SpO2 Accuracy In Vivo Testing for Neonates & Infants

NCT ID: NCT03843489

Last Updated: 2024-08-28

Study Results

Results pending

The study team has not published outcome measurements, participant flow, or safety data for this trial yet. Check back later for updates.

Basic Information

Get a concise snapshot of the trial, including recruitment status, study phase, enrollment targets, and key timeline milestones.

Recruitment Status

WITHDRAWN

Clinical Phase

NA

Study Classification

INTERVENTIONAL

Study Start Date

2019-03-19

Study Completion Date

2021-09-20

Brief Summary

Review the sponsor-provided synopsis that highlights what the study is about and why it is being conducted.

The purpose of this clinical study is to validate the oxygen saturation (SpO2) accuracy of various pulse oximetry systems and sensors (new designs and/or reprocessed) during non-motion conditions as compared to arterial blood samples, drawn in the normal course of patient care, assessed by CO-Oximetry in neonates and infants. The primary end goal is to provide supporting documentation for the SpO2 accuracy of these pulse oximetry systems. The secondary end goal is to provide data for evaluation of clinical impact of measured to calculated SaO2 and related issues.

Detailed Description

Dive into the extended narrative that explains the scientific background, objectives, and procedures in greater depth.

FDA Guidance for pulse oximeters (March 4, 2013), section 4.1.2, In vivo testing for SpO2 accuracy for neonates, calls for the devices to be first tested in adults during hypoxia tests with arterial samples compared to measured oxygen saturation. This has been previously completed on the devices that will be tested in this protocol. In order to verify safe clinical performance in the neonate, the FDA then requires testing using neonatal arterial samples that are collected in the normal course of care; which is the primary purpose of this protocol. As a secondary purpose the data will be utilized to evaluate the impact of calculated oxygen saturation versus measured oxygen saturation and related issues.

Neonates/infants who will have an arterial line or sheath placed in the normal course of care will be included in this study. The pulse oximeter sensor must be placed on the Neonates/infant's foot or hand. Neonates who either have repaired PDA but are having the placement of the sensor on the foot (which will be arterial blood only) will be allowed as long as other inclusion/exclusion criteria are met.

Conditions

See the medical conditions and disease areas that this research is targeting or investigating.

Pulse Oximetry

Study Design

Understand how the trial is structured, including allocation methods, masking strategies, primary purpose, and other design elements.

Allocation Method

NON_RANDOMIZED

Intervention Model

PARALLEL

Hospital staff will place the pulse oximeter sensor(s) on one or both hand or feet of the neonate/infant and start the pulse oximeter data collection computer to record continuously. Each time an arterial CO-Oximeter sample is collected the data collection file will be marked by pressing the file marker key on the data collection computer. Information from each arterial CO-Oximeter sample will be written on the CRF. The arterial sample will always be measured in the reference co-oximeter. The sample may also be measured in the currently used AVOX 1000E.

This study will only use arterial blood samples that are taken in the normal course of care; the sample size of the blood draw will not be altered for this study (sample size will not be increased from the normal course of care for any portion of this study).
Primary Study Purpose

BASIC_SCIENCE

Blinding Strategy

NONE

Study Groups

Review each arm or cohort in the study, along with the interventions and objectives associated with them.

MEDLINE RENEWAL PULSE OXIMETRY SENSORS

Reference sensors from the reprocessed oximeter device will be placed on each subject to evaluate the SpO2 accuracy and performance.

Group Type EXPERIMENTAL

MEDLINE RENEWAL PULSE OXIMETRY SENSORS

Intervention Type DEVICE

An oximeter is a device used to transmit radiation at a known wavelength(s) through blood and to measure the blood oxygen saturation based on the amount of reflected or scattered radiation. Pulse oximetry monitoring is considered a standard physiological measurement and is used by clinicians in everyday situations to estimate arterial oxygen saturation. Because an arterial sample of blood is not required to make the measurement, the pulse oximeter can provide non-invasive real time information.

Reference CO-oximetry sensor

A whole blood analyzer (CO-Oximeter) is used as the reference standard device for obtaining the functional SaO2 value from arterial blood samples obtained during the study.

Group Type SHAM_COMPARATOR

Reference CO-oximetry sensor

Intervention Type DEVICE

A whole blood analyzer (CO-Oximeter) is used as the reference standard device for obtaining the functional SaO2 value from arterial blood samples obtained during the study.

Interventions

Learn about the drugs, procedures, or behavioral strategies being tested and how they are applied within this trial.

MEDLINE RENEWAL PULSE OXIMETRY SENSORS

An oximeter is a device used to transmit radiation at a known wavelength(s) through blood and to measure the blood oxygen saturation based on the amount of reflected or scattered radiation. Pulse oximetry monitoring is considered a standard physiological measurement and is used by clinicians in everyday situations to estimate arterial oxygen saturation. Because an arterial sample of blood is not required to make the measurement, the pulse oximeter can provide non-invasive real time information.

Intervention Type DEVICE

Reference CO-oximetry sensor

A whole blood analyzer (CO-Oximeter) is used as the reference standard device for obtaining the functional SaO2 value from arterial blood samples obtained during the study.

Intervention Type DEVICE

Eligibility Criteria

Check the participation requirements, including inclusion and exclusion rules, age limits, and whether healthy volunteers are accepted.

Inclusion Criteria

* Neonates/Infants up to 28 days old
* Neonates/Infants less than 5kg.

And one of the following:

Without PDA With a PDA with R-L shunting that will be repaired before arterial samples are taken

Exclusion Criteria

* Physical malformation of feet or toes or other sensor sites which would limit the ability to place the sensors for the study.
* Neonates/Infants older than 28 days old.
* Neonates/Infants outside the weight range for the sensor (Greater than 5kg.)
* Neonates/Infants with unrepaired PDA. with PDA with R-L shunting
* Subjects who are undergoing bilirubin light therapy while samples are being obtained.
Maximum Eligible Age

28 Days

Eligible Sex

ALL

Accepts Healthy Volunteers

Yes

Sponsors

Meet the organizations funding or collaborating on the study and learn about their roles.

Clinimark, LLC

OTHER

Sponsor Role collaborator

Medline Industries

INDUSTRY

Sponsor Role lead

Responsible Party

Identify the individual or organization who holds primary responsibility for the study information submitted to regulators.

Responsibility Role SPONSOR

Principal Investigators

Learn about the lead researchers overseeing the trial and their institutional affiliations.

Robin Deterding, MD

Role: PRINCIPAL_INVESTIGATOR

Children's Hospital Colorado

Locations

Explore where the study is taking place and check the recruitment status at each participating site.

Children's Hospital Colorado

Aurora, Colorado, United States

Site Status

Countries

Review the countries where the study has at least one active or historical site.

United States

Other Identifiers

Review additional registry numbers or institutional identifiers associated with this trial.

PR2018-296

Identifier Type: -

Identifier Source: org_study_id

More Related Trials

Additional clinical trials that may be relevant based on similarity analysis.

Pulse Oximetry Performance Comparison in Newborns
NCT06637917 ACTIVE_NOT_RECRUITING
SpO2 Accuracy in Children
NCT07168798 ENROLLING_BY_INVITATION