Respiratory Rates - Accuracy of Contact-free Monitoring of Respiratory Rates
NCT ID: NCT03393585
Last Updated: 2018-04-23
Study Results
The study team has not published outcome measurements, participant flow, or safety data for this trial yet. Check back later for updates.
Basic Information
Get a concise snapshot of the trial, including recruitment status, study phase, enrollment targets, and key timeline milestones.
COMPLETED
650 participants
OBSERVATIONAL
2017-12-23
2018-04-06
Brief Summary
Review the sponsor-provided synopsis that highlights what the study is about and why it is being conducted.
The goal of this study is to test the accuracy of the same system in real patients in the triage setting of an Emergency Department (ED).
Related Clinical Trials
Explore similar clinical trials based on study characteristics and research focus.
Accuracy of the Welch Allyn ConnexSpot Monitor in Measuring Respiratory Rate in the Emergency Department
NCT07299968
Targeting of UnControlled Hypertension in Emergency Department
NCT03749499
BNP Measurement Reduces Resource Utilization for Patients With CHF Admitted Thorough the ED
NCT00587938
Heart Rate Variability At the Emergency Department
NCT05093439
Vibration Response Imaging (VRI) in Dyspnea Patients Presenting to the ED
NCT01206621
Detailed Description
Dive into the extended narrative that explains the scientific background, objectives, and procedures in greater depth.
According to the guidelines the respiratory rate is visually counted for one minute (WHOrecommendation) by a triage nurse.
Simultaneously in addition to the visual counting, it is planned to measure the same vital sign as part of our study also through a camera-based prototype application (CBPA) and capnography as a gold standard.
Hence the triage process is not prolongated through our study, only completed and a guideline compliant procedure is ensured which is only performed in a relatively low percentage in the ED of the University Hospital Basel. Clinical decisions are exclusively based on the actual clinical standard of visual counting and are not influenced by the measurements of our study.
For the capnography, which were considered as the most accurate method, the patient wears a nasal sample line (Philips® Heartstart MRx mit Philips® Smart CapnoLine™PlusO2Long Oral/Nasal Sample Line).
The CBPA system consists of a notebook (HP Zbook 15 G3, S/N: CND705IXT6), USB-camera with lens (Tamron CCTV lens, CE 4402789484; UI3060 camera, 20170329-E347840), USB-harddrive (Western digital R/N D8B, S/N: WXA1E661J0XJ) to save the signals and an implement camera-based algorithm for extraction of breathing signals. The camera is pointing towards the torso of the patient to display it on the screen in a real-time application. The software is able to detect the respiratory-specific chest movements and generates a respiratory wave on the computer. From the configuration and frequency of these respiratory waves the software calculates the respiratory rate. No videos are recorded.
The data is acquired in a standardised protocol and stored coded in an Access®-database. To prevent potential bias the vital signs will be written down in the following order: 1. RR by visual counting 2. RR by CBPA 3. RR by capnography. The measurements take place in rooms of the ED which are designated to triage emergency patients.
As possible confounders sex, age and BMI are registered.
Conditions
See the medical conditions and disease areas that this research is targeting or investigating.
Study Design
Understand how the trial is structured, including allocation methods, masking strategies, primary purpose, and other design elements.
OTHER
PROSPECTIVE
Interventions
Learn about the drugs, procedures, or behavioral strategies being tested and how they are applied within this trial.
touchless vital signs monitoring
We measure Respiratory Rates in the Triage of Patients entering an Emergency Department by three different methods.
Eligibility Criteria
Check the participation requirements, including inclusion and exclusion rules, age limits, and whether healthy volunteers are accepted.
Inclusion Criteria
Exclusion Criteria
18 Years
ALL
No
Sponsors
Meet the organizations funding or collaborating on the study and learn about their roles.
Philips Healthcare
INDUSTRY
Christian Nickel
OTHER
Responsible Party
Identify the individual or organization who holds primary responsibility for the study information submitted to regulators.
Christian Nickel
PD MD
Principal Investigators
Learn about the lead researchers overseeing the trial and their institutional affiliations.
Christian H Nickel, PD Dr. med
Role: PRINCIPAL_INVESTIGATOR
Emergency Department, University Hospital Basel
Locations
Explore where the study is taking place and check the recruitment status at each participating site.
University Hospital Basel
Basel, , Switzerland
Countries
Review the countries where the study has at least one active or historical site.
References
Explore related publications, articles, or registry entries linked to this study.
Hodgetts TJ, Kenward G, Vlachonikolis IG, Payne S, Castle N. The identification of risk factors for cardiac arrest and formulation of activation criteria to alert a medical emergency team. Resuscitation. 2002 Aug;54(2):125-31. doi: 10.1016/s0300-9572(02)00100-4.
Strauss R, Ewig S, Richter K, Konig T, Heller G, Bauer TT. The prognostic significance of respiratory rate in patients with pneumonia: a retrospective analysis of data from 705,928 hospitalized patients in Germany from 2010-2012. Dtsch Arztebl Int. 2014 Jul 21;111(29-30):503-8, i-v. doi: 10.3238/arztebl.2014.0503.
Bone RC, Sprung CL, Sibbald WJ. Definitions for sepsis and organ failure. Crit Care Med. 1992 Jun;20(6):724-6. doi: 10.1097/00003246-199206000-00002. No abstract available.
Brabrand M, Havshoj U, Graham CA. Validation of the qSOFA score for identification of septic patients: A retrospective study. Eur J Intern Med. 2016 Dec;36:e35-e36. doi: 10.1016/j.ejim.2016.09.004. Epub 2016 Sep 15. No abstract available.
Mower WR, Sachs C, Nicklin EL, Safa P, Baraff LJ. A comparison of pulse oximetry and respiratory rate in patient screening. Respir Med. 1996 Nov;90(10):593-9. doi: 10.1016/s0954-6111(96)90017-7.
Subbe CP, Kruger M, Rutherford P, Gemmel L. Validation of a modified Early Warning Score in medical admissions. QJM. 2001 Oct;94(10):521-6. doi: 10.1093/qjmed/94.10.521.
Goldhill DR, White SA, Sumner A. Physiological values and procedures in the 24 h before ICU admission from the ward. Anaesthesia. 1999 Jun;54(6):529-34. doi: 10.1046/j.1365-2044.1999.00837.x.
Grossmann FF, Nickel CH, Christ M, Schneider K, Spirig R, Bingisser R. Transporting clinical tools to new settings: cultural adaptation and validation of the Emergency Severity Index in German. Ann Emerg Med. 2011 Mar;57(3):257-64. doi: 10.1016/j.annemergmed.2010.07.021. Epub 2010 Oct 16.
Hossein Nejad H, Banaie M, Seyedhosseini Davarani SH, Khazaeipour Z. Evaluation of the Significance of Vital Signs in the Up-Triage of Patients Visiting Emergency Department from Emergency Severity Index Level 3 to 2. Acta Med Iran. 2016 Jun;54(6):366-9.
Hogan J. Why don't nurses monitor the respiratory rates of patients? Br J Nurs. 2006 May 11-24;15(9):489-92. doi: 10.12968/bjon.2006.15.9.21087.
Lovett PB, Buchwald JM, Sturmann K, Bijur P. The vexatious vital: neither clinical measurements by nurses nor an electronic monitor provides accurate measurements of respiratory rate in triage. Ann Emerg Med. 2005 Jan;45(1):68-76. doi: 10.1016/j.annemergmed.2004.06.016.
Edmonds ZV, Mower WR, Lovato LM, Lomeli R. The reliability of vital sign measurements. Ann Emerg Med. 2002 Mar;39(3):233-7. doi: 10.1067/mem.2002.122017.
Folke M, Cernerud L, Ekstrom M, Hok B. Critical review of non-invasive respiratory monitoring in medical care. Med Biol Eng Comput. 2003 Jul;41(4):377-83. doi: 10.1007/BF02348078.
Becker C, Achermann S, Rocque M, Kirenko I, Schlack A, Dreher-Hummel T, Zumbrunn T, Bingisser R, Nickel CH. Camera-based measurement of respiratory rates is reliable. Eur J Emerg Med. 2018 Dec;25(6):416-422. doi: 10.1097/MEJ.0000000000000476.
Flahault A, Cadilhac M, Thomas G. Sample size calculation should be performed for design accuracy in diagnostic test studies. J Clin Epidemiol. 2005 Aug;58(8):859-62. doi: 10.1016/j.jclinepi.2004.12.009.
Caspar M, Dutilh G, Achermann S, Bingisser R, Nickel CH. Contact-Free Monitoring of Pulse Rate For Triage of Patients Presenting to the Emergency Department. J Emerg Med. 2021 Dec;61(6):649-657. doi: 10.1016/j.jemermed.2021.07.005. Epub 2021 Aug 30.
Achermann S, Caspar M, Wirth C, Becker C, Rocque M, Kirenko I, Schlack A, Dutilh G, Bingisser R, Nickel CH. Contact-free monitoring of respiratory rates for triage of patients presenting to the emergency department. Resuscitation. 2019 Apr;137:154-155. doi: 10.1016/j.resuscitation.2019.01.041. Epub 2019 Feb 18. No abstract available.
Other Identifiers
Review additional registry numbers or institutional identifiers associated with this trial.
EKNZ 2017-01583
Identifier Type: OTHER
Identifier Source: secondary_id
Resprate 2017
Identifier Type: -
Identifier Source: org_study_id