Induced Hypoxia Study for Validation of SpO2 Accuracy

NCT ID: NCT00788983

Last Updated: 2013-09-20

Study Results

Results pending

The study team has not published outcome measurements, participant flow, or safety data for this trial yet. Check back later for updates.

Basic Information

Get a concise snapshot of the trial, including recruitment status, study phase, enrollment targets, and key timeline milestones.

Recruitment Status

COMPLETED

Total Enrollment

12 participants

Study Classification

OBSERVATIONAL

Study Start Date

2008-11-30

Study Completion Date

2008-11-30

Brief Summary

Review the sponsor-provided synopsis that highlights what the study is about and why it is being conducted.

Validate Non-Motion SpO2 Accuracy from 70%-100% of various pulse oximeter/ sensor combinations and various OEM pulse oximeter modules and sensor combinations during induced hypoxia (desaturation).

Detailed Description

Dive into the extended narrative that explains the scientific background, objectives, and procedures in greater depth.

The testing is conducted on 12 healthy, consenting, non-smoking subjects in accordance with the IRB approved Protocol. The subjects shall be distributed across both genders and a range of skin tones as equally as practical.

An arterial line will be placed in the radial artery of each subject's right arm, and sensors will be attached to each subject. The subjects will be placed in a semi-supine position and allowed to breathe through a mouthpiece while the nose is blocked with a nose-clip.

Hypoxia will be induced by on each subject, as levels of oxyhemoglobin saturation (between 70% and 100%) are achieved by breathing mixtures of nitrogen, room air and carbon dioxide. Inspired O2 concentration will be adjusted breath-by-breath using a computed saturation, based on end-tidal PO2 and PCO2, as sampled by a mass spectrometer. Predicted levels of oxyhemoglobin saturations will be attained and held stable. At a minimum of sixty seconds into each plateau, a 0.5cc waste blood draw through the arterial line, followed by the first 1.0cc sample blood draw. After approximately thirty additional seconds, the second 1.0cc sample blood draw will be taken. The samples will immediately be analyzed by a Radiometer OSM-3 multi-wavelength co-oximeter and recorded. The SpO2 data from the oximeters will be collected via a laptop computer. Concurrent with the end of each blood draw, a marker will be generated on the laptop computers to identify the event.

Conditions

See the medical conditions and disease areas that this research is targeting or investigating.

Hypoxia

Keywords

Explore important study keywords that can help with search, categorization, and topic discovery.

Induced hypoxia Pulse oximeter Nonin Medical Verification of SpO2 accuracy

Study Design

Understand how the trial is structured, including allocation methods, masking strategies, primary purpose, and other design elements.

Study Time Perspective

PROSPECTIVE

Eligibility Criteria

Check the participation requirements, including inclusion and exclusion rules, age limits, and whether healthy volunteers are accepted.

Inclusion Criteria

* Non-smokers
* Healthy; no known blood disorders
* Finger sizes within the sensor specifications
* Minimum 18 years of age

Exclusion Criteria

* Artificial nails or fingernail polish
Minimum Eligible Age

18 Years

Maximum Eligible Age

40 Years

Eligible Sex

ALL

Accepts Healthy Volunteers

Yes

Sponsors

Meet the organizations funding or collaborating on the study and learn about their roles.

Nonin Medical, Inc

INDUSTRY

Sponsor Role lead

Responsible Party

Identify the individual or organization who holds primary responsibility for the study information submitted to regulators.

Responsibility Role SPONSOR

Principal Investigators

Learn about the lead researchers overseeing the trial and their institutional affiliations.

Philip E Bickler, MD

Role: PRINCIPAL_INVESTIGATOR

University of California, San Francisco

Locations

Explore where the study is taking place and check the recruitment status at each participating site.

University of California, San Francisco, Induced Hypoxia Lab

San Francisco, California, United States

Site Status

Countries

Review the countries where the study has at least one active or historical site.

United States

Other Identifiers

Review additional registry numbers or institutional identifiers associated with this trial.

112008

Identifier Type: -

Identifier Source: org_study_id