Dimensional Accuracy of Complete Denture With Rapid Prototyping and Conventional Method
NCT ID: NCT03119753
Last Updated: 2017-04-19
Study Results
The study team has not published outcome measurements, participant flow, or safety data for this trial yet. Check back later for updates.
Basic Information
Get a concise snapshot of the trial, including recruitment status, study phase, enrollment targets, and key timeline milestones.
UNKNOWN
NA
14 participants
INTERVENTIONAL
2017-06-10
2017-09-10
Brief Summary
Review the sponsor-provided synopsis that highlights what the study is about and why it is being conducted.
We hypothesize that both techniques do not significantly differ from each other
Related Clinical Trials
Explore similar clinical trials based on study characteristics and research focus.
Patient Satisfaction and Retention of Upper Complete Denture Base Using Rapid Prototyping Versus a Conventional One
NCT03354715
Retention of Complete Denture Using Rapid Prototyping
NCT03507179
Complete Denture Tooth Movement in Digital Light Processing Versus Conventional Fabrication Techniques
NCT04025697
Accuracy of 3D Printed Maxillary Complete Dentures
NCT03613896
Manually Versus Digitally Fabricated Removable Partial Dentures
NCT01191073
Detailed Description
Dive into the extended narrative that explains the scientific background, objectives, and procedures in greater depth.
Conditions
See the medical conditions and disease areas that this research is targeting or investigating.
Study Design
Understand how the trial is structured, including allocation methods, masking strategies, primary purpose, and other design elements.
RANDOMIZED
PARALLEL
OTHER
QUADRUPLE
Study Groups
Review each arm or cohort in the study, along with the interventions and objectives associated with them.
Group R
Rapid Prototyping method of fabrication of complete denture: the master casts will be scanned using DENTAL WINGS eco-scan 3, using laser technology for scanning, after spraying the stainless steel pins with scanning spray to be recorded into the denture base. Virtual model will be obtained for fabrication of denture bases. Denture base will be designed and modified on the virtual model, then it will be printed using ZENITH-3D Printer using Urethane acrylate oligomer based photo-polymerized resin.
Rapid Prototyping method of fabrication of complete denture
For Rapid Prototyping Method of fabrication of complete denture : the master casts will be scanned using DENTAL WINGS eco-scan 3, using laser technology for scanning, after spraying the stainless steel pins with scanning spray to be recorded into the denture base. Virtual model will be obtained for fabrication of denture bases. Denture base will be designed and modified on the virtual model, then it will be printed using ZENITH-3D Printer using Urethane acrylate oligomer based photo-polymerized resin.
Group C
Conventional method of fabrication of complete denture: Self-cured acrylic resin trial denture bases will be constructed on the obtained master casts, then processing of the final denture bases by conventional clamping method cured by long curing cycle (74º C for 8 hours) using heat-cured poly-methyl methacrylate (PMMA) resin material. The position of the pins will be recorded into the denture bases so that the linear changes could be measured.
Conventional method of fabrication of complete denture
For Conventional Method of fabrication of complete denture: Self-cured acrylic resin trial denture bases will be constructed on the obtained master casts, then processing of the final denture bases by conventional clamping method cured by long curing cycle (74º C for 8 hours) using heat-cured poly-methyl methacrylate (PMMA) resin material. The position of the pins will be recorded into the denture bases so that the linear changes could be measured.
Interventions
Learn about the drugs, procedures, or behavioral strategies being tested and how they are applied within this trial.
Rapid Prototyping method of fabrication of complete denture
For Rapid Prototyping Method of fabrication of complete denture : the master casts will be scanned using DENTAL WINGS eco-scan 3, using laser technology for scanning, after spraying the stainless steel pins with scanning spray to be recorded into the denture base. Virtual model will be obtained for fabrication of denture bases. Denture base will be designed and modified on the virtual model, then it will be printed using ZENITH-3D Printer using Urethane acrylate oligomer based photo-polymerized resin.
Conventional method of fabrication of complete denture
For Conventional Method of fabrication of complete denture: Self-cured acrylic resin trial denture bases will be constructed on the obtained master casts, then processing of the final denture bases by conventional clamping method cured by long curing cycle (74º C for 8 hours) using heat-cured poly-methyl methacrylate (PMMA) resin material. The position of the pins will be recorded into the denture bases so that the linear changes could be measured.
Eligibility Criteria
Check the participation requirements, including inclusion and exclusion rules, age limits, and whether healthy volunteers are accepted.
Inclusion Criteria
* Class I Angle's ridge relationship.
* Literate patients are able to understand and respond to a written questionnaire in Arabic.
* Cooperative patients with no history psychological diseases.
* A period of at least six months should elapse from the last extraction.
Exclusion Criteria
* Patients with debilitating systemic diseases.
* Patients with xerostomia.
* Patients with temporo-mandibular joint disorders or systemic or neuromuscular disorder that might affect chewing efficiency of masticatory muscles.
* Patients with macroglossia or microstomia
* Patients with flabby and flat ridges.
* Patients with allergy to acrylic resin
40 Years
70 Years
ALL
Yes
Sponsors
Meet the organizations funding or collaborating on the study and learn about their roles.
Cairo University
OTHER
Responsible Party
Identify the individual or organization who holds primary responsibility for the study information submitted to regulators.
Tarek Salah Hashim Ali
principle investigator
Other Identifiers
Review additional registry numbers or institutional identifiers associated with this trial.
8790
Identifier Type: -
Identifier Source: org_study_id
More Related Trials
Additional clinical trials that may be relevant based on similarity analysis.