Laser Used in the Treatment of Hypomineralized Occlusal Lesions in Teeth Enamel Affected by MIH
NCT ID: NCT03614819
Last Updated: 2023-05-12
Study Results
The study team has not published outcome measurements, participant flow, or safety data for this trial yet. Check back later for updates.
Basic Information
Get a concise snapshot of the trial, including recruitment status, study phase, enrollment targets, and key timeline milestones.
COMPLETED
NA
122 participants
INTERVENTIONAL
2018-08-30
2022-08-30
Brief Summary
Review the sponsor-provided synopsis that highlights what the study is about and why it is being conducted.
Related Clinical Trials
Explore similar clinical trials based on study characteristics and research focus.
HYPERSENSITIVITY IN MOLAR INCISOR HYPOMINERALISATION USING LOW LEVEL LASER IN CHILDREN
NCT06154733
Interventions to Control Hypersensitivity Pain in Teeth With Insisive Molar Hypomineralization
NCT06426108
Effect of Low-intensity Laser and Photodynamic Therapy on Infected Dentin of Permanent Teeth With MIH
NCT03826810
Photobiomodulation and Glass Ionomer Sealant as Complementary Treatment for Hypersensitivity in Molars With MIH
NCT05370417
Photobiomodulation and New Restorative Material for Teeth With MIH on Control of Hypersensitivity and Longevity
NCT06538142
Detailed Description
Dive into the extended narrative that explains the scientific background, objectives, and procedures in greater depth.
Conditions
See the medical conditions and disease areas that this research is targeting or investigating.
Study Design
Understand how the trial is structured, including allocation methods, masking strategies, primary purpose, and other design elements.
RANDOMIZED
PARALLEL
Glass Ionomer Sealing Group Prophylaxis of the selected region for the study, followed by relative insulation with cotton rollers of the tooth in question, application of acid polyacrylic for 15 seconds throughout the surface, light drying with cotton ball, insertion of the high viscosity glass ionomer (Equia Forte in capsule - GC) through a specific applicator, after loss of the gloss of the digital pressure material with Vaseline for due drainage and surface protection of the material.
PREVENTION
NONE
Study Groups
Review each arm or cohort in the study, along with the interventions and objectives associated with them.
Diode laser group
Prophylaxis of the selected region for the study with Robson brush and prophylactic paste, washing and drying, followed by application of diode laser (Sirolaser, Sirona Dental Systems GmbH, Bensheim, Germany) with wavelength of 970 nm +/- 10 nm, maximum power of 7 W CW, 1mW guide beam and 320μm optical fiber. Irradiation will be performed on the entire occlusal surface in contact mode, with power of 0.7 W (energy of 70 mJ) and frequency of 10 Hz for 30 seconds, having an energy density of 222.82 J / cm2. The FieldMaxII-TOP power meter (Coherent, Inc, USA) will be used prior to and after the applications. The laser will be applied in a sweeping motion throughout the affected surface, the fiber being maintained positioned perpendicular to the occlusal surface throughout the movement. The irradiation time will be standardized in 30 seconds.
Diode laser group
Prophylaxis of the selected region for the study with Robson brush and prophylactic paste, washing and drying, followed by application of diode laser (Sirolaser, Sirona Dental Systems GmbH, Bensheim, Germany) with wavelength of 970 nm +/- 10 nm, maximum power of 7 W CW, 1mW guide beam and 320μm optical fiber. Irradiation will be performed on the entire occlusal surface in contact mode, with power of 0.7 W (energy of 70 mJ) and frequency of 10 Hz for 30 seconds, having an energy density of 222.82 J / cm2. The FieldMaxII-TOP power meter (Coherent, Inc, USA) will be used prior to and after the applications. The laser will be applied in a sweeping motion throughout the affected surface, the fiber being maintained positioned perpendicular to the occlusal surface throughout the movement. The irradiation time will be standardized in 30 seconds.
Glass Ionomer Sealing Group
Prophylaxis of the selected region for the study with Robson brush and prophylactic paste, washing and drying with cotton balls, followed by relative insulation with cotton rollers of the tooth in question, application of acid polyacrylic for 15 seconds throughout the surface, light drying with cotton ball, insertion of the high viscosity glass ionomer (Equia Forte in capsule - GC) through a specific applicator, after loss of the gloss of the digital pressure material with Vaseline for due drainage and surface protection of the material, removal of the excess, checking the occlusion with carbon paper, occlusal adjustments if necessary, superficial protection with petroleum jelly.
Glass Ionomer Sealing Group
Prophylaxis of the selected region for the study with Robson brush and prophylactic paste, washing and drying with cotton balls, followed by relative insulation with cotton rollers of the tooth in question, application of acid polyacrylic for 15 seconds throughout the surface, light drying with cotton ball, insertion of the high viscosity glass ionomer (Equia Forte in capsule - GC) through a specific applicator, after loss of the gloss of the digital pressure material with Vaseline for due drainage and surface protection of the material, removal of the excess, checking the occlusion with carbon paper, occlusal adjustments if necessary, superficial protection with petroleum jelly.
Interventions
Learn about the drugs, procedures, or behavioral strategies being tested and how they are applied within this trial.
Diode laser group
Prophylaxis of the selected region for the study with Robson brush and prophylactic paste, washing and drying, followed by application of diode laser (Sirolaser, Sirona Dental Systems GmbH, Bensheim, Germany) with wavelength of 970 nm +/- 10 nm, maximum power of 7 W CW, 1mW guide beam and 320μm optical fiber. Irradiation will be performed on the entire occlusal surface in contact mode, with power of 0.7 W (energy of 70 mJ) and frequency of 10 Hz for 30 seconds, having an energy density of 222.82 J / cm2. The FieldMaxII-TOP power meter (Coherent, Inc, USA) will be used prior to and after the applications. The laser will be applied in a sweeping motion throughout the affected surface, the fiber being maintained positioned perpendicular to the occlusal surface throughout the movement. The irradiation time will be standardized in 30 seconds.
Glass Ionomer Sealing Group
Prophylaxis of the selected region for the study with Robson brush and prophylactic paste, washing and drying with cotton balls, followed by relative insulation with cotton rollers of the tooth in question, application of acid polyacrylic for 15 seconds throughout the surface, light drying with cotton ball, insertion of the high viscosity glass ionomer (Equia Forte in capsule - GC) through a specific applicator, after loss of the gloss of the digital pressure material with Vaseline for due drainage and surface protection of the material, removal of the excess, checking the occlusion with carbon paper, occlusal adjustments if necessary, superficial protection with petroleum jelly.
Eligibility Criteria
Check the participation requirements, including inclusion and exclusion rules, age limits, and whether healthy volunteers are accepted.
Inclusion Criteria
* Children between 6 and 10 years old
Exclusion Criteria
* Teeth that presente sealants
* Enamel malformations that are specific to some syndromes
* Hypomineralized enamel affected by the ingestion of fluoride during enamel development
6 Years
10 Years
ALL
Yes
Sponsors
Meet the organizations funding or collaborating on the study and learn about their roles.
University of Sao Paulo
OTHER
Responsible Party
Identify the individual or organization who holds primary responsibility for the study information submitted to regulators.
Luciana Pion Antonio
Principal investigator
Locations
Explore where the study is taking place and check the recruitment status at each participating site.
Luciana Pion Antonio
Ribeirão Preto, São Paulo, Brazil
Countries
Review the countries where the study has at least one active or historical site.
Other Identifiers
Review additional registry numbers or institutional identifiers associated with this trial.
MIHForp
Identifier Type: -
Identifier Source: org_study_id
More Related Trials
Additional clinical trials that may be relevant based on similarity analysis.