Proof-of-concept Study on Disinfection and Healing Acceleration Capabilities of 222nm Wave Length Narrow Band Ultraviolet Lighting Device

NCT ID: NCT03526068

Last Updated: 2019-02-15

Study Results

Results pending

The study team has not published outcome measurements, participant flow, or safety data for this trial yet. Check back later for updates.

Basic Information

Get a concise snapshot of the trial, including recruitment status, study phase, enrollment targets, and key timeline milestones.

Recruitment Status

COMPLETED

Clinical Phase

NA

Total Enrollment

16 participants

Study Classification

INTERVENTIONAL

Study Start Date

2016-12-31

Study Completion Date

2019-01-23

Brief Summary

Review the sponsor-provided synopsis that highlights what the study is about and why it is being conducted.

The threat of MRSA and multi-drug resistant pathogens have been growing in recent years. A new means of countering the infectious threat is required and one such modality is the use of UV light for disinfection. The aim of the study is to proof the efficacy of the 222nm UV light in disinfection on patients with sacral sores. This is a first in human proof-of-concept study

Detailed Description

Dive into the extended narrative that explains the scientific background, objectives, and procedures in greater depth.

Recent outbreaks of Ebola and MERS, and in the trend of growing threat of MRSA and multi-drug resistant pathogens, it is clear that a new means of countering the infectious threat is needed - even the US, EU, and Korean hospitals with the latest facilities has failed to stop the spread of these pathogens inside their wards.

This novel "Harmless UV Light," operating within the "Safe Zone Wave Length," will be a disruptive technology to counter the growing threats of infectious diseases, such as multi-drug-resistant bacteria and also viruses such as Ebola, MERS and new type Influenza. It will be a disruptive device in that it aims to be applied to fast, effective and labor-free disinfection of living environments, such as hospital wards, airports, and other public spaces to stop the spread of pathogens. This research is the first human clinical trial using this device that will spearhead the development of this technology, providing the key starting clinical data which would be the lead to development for a wider range of indications and markets. Successful proof of concept will lead to the next stage collaboration of larger scale clinical trials, and trials targeting wider range of indications and markets, at NUHS.

Conditions

See the medical conditions and disease areas that this research is targeting or investigating.

Ultraviolet Rays

Study Design

Understand how the trial is structured, including allocation methods, masking strategies, primary purpose, and other design elements.

Allocation Method

NA

Intervention Model

SINGLE_GROUP

Primary Study Purpose

TREATMENT

Blinding Strategy

NONE

Study Groups

Review each arm or cohort in the study, along with the interventions and objectives associated with them.

SafeZoneUVC

Patients were subjected to 90s UV light therapy of 540 mW/cm2 sessions 2 times a week for 2 weeks for a total of 4 sessions. Pre and post UV light therapy swabs were taken after standard wound irrigation

Group Type EXPERIMENTAL

SafeZoneUVC

Intervention Type DEVICE

SafeZoneUVC® uses a Krypton Chloride (Kr-Cl) excimer lamp as its light source. The Kr-Cl excimer lamp emits UVC light having a main wavelength of 222 nm when the Kr-Cl exciplex is deactivated to non-excited state molecule in the lamp. This 222 nm UVC light can inactivate bacteria, while the Kr-Cl excimer lamp also emits UVC light having a wavelength of 230 nm or more. SafeZoneUVC® effectively eliminates UVC light with a wavelength of 230 nm or more by incorporating an appropriate optical filter inside the unit and also utilizing an opaque guide to ensure that light is not dispersed beyond the target area.

Interventions

Learn about the drugs, procedures, or behavioral strategies being tested and how they are applied within this trial.

SafeZoneUVC

SafeZoneUVC® uses a Krypton Chloride (Kr-Cl) excimer lamp as its light source. The Kr-Cl excimer lamp emits UVC light having a main wavelength of 222 nm when the Kr-Cl exciplex is deactivated to non-excited state molecule in the lamp. This 222 nm UVC light can inactivate bacteria, while the Kr-Cl excimer lamp also emits UVC light having a wavelength of 230 nm or more. SafeZoneUVC® effectively eliminates UVC light with a wavelength of 230 nm or more by incorporating an appropriate optical filter inside the unit and also utilizing an opaque guide to ensure that light is not dispersed beyond the target area.

Intervention Type DEVICE

Eligibility Criteria

Check the participation requirements, including inclusion and exclusion rules, age limits, and whether healthy volunteers are accepted.

Inclusion Criteria

1. patients with pressure sore estimate at 2 cm X 2 cm or bigger
2. Patients with grade 2 or 3 sacral sores

Exclusion Criteria

1. Patient who has pressure sore exposing bone
2. Patient who are beyond the age limits
3. Patient who is septic
4. Patient with obviously infected wound / pus in the wound
5. Patient who is pregnant.
Minimum Eligible Age

21 Years

Maximum Eligible Age

100 Years

Eligible Sex

ALL

Accepts Healthy Volunteers

No

Sponsors

Meet the organizations funding or collaborating on the study and learn about their roles.

USHIO. INC

UNKNOWN

Sponsor Role collaborator

National University Hospital, Singapore

OTHER

Sponsor Role lead

Responsible Party

Identify the individual or organization who holds primary responsibility for the study information submitted to regulators.

Responsibility Role SPONSOR

Locations

Explore where the study is taking place and check the recruitment status at each participating site.

National University Hospital

Singapore, , Singapore

Site Status

Countries

Review the countries where the study has at least one active or historical site.

Singapore

Provided Documents

Download supplemental materials such as informed consent forms, study protocols, or participant manuals.

Document Type: Study Protocol

View Document

Other Identifiers

Review additional registry numbers or institutional identifiers associated with this trial.

2016/00105-AMD0001

Identifier Type: -