Feasibility Study of Compensation for Blindness With the PRIMA System in Patients With Dry Age Related Macular Degeneration

NCT ID: NCT03333954

Last Updated: 2025-04-06

Study Results

Results pending

The study team has not published outcome measurements, participant flow, or safety data for this trial yet. Check back later for updates.

Basic Information

Get a concise snapshot of the trial, including recruitment status, study phase, enrollment targets, and key timeline milestones.

Recruitment Status

COMPLETED

Clinical Phase

NA

Total Enrollment

5 participants

Study Classification

INTERVENTIONAL

Study Start Date

2017-11-06

Study Completion Date

2024-12-12

Brief Summary

Review the sponsor-provided synopsis that highlights what the study is about and why it is being conducted.

In this study, the principle functionality of the device will be tested in humans for the first time. The study will evaluate the extent to which patients with atrophic dry age related macular degeneration (AMD) have evoked light perception using the implant.

Detailed Description

Dive into the extended narrative that explains the scientific background, objectives, and procedures in greater depth.

In this study subjects are provided with a PRIMA sub-retinal implant in one eye. A camera integrated in the external components of the implant captures visual information of the environment, this information is processed by a pocket processor and then transmitted via projected IR light onto the implant. The implant received the projected IR light and stimulates the nerve cells of the retina. Interim analysis will be performed at 6 months after implantation.

Conditions

See the medical conditions and disease areas that this research is targeting or investigating.

Dry Age-related Macular Degeneration

Study Design

Understand how the trial is structured, including allocation methods, masking strategies, primary purpose, and other design elements.

Allocation Method

NA

Intervention Model

SINGLE_GROUP

Primary Study Purpose

TREATMENT

Blinding Strategy

NONE

Interventions

Learn about the drugs, procedures, or behavioral strategies being tested and how they are applied within this trial.

PRIMA

The PRIMA Bionic Vision System is a device for treatment of patients who have lost their sight through outer retinal degenerative conditions of the eye such as atrophic dry age related macular degeneration.

The PRIMA System is designed to provide partial restoration of the patient's visual function through electrical stimulation of the retinal neurons by a sub-retinally implanted stimulator that replace part of the degenerate photoreceptors

Intervention Type DEVICE

Eligibility Criteria

Check the participation requirements, including inclusion and exclusion rules, age limits, and whether healthy volunteers are accepted.

Inclusion Criteria

* Is 60 years or older at the date of enrolment;
* Has a confirmed diagnosis of advanced dry age related macular degeneration with an atrophy size of at least 3 optic disc diameters;
* Has best corrected visual acuity of the study eye of logMAR 1.3 (20/400) or worse measured by ETDRS;
* Has no foveal perception measured by micro-perimetry in the study eye (≤ 4 dB on Opko scale or equivalent) ;
* Has a study eye that is able to perceive light;
* Has useful vision on the non-study eye;
* Has a refraction of study eye between -3 and + 4 (limits included) for patient with IOL (there is no refraction criteria for patients with natural lens);
* Understands and accepts the obligation to present for all schedule follow-up visits.
* Patient signed informed consent

Exclusion Criteria

* Has cataracts that may influence the visual function of the study eye;
* Has an aphakic study eye
* Had cataract surgery in the last 1 month;
* Active sub-macular choroidal neovascularization in the study eye;
* Has any disease (other than study allowed diseases) or condition that affects retinal function of the study eye (e.g., central retinal artery/vein occlusion, end-stage diabetic retinopathy, retinal detachment, infectious or inflammatory retinal disease, severe glaucoma, optic neuropathy, myopic chorio-retinal atrophy etc.);
* Has an implanted telescope in one eye;
* Has any disease or condition that prevents adequate examination of the study eye including, but not limited to, corneal degeneration that cannot be resolved prior to implantation. Note, that this criterion is also important for the function of the implant;
* Has an endothelia cell count of less than 1000 cells/mm² in the study eye;
* Suffers from nystagmus;
* Has any disease or condition that precludes the understanding or communication of the informed consent, study requirements or test protocols (e.g., deafness, severe multiple sclerosis, amyotrophic lateral sclerosis, severe neuritis, etc);
* Has a history of epileptic seizure;
* Has a history of chronic or recurrent infection or inflammation that would preclude participation in the study;
* Has a known sensitivity to the contact materials of the implant (iridium oxide, silicon-carbide and titanium);
* Presents with hypotony in the study eye;
* Presents with hypertony in the study eye;
* Has another active implanted device (e.g. cochlear implant, pacemaker) that may interfere with the device function, or diagnoses requiring such an active implant;
* Has active cancer or a history of intraocular, optic nerve or brain cancer and metastasis;
* Is an immune-suppressed subject (e.g., due to HIV positive diagnosis, etc.);
* Is carrier of multi-resistant germs;
* Is receiving anticoagulation therapy that cannot be adapted to allow eye surgery;
* Is participating in another investigational drug or device study that may interfere with the present study;
* Patients with recurrent or chronic inflammations or infections are excluded from the study. Specifically, patients with the following disorders are excluded:

* Common inflammation - severe chronic and consuming diseases that frequently associated with infection (e.g. Crohn disease, Whipple's disease);
* Active inflammation in the area of the eye (e.g. herpes of cornea and/or conjunctiva, recurrent blepharoconjunctivitis, hordeolum, chalazion);
* Has a severe psychological disorder. When in any doubt, an expert assessment needs to be arranged to clarify whether the patient's psychological health is suitable for the trial. In any doubts of the subjects psychological status a clinical psychologist, psychologist or the community doctor/general practitioner should be involved. The patient must have the legal capacity to sign the informed consent;
* Has severe renal, cardiac, hepatic etc. organ diseases;
* Has head dimension that are incompatible with the Visual Interface.
* Has too high and unrealistic expectation (e.g., believes that a benefit is guaranteed or expect normal vision after surgery)
Minimum Eligible Age

60 Years

Eligible Sex

ALL

Accepts Healthy Volunteers

No

Sponsors

Meet the organizations funding or collaborating on the study and learn about their roles.

Science Corporation

INDUSTRY

Sponsor Role lead

Responsible Party

Identify the individual or organization who holds primary responsibility for the study information submitted to regulators.

Responsibility Role SPONSOR

Locations

Explore where the study is taking place and check the recruitment status at each participating site.

Fondation Ophtalmologique A. De Rothschild/ Hopital des Quinze Vingts/

Paris, , France

Site Status

Countries

Review the countries where the study has at least one active or historical site.

France

References

Explore related publications, articles, or registry entries linked to this study.

Muqit MMK, Le Mer Y, Olmos de Koo L, Holz FG, Sahel JA, Palanker D. Prosthetic Visual Acuity with the PRIMA Subretinal Microchip in Patients with Atrophic Age-Related Macular Degeneration at 4 Years Follow-up. Ophthalmol Sci. 2024 Mar 7;4(5):100510. doi: 10.1016/j.xops.2024.100510. eCollection 2024 Sep-Oct.

Reference Type DERIVED
PMID: 38881600 (View on PubMed)

Muqit M, Mer YL, de Koo LO, Holz FG, Sahel JA, Palanker D. Prosthetic Visual Acuity with the PRIMA System in Patients with Atrophic Age-related Macular Degeneration at 4 years follow-up. medRxiv [Preprint]. 2023 Nov 13:2023.11.12.23298227. doi: 10.1101/2023.11.12.23298227.

Reference Type DERIVED
PMID: 38014146 (View on PubMed)

Palanker D, Le Mer Y, Mohand-Said S, Sahel JA. Simultaneous perception of prosthetic and natural vision in AMD patients. Nat Commun. 2022 Jan 26;13(1):513. doi: 10.1038/s41467-022-28125-x.

Reference Type DERIVED
PMID: 35082313 (View on PubMed)

Palanker D, Le Mer Y, Mohand-Said S, Muqit M, Sahel JA. Photovoltaic Restoration of Central Vision in Atrophic Age-Related Macular Degeneration. Ophthalmology. 2020 Aug;127(8):1097-1104. doi: 10.1016/j.ophtha.2020.02.024. Epub 2020 Feb 25.

Reference Type DERIVED
PMID: 32249038 (View on PubMed)

Other Identifiers

Review additional registry numbers or institutional identifiers associated with this trial.

CIP-PRIMA-FS

Identifier Type: -

Identifier Source: org_study_id

More Related Trials

Additional clinical trials that may be relevant based on similarity analysis.