Accuracy Validation of Belun Oxygen Saturation Pulse Oximeter FDA Submission Study
NCT ID: NCT03439306
Last Updated: 2018-02-20
Study Results
The study team has not published outcome measurements, participant flow, or safety data for this trial yet. Check back later for updates.
Basic Information
Get a concise snapshot of the trial, including recruitment status, study phase, enrollment targets, and key timeline milestones.
COMPLETED
11 participants
OBSERVATIONAL
2017-03-15
2017-03-17
Brief Summary
Review the sponsor-provided synopsis that highlights what the study is about and why it is being conducted.
Related Clinical Trials
Explore similar clinical trials based on study characteristics and research focus.
Belun SpO2 Accuracy Comparison to Arterial Blood CO-Oximetry
NCT04873947
SpO2 Hypoxia Accuracy Validation Study
NCT03348189
SpO2 Accuracy Validation of Pulse Oximetry Systems During Motion and Non-Motion Conditions
NCT02475668
Accuracy Validation of the Cadwell Pulse Oximetry System
NCT02842476
SpO2 Accuracy In Vivo Testing for Neonates & Infants
NCT03843489
Detailed Description
Dive into the extended narrative that explains the scientific background, objectives, and procedures in greater depth.
The Clinimark proprietary Desaturation Fixture with Automated Data Collection is a single limb blow by system used to deliver medical grade oxygen and nitrogen gas mixtures to induce various hypoxic levels in subjects at a slow steady rate allowing an automatic marking and collection of the Control or secondary Transfer reference Pulse Oximeter and other pulse oximetry systems at 1 second intervals.
The Control Pulse Oximeter, an FDA cleared device, is used to monitor the oxygen saturation levels real time throughout the study for subject safety and to target stable plateaus. This device is used to assess the stability of the data.
Multi-parameter monitor used during the study to observe a subject's vital signs including ECG tracing, heart rate, respiratory rate, end-tidal CO2 with capnograph, secondary monitor for the oxygen concentration being delivered to the subject.
A whole blood analyzer (CO-Oximeter) is used as the reference standard device for obtaining the functional SaO2 value from arterial blood samples obtained during the study.
Conditions
See the medical conditions and disease areas that this research is targeting or investigating.
Study Design
Understand how the trial is structured, including allocation methods, masking strategies, primary purpose, and other design elements.
CASE_ONLY
PROSPECTIVE
Study Groups
Review each arm or cohort in the study, along with the interventions and objectives associated with them.
healthy adult volunteer
Subject is 18 to 50 years of age.
Subject is a non-smoker or who has not smoked within 2 days prior to the study.
Pulse Oximeter
The Pulse Oximeter are placed on the left and right Index fingers of each subject of the healthy adult volunteer group to evaluate the SpO2 accuracy performance.
Interventions
Learn about the drugs, procedures, or behavioral strategies being tested and how they are applied within this trial.
Pulse Oximeter
The Pulse Oximeter are placed on the left and right Index fingers of each subject of the healthy adult volunteer group to evaluate the SpO2 accuracy performance.
Eligibility Criteria
Check the participation requirements, including inclusion and exclusion rules, age limits, and whether healthy volunteers are accepted.
Inclusion Criteria
* Subject is 18 to 50 years of age.
* Subject must be willing and able to comply with study procedures and duration.
* Subject is a non-smoker or who has not smoked within 2 days prior to the study.
* Male or female of any race.
* Subject demographics include a range of skin pigmentations, including at least 2 darkly pigmented subjects or 15% of the subject pool, whichever is larger.
Exclusion Criteria
* Compromised circulation, injury, or physical malformation of fingers, toes, hands, ears or forehead/skull or other sensor sites which would limit the ability to test sites needed for the study. (Note: Certain malformations may still allow subjects to participate if the condition is noted and would not affect the particular sites utilized.)
* Females who are pregnant, who are trying to get pregnant, or have a urine test positive for pregnancy on the day of the study.
* Subjects with COHb levels larger than 3% as assessed with a Masimo Radical 7 (Rainbow).
* Subjects with known respiratory conditions such as (self-reported) uncontrolled / severe asthma, flu, pneumonia / bronchitis, shortness of breath / respiratory distress, respiratory or lung surgery, emphysema, COPD, lung disease.
* Subjects with known heart or cardiovascular conditions such as: (self-reported), except for blood pressure and ECG review) hypertension, have had cardiovascular surgery, Chest pain (angina), heart rhythms other than a normal sinus rhythm or with respiratory sinus arrhythmia, previous heart attack, blocked artery, unexplained shortness of breath, congestive heart failure (CHF), history of stroke, transient ischemic attack, carotid artery disease, myocardial ischemia, myocardial infarction, cardiomyopathy.
* Self-reported health conditions as identified in the Health Assessment Form (self-reported), diabetes, thyroid disease, kidney disease / chronic renal impairment, history of seizures (except childhood febrile seizures), epilepsy, history of unexplained syncope, recent history of frequent migraine headaches, recent head injury, cancer / chemotherapy.
* Subjects with known clotting disorders (self-reported) history of bleeding disorders or personal history of prolonged bleeding from injury, history of blood clots, hemophilia, current use of blood thinner: prescription or daily use of aspirin.
* Subjects with severe contact allergies to standard adhesives, latex or other materials found in pulse oximetry sensors, ECG electrodes, respiration monitor electrodes or other medical sensors (self-reported).
* Unwillingness or inability to remove colored nail polish from test digits.
* Other known health condition, should be considered upon disclosure in health assessment form.
18 Years
50 Years
ALL
Yes
Sponsors
Meet the organizations funding or collaborating on the study and learn about their roles.
Clinimark, LLC
OTHER
Belun Technology Company Limited
OTHER
Responsible Party
Identify the individual or organization who holds primary responsibility for the study information submitted to regulators.
Principal Investigators
Learn about the lead researchers overseeing the trial and their institutional affiliations.
Arthur Ruiz Cabrera, M.D.
Role: PRINCIPAL_INVESTIGATOR
Clinimark, LLC
Locations
Explore where the study is taking place and check the recruitment status at each participating site.
Clinimark, LLC
Louisville, Colorado, United States
Countries
Review the countries where the study has at least one active or historical site.
Other Identifiers
Review additional registry numbers or institutional identifiers associated with this trial.
PR-2016-207
Identifier Type: -
Identifier Source: org_study_id
More Related Trials