a split-belt treadmill.
The proposed project represents one of the first attempts to build a device that corrects walking symmetry while walking over ground. Not only would this allow people to experience gait corrections while performing normal movements, but the simplicity and relative low cost of these devices would also open up potential opportunities to train at home (for high-functioning individuals with supervision) and in clinics where a split-belt treadmill is not available. The studies outlined here will establish whether the iStride device is capable of changing interlimb coordination of gait, and whether individuals with stroke can use these devices for rehabilitation purposes. This work will thus build the foundation for future training studies examining the effectiveness of long-term use of the iStride device for improving symmetric walking patterns.
The question that this study targets is the modification of human walking patterns for use in stroke rehabilitation. It is our ultimate objective to show that the iStride device can change a person's temporal and spatial gait asymmetry into a symmetric gait. We have demonstrated this in a clinic setting, and now we will test the device within the participants own home. Our points of reference are results obtained by previous studies with split-belt treadmills. We are also interested in how altering the interface between a foot and the ground influences the adaptation to new walking patterns.
Conditions
See the medical conditions and disease areas that this research is targeting or investigating.
Study Design
Understand how the trial is structured, including allocation methods, masking strategies, primary purpose, and other design elements.
NA
SINGLE_GROUP
TREATMENT
NONE
Study Groups
Review each arm or cohort in the study, along with the interventions and objectives associated with them.
wearing the iStride device
The training will consist of four weeks of training with three training sessions performed each week. The training sessions will consist of up to thirty minutes of training with the iStride on, with breaks between walking sessions and as needed if the subject requests an additional break. Subjects will place the device on their foot in which they have the shortest step length, as measured during the pre-training gait analysis. This is typically the healthy side foot. There will also be several follow up visits following the final testing session.
wearing the iStride device
The device mimics the actions of the split-belt treadmill, but can be used during over-ground walking and in one's own home, thus enabling long-term training. This device does not require any external power and is completely passive; all necessary forces are redirected from the natural forces present during walking since it utilizes the wearer's weight to generate its movements. This research aims to test the iStride on individuals with stroke in their own home in order to determine if the related effects that we saw in the clinic, can also benefit patients at home.
Interventions
Learn about the drugs, procedures, or behavioral strategies being tested and how they are applied within this trial.
wearing the iStride device
The device mimics the actions of the split-belt treadmill, but can be used during over-ground walking and in one's own home, thus enabling long-term training. This device does not require any external power and is completely passive; all necessary forces are redirected from the natural forces present during walking since it utilizes the wearer's weight to generate its movements. This research aims to test the iStride on individuals with stroke in their own home in order to determine if the related effects that we saw in the clinic, can also benefit patients at home.
Eligibility Criteria
Check the participation requirements, including inclusion and exclusion rules, age limits, and whether healthy volunteers are accepted.
Inclusion Criteria
* one or more cerebral strokes, but all strokes on same side
* a stroke at least 6 months prior to enrollment
* Gait asymmetry, but able to walk independently with or without a cane
* Not currently receiving physical therapy
* no evidence of severe cognitive impairment that would interfere with understanding the instructions
* no evidence of one-sided neglect, affecting ambulation
* At least 25 feet of walking space in home (does not need to be a straight line)
* Weight does not exceed 250 lbs
Exclusion Criteria
* metal implants (stents, clips, pacemaker)
* pregnancy
* History of a neurological disorder other than stroke ( Parkinson's, MS)
* Chronic Obstructive Pulmonary Disease
* Uncontrolled blood pressure
* Head injury in the past 90 days
* A myocardial infarction within the last 180 days
* Cannot rely on a rolling walker for ambulation
21 Years
80 Years
ALL
No
Sponsors
Meet the organizations funding or collaborating on the study and learn about their roles.
Moterum Technologies, Inc.
INDUSTRY
University of South Florida
OTHER
Responsible Party
Identify the individual or organization who holds primary responsibility for the study information submitted to regulators.
Principal Investigators
Learn about the lead researchers overseeing the trial and their institutional affiliations.
Lauren Rashford, PT
Role: STUDY_DIRECTOR
Moterum Technologies, LLC
Locations
Explore where the study is taking place and check the recruitment status at each participating site.
University of South Florida
Tampa, Florida, United States
homes throughout Charlotte, NC
Charlotte, North Carolina, United States
homes throughout Memphis, TN
Memphis, Tennessee, United States
homes throughout Burlington, VT
Burlington, Vermont, United States
Countries
Review the countries where the study has at least one active or historical site.
References
Explore related publications, articles, or registry entries linked to this study.
Handzic I, Barno EM, Vasudevan EV, Reed KB. Design and Pilot Study of a Gait Enhancing Mobile Shoe. Paladyn. 2011 Dec 1;2(4):10.2478/s13230-012-0010-7. doi: 10.2478/s13230-012-0010-7.
Handzic I, Vasudevan E, Reed KB. Developing a Gait Enhancing Mobile Shoe to Alter Over-Ground Walking Coordination. IEEE Int Conf Robot Autom. 2012 May;2012:4124-4129. doi: 10.1109/ICRA.2012.6225346.
Kim S, Handzic I, Huizenga D, Edgeworth R, Lozinski M, Ramakrishnan T, & Reed KB,
Handzic I, Reed KB. Comparison of the passive dynamics of walking on ground, tied-belt and split-belt treadmills, and via the Gait Enhancing Mobile Shoe (GEMS). IEEE Int Conf Rehabil Robot. 2013 Jun;2013:6650509. doi: 10.1109/ICORR.2013.6650509.
Kim SH, Huizenga DE, Handzic I, Ditwiler RE, Lazinski M, Ramakrishnan T, Bozeman A, Rose DZ, Reed KB. Relearning functional and symmetric walking after stroke using a wearable device: a feasibility study. J Neuroeng Rehabil. 2019 Aug 28;16(1):106. doi: 10.1186/s12984-019-0569-x.
Darcy B, Rashford L, Tsai NT, Huizenga D, Reed KB, Bamberg SJM. One-year retention of gait speed improvement in stroke survivors after treatment with a wearable home-use gait device. Front Neurol. 2024 Jan 11;14:1089083. doi: 10.3389/fneur.2023.1089083. eCollection 2023.
Provided Documents
Download supplemental materials such as informed consent forms, study protocols, or participant manuals.
Document Type: Study Protocol and Statistical Analysis Plan
Related Links
Access external resources that provide additional context or updates about the study.
Additional information on a related stroke rehabilitation shoe.
Commercial information about the iStride(TM) Device
Other Identifiers
Review additional registry numbers or institutional identifiers associated with this trial.
Moterum-iStride
Identifier Type: -
Identifier Source: org_study_id
More Related Trials
Additional clinical trials that may be relevant based on similarity analysis.