Evaluation of Fixed Mandibular Retainer Using 3D Printed Positioning Tray Versus Direct Bonding Technique

NCT ID: NCT03572179

Last Updated: 2021-09-05

Study Results

Results pending

The study team has not published outcome measurements, participant flow, or safety data for this trial yet. Check back later for updates.

Basic Information

Get a concise snapshot of the trial, including recruitment status, study phase, enrollment targets, and key timeline milestones.

Recruitment Status

COMPLETED

Clinical Phase

NA

Total Enrollment

20 participants

Study Classification

INTERVENTIONAL

Study Start Date

2019-03-01

Study Completion Date

2020-03-28

Brief Summary

Review the sponsor-provided synopsis that highlights what the study is about and why it is being conducted.

Although there are many studies in the literature concerning methods of bonding of mandibular retainers whether directly or indirectly, there is a very limited evidence regarding their chair side time and bond failure. Also there are scarce data on fixed mandibular retainers bonded using 3D printed positioning tray.Thus, conducting a well-designed randomized clinical trial evaluating the chair side time and bond failure of 3d printed positioning tray and direct bonding method of fixed mandibular retainer.Null hypothesis is thatThe time needed for direct indirect bonding using 3D digital positioning tray of a mandibular fixed retainer is shorter than the time needed for direct bonding, and there is no difference in failures between the 2 bonding methods

Detailed Description

Dive into the extended narrative that explains the scientific background, objectives, and procedures in greater depth.

Statement of the problem:

\- Although there are many studies in the literature concerning methods of bonding of mandibular retainers whether directly or indirectly, there is a very limited evidence regarding their chair side time and bond failure. Also there are scarce data on fixed mandibular retainers bonded using 3D printed positioning tray.

Choice of the comparator:

In the ongoing study, direct bonding of mandibular fixed retainer will be the control group. Thus, conducting a well-designed randomized clinical trial evaluating the chair side time and bond failure of 3d printed positioning tray and direct bonding method of fixed mandibular retainer.

Study rationale:

To evaluate and compare bond failure and chair side time by 3D printed positioning tray and direct bonding method of mandibular fixed retainer.

Null hypothesis:

1. The time needed for direct indirect bonding using 3D digital positioning tray of a mandibular fixed retainer is shorter than the time needed for direct bonding, and (2) there is no difference in failures between the 2 bonding methods.

Research question:

Will the 3D digital positioning tray reduce chair side time, bond failure during retainer placement in patient with need of fixed bonded mandibular retainer, when compared to direct bonding method?

Aim of the study:

To evaluate chair side time and bond failure of 3D digital positioning tray during mandibular retainer placement and direct bonding of mandibular retainer.
2. Objectives

Primary objective To evaluate effect of 3D Digital positioning Tray on chair side time Secondary outcome Immediate bond failure and bond failure during first 6 month of placement of mandibular fixed retainer.

PICOTs format:

P: patient with the need of fixed bonded mandibular retainer after orthodontic treatment I: 3D printed Digital positioning Tray for bonding mandibular retainer. C: conventional direct bonding of mandibular retainer O: chair side time, immediate bond failure and bond failure during first 6 month.

Outcome Name,Measuring Tool and Measuring unit Primary is the Chair side Time measured by Digital stopwatch in Seconds Immediate Bond Failure is the Number of Debonded mandibular fixed retainer measured in Numerical value Bond failure during first 6 month follow up by the Number of Debonded mandibular fixed retainer measured in Numerical value

T: Immediate and T2: 6 month follow up S: Randomized controlled trial.
3. Trial Design This trial is designed as a parallel, randomized, controlled trial with allocation ratio 1:1.It will be performed at the educational hospital of the Faculty of Oral \& Dental Medicine, Cairo University.

Materials \& Methods:

I. Participants, Intervention and Outcomes

A) Study setting:

* Source of patients: patients who finished their orthodontic treatment at the outpatient clinic in Orthodontic department, Faculty of Oral and Dental Medicine, Cairo University, Cairo government, Egypt.
* Time: 2017-2018 The study will last for 6 months.

C) Intervention Treatment Group After finishing orthodontic treatment, all patient will receive a modified indirect technique for bonding fixed mandibular retainer and the key of modification is the fabrication of 3D printed digital positioning tray for placement of retainer with holes for composite pads for its direct application using 3 shape Ortho analyser Software ® instead of conventional indirect retainer fabrication method The sample selection and screening for inclusion of patients in clinical trial will be performed at all patients at clinic of Orthodontic department, Faculty of Oral and Dental Medicine, Cairo University.

Scanning of impression and designing the digital tray Lower impression is taken for each patient and the cast will be carefully scanned by desktop laser scanner for production of digital cast, using 3 shape ortho analyser Software®, the tray will be designed Fabrication and printing of the digital tray Using Dent1 3D printer® (Mogassam®, Greek campus, Cairo, Egypt), the tray will be printed Clinical application of the digital tray

* Teeth to be bonded are polished and etched.
* Teeth isolation \& moisture control are achieved.
* Dead Soft Stainless Steel wire is placed and adapted in its place in the digital tray.
* Placement of the tray in the patient mouth on the prepared teeth
* Adhesive bond is applied to teeth and then curing of the adhesive bonding.
* 3M ® composite (3M Unitek company , Monrovia, California, USA) is placed in the printed tray holes and any excess composite will be removed and then light curing is done.
* Time will be recorded during this step

Removal of digital tray After insuring complete curing of the composite the digital tray is then removed from patient mouth, Bond failure of composite pads will be checked in this step and recorded.

Control Group All patients of this group will follow conventional steps of direct bonding procedure of fixed mandibular retainer

* Pumice and polish the lingual surface of teeth on which retainer is to be bonded
* The retainer wire is prefabricated by incorporating perpendicular pieces of 1.5"-2" ligature wire at interdental region of respective teeth
* The retainer wire is then adapted on the tooth surface. The short ligatures are passed interdentally one occlusal to contact point and other gingival to contact point and tied over.
* Bonding procedure after etching and application of sealant is carried out.
* Enough adhesive should be used. Light curing is done.
* 3M ® composite (3M Unitek company, Monrovia, California, USA) is placed then light curing is done.
* Cut the ligature wires and pull them laically to disengage.
* Time will be recorded during this step

F) Sample Size calculation:

the sample is increased to a total size of 20 participants; 10 in each arm.

G) Recruitment strategy:

* Patients will be selected from the outpatient clinic of the orthodontic Department - Cairo University
* Consecutive sampling is done through screening of patients. This will continue until the target population is achieved.
* Identifying and recruiting potential subjects is achieved through patient database.

II. Assignment of Interventions

A) Sequence generation:

It will be performed as 1:1 allocation. The sequence of the two groups will be done by computer generated random numbers. This will be done by using Microsoft Office Excel 2013 sheet

B) Allocation Concealment:

Random numbers obtained by random sequence generation will be written on white papers, each paper will be kept in sealed envelope. Sealed envelopes will be kept in box at the secretary of orthodontic department office.

C) Implementation:

Implementation will be carried out in the secretary of the orthodontic department at the Faculty of Oral and Dental Medicine, Cairo University.

D) Blinding:

Participants Patients can detect the transfer tray so blinding is not possible Operator The main operator is responsible for the bonding so the blinding is not possible Assessor The assessor (different from main operator will carry out the measurement blindly

Conditions

See the medical conditions and disease areas that this research is targeting or investigating.

Orthodontic Appliance Complication

Study Design

Understand how the trial is structured, including allocation methods, masking strategies, primary purpose, and other design elements.

Allocation Method

RANDOMIZED

Intervention Model

PARALLEL

all patient will receive a modified indirect technique for bonding fixed mandibular retainer and the key of modification is the fabrication of 3D printed digital positioning tray for placement of retainer with holes for composite pads for its direct application using 3 shape Ortho analyser Software ® instead of conventional indirect retainer fabrication method
Primary Study Purpose

OTHER

Blinding Strategy

SINGLE

Outcome Assessors
Participants Patients can detect the transfer tray so blinding is not possible Operator The main operator is responsible for the bonding so the blinding is not possible Assessor The assessor (different from main operator will carry out the measurement blindly

Study Groups

Review each arm or cohort in the study, along with the interventions and objectives associated with them.

Treatment Group

After finishing orthodontic treatment, all patient will receive a modified indirect technique for bonding fixed mandibular retainer and the key of modification is the fabrication of 3D printed digital positioning tray for placement of retainer with holes for composite pads for its direct application using 3 shape Ortho analyser Software ® instead of conventional indirect retainer fabrication method

Group Type ACTIVE_COMPARATOR

3d printed positioning tray

Intervention Type DEVICE

3d printed positioning tray for lingual fixed retainer placement in treatment group

Control Group

All patients of this group will follow conventional steps of direct bonding procedure of fixed mandibular retainer

Group Type NO_INTERVENTION

No interventions assigned to this group

Interventions

Learn about the drugs, procedures, or behavioral strategies being tested and how they are applied within this trial.

3d printed positioning tray

3d printed positioning tray for lingual fixed retainer placement in treatment group

Intervention Type DEVICE

Eligibility Criteria

Check the participation requirements, including inclusion and exclusion rules, age limits, and whether healthy volunteers are accepted.

Inclusion Criteria

* • Patients with properly finished orthodontic treatment according to ABO standards.

* the presence of the 4 mandibular incisors and the 2 mandibular canines,
* No active caries, restorations, fractures, or periodontal disease of these teeth
* Patient with Good oral hygiene

Exclusion Criteria

* • Patients with no need of fixed bonded mandibular retainer

* No or poor patient's co operation
* Abnormal morphology of anterior teeth
* Bad oral hygiene
Eligible Sex

ALL

Accepts Healthy Volunteers

Yes

Sponsors

Meet the organizations funding or collaborating on the study and learn about their roles.

Raghda Alaa

OTHER

Sponsor Role lead

Responsible Party

Identify the individual or organization who holds primary responsibility for the study information submitted to regulators.

Raghda Alaa

principal investigator

Responsibility Role SPONSOR_INVESTIGATOR

Locations

Explore where the study is taking place and check the recruitment status at each participating site.

Cairo University Faculty of Oral and Dental Medicine

Cairo, , Egypt

Site Status

Countries

Review the countries where the study has at least one active or historical site.

Egypt

Other Identifiers

Review additional registry numbers or institutional identifiers associated with this trial.

CEBD-CU-2018-04-28

Identifier Type: -

Identifier Source: org_study_id

More Related Trials

Additional clinical trials that may be relevant based on similarity analysis.

Mandibular First Molar Distalization
NCT04229797 NOT_YET_RECRUITING NA