Evaluation of Cerebral Elastography by Magnetic Resonance: Comparison of Healthy Subjects and Patients With Glial Tumor
NCT ID: NCT03274037
Last Updated: 2017-09-08
Study Results
The study team has not published outcome measurements, participant flow, or safety data for this trial yet. Check back later for updates.
Basic Information
Get a concise snapshot of the trial, including recruitment status, study phase, enrollment targets, and key timeline milestones.
UNKNOWN
NA
48 participants
INTERVENTIONAL
2017-07-07
2020-07-07
Brief Summary
Review the sponsor-provided synopsis that highlights what the study is about and why it is being conducted.
Neurodegenerative diseases (Alzheimer's, Parkinson's, Creutzfeldt-Jakobes) and cancers largely modify the mechanical properties of the affected tissues. For a first evaluation of the technique, we are interested in glial tumors representing half of the intracranial tumors in adults (incidence: 5 cases per 100 000 inhabitants), the second cancer in children and the third cause of death in l Young adult.
Related Clinical Trials
Explore similar clinical trials based on study characteristics and research focus.
Remote Brain Microhaemorrhages May Predict Haematoma in Glioma Patients Treated With Radiation Therapy
NCT03973892
Magnetic Resonance Elastography in Patients With Acute Closed Traumatic Brain Injury
NCT04361578
Longitudinal MRI Assessment in Patients With Diffuse Low-grade Gliomas
NCT04346472
ChAracterization of Normal and Pathological moRphological Variations of the TEMporomandibular Joint by Real-time magnetIc reSonance Imaging
NCT06070558
Concordance and Accuracy of MRI in the Detection of Meningiomas: Optimizing Sequences With Low Doses of Gadolinium
NCT04113395
Detailed Description
Dive into the extended narrative that explains the scientific background, objectives, and procedures in greater depth.
The elasticity measured by MRI of tumors of 38 to 75 mm in diameter could also be correlated with the tissue consistency of the samples obtained during a surgical reduction. Finally, in a patient with a temporal glioma, the mean modulus of elasticity in the tumor region was measured by elastography close to 30% greater than in the corresponding region of the healthy hemisphere.
But the difficulty of introducing a mechanical wave into the brain through the cranial chamber and the surrounding cerebro-spinal fluid limits the scope of the advanced results, which are essentially qualitative at the moment. The median amplitude of the displacements measured in the brain during these studies is only 7.33 μm at 40 Hz and drops to 2.70 μm at 120 Hz while it is more than 21 μm in the Liver and breast at 75 and 90 Hz respectively4. Recently, the IR4M has developed an original excitation device that allows to circumvent this limit. Displacements of cerebral tissues of several tens of micrometers have been reported by MRI and the inversion of the problem leading to the viscoelastic modules could be carried out on the whole of the human brain
Conditions
See the medical conditions and disease areas that this research is targeting or investigating.
Study Design
Understand how the trial is structured, including allocation methods, masking strategies, primary purpose, and other design elements.
NA
SINGLE_GROUP
DIAGNOSTIC
NONE
Study Groups
Review each arm or cohort in the study, along with the interventions and objectives associated with them.
Examination of cerebral MRI elastography
The mechanical waves will be induced by pressure waves guided to the mouth of the elongated subject in the MRI
Device for mechanical excitation by pressure waves
The IRM elastography technique, proven and patented in 2010 by the IR4M (Orsay, France), consists in characterizing by IRM induced waves in the human body in order to determine the mechanical properties Of the target organ.
The mechanical waves will be induced by pressure waves guided at the mouth of the subject elongated in the MRI and consisting of a function generator at a frequency between 5 Hz and 500 Hz, linear amplifier , An electromechanical transducer, a waveguide whose length is adapted to the chosen excitation frequency, an antibacterial filter and a disposable mouthpiece
The MRI imager Achieva 1.5 T MRI (Philips Healthcare, Best, the Netherlands) and the SIGNA Architect GEM 3.0T (GE medical systems, LLC, USA) system will be used to measure brain tissue displacement fields.
Interventions
Learn about the drugs, procedures, or behavioral strategies being tested and how they are applied within this trial.
Device for mechanical excitation by pressure waves
The IRM elastography technique, proven and patented in 2010 by the IR4M (Orsay, France), consists in characterizing by IRM induced waves in the human body in order to determine the mechanical properties Of the target organ.
The mechanical waves will be induced by pressure waves guided at the mouth of the subject elongated in the MRI and consisting of a function generator at a frequency between 5 Hz and 500 Hz, linear amplifier , An electromechanical transducer, a waveguide whose length is adapted to the chosen excitation frequency, an antibacterial filter and a disposable mouthpiece
The MRI imager Achieva 1.5 T MRI (Philips Healthcare, Best, the Netherlands) and the SIGNA Architect GEM 3.0T (GE medical systems, LLC, USA) system will be used to measure brain tissue displacement fields.
Eligibility Criteria
Check the participation requirements, including inclusion and exclusion rules, age limits, and whether healthy volunteers are accepted.
Inclusion Criteria
* Ability to hold in an MRI device without moving
* No known and diagnosed neurological pathologies such as stroke, cerebral surgery, central nervous system tumor, inflammatory disease (such as multiple sclerosis), neurodegenerative disease (such as Alzheimer's, Parkinson's or Creutzfeldt-Jakobes's ), depression
* Informed consent
* Age between 18 and 65 years
* Ability to hold in an MRI device without moving
* Glial tumor greater than 3 mm diagnosed by standard MRI
* Informed and informed consent
Exclusion Criteria
* Non-affiliation to a social security scheme (beneficiary or beneficiary)
* Intercurrent disorder likely to disrupt test results
* Patient under anticoagulant:
18 Years
65 Years
ALL
Yes
Sponsors
Meet the organizations funding or collaborating on the study and learn about their roles.
Assistance Publique - Hôpitaux de Paris
OTHER
Responsible Party
Identify the individual or organization who holds primary responsibility for the study information submitted to regulators.
Principal Investigators
Learn about the lead researchers overseeing the trial and their institutional affiliations.
Denis MD DUCREUX, PhD
Role: PRINCIPAL_INVESTIGATOR
Assistance publique des hopitaux de paris
Locations
Explore where the study is taking place and check the recruitment status at each participating site.
Denis DUCREUX
Le Kremlin-Bicêtre, France, France
Countries
Review the countries where the study has at least one active or historical site.
Central Contacts
Reach out to these primary contacts for questions about participation or study logistics.
Facility Contacts
Find local site contact details for specific facilities participating in the trial.
Other Identifiers
Review additional registry numbers or institutional identifiers associated with this trial.
IDRCB: 2013-A00289-36
Identifier Type: -
Identifier Source: org_study_id
More Related Trials