Non-invasive Brain Stimulation for Pediatric ADHD

NCT ID: NCT03104972

Last Updated: 2023-10-31

Study Results

Results pending

The study team has not published outcome measurements, participant flow, or safety data for this trial yet. Check back later for updates.

Basic Information

Get a concise snapshot of the trial, including recruitment status, study phase, enrollment targets, and key timeline milestones.

Recruitment Status

COMPLETED

Clinical Phase

NA

Total Enrollment

47 participants

Study Classification

INTERVENTIONAL

Study Start Date

2018-02-01

Study Completion Date

2022-01-30

Brief Summary

Review the sponsor-provided synopsis that highlights what the study is about and why it is being conducted.

The possibility of influencing brain activity and steadily enhancing behavioral performance through external intervention has long fascinated neuroscientists. One of these techniques, transcranial electrical stimulation (tES), has received great interest. Transcranial electrical stimulation (tES) in the current research includes two types of stimulation: transcranial direct current stimulation (tDCS) and transcranial random noise stimulation (tRNS).

The tES techniques involve the application of constant weak direct current (e.g. 1-2 mA) to the brain via skin-electrode interface, creating electric field that modulates neuronal activity. The safety profile of tES is excellent.

Despite effective pharmacotherapy for ADHD there is a need for improvement of cognitive dysfunction and behavioral symptoms that are only inadequately covered by pharmacological or psycho-social interventions. Since ADHD is the most common neurodevelopmental disorder in childhood with significant negative lifetime outcomes, non-invasive brain stimulation methods have been investigated in childhood and adolescents neuropsychiatric disorders showing promising results.

If tES is significantly effective for certain symptoms of ADHD, it may offer many advantages as a therapy. Treatment of ADHD with non-invasive brain stimulation has recently been reviewed in the medical literature, concluding that this technique seems to have efficacy in ADHD, however, standardized study protocols are needed to determine it.

In this study we intend to further examine the efficacy of tDCS and tRNS for children with ADHD and its effect on ADHD symptoms, memory, executive functions, in a randomized controlled crossover study.

Detailed Description

Dive into the extended narrative that explains the scientific background, objectives, and procedures in greater depth.

External influences on neuroplastic processes may be used for functional improvement of diseases, in particular for improving cortical functions. The possibility of influencing brain activity and steadily enhancing behavioral performance through external intervention has long fascinated neuroscientists. One of these techniques, transcranial electrical stimulation (tES), has received great interest because it has great potential use in basic research and clinical applications. Transcranial electrical stimulation (tES) in the current research includes two types of stimulation: transcranial direct current stimulation (tDCS) and transcranial random noise stimulation (tRNS). The tES techniques involve the application of constant weak direct current (e.g. 1-2 mA) to the brain via skin-electrode interface, creating electric field that modulates neuronal activity. This modulation is polarity dependent toward depolarization after anodal stimulation (excitatory) and toward hyperpolarization after cathodal stimulation (inhibitory), leading to transient changes in the resting membrane potential. The cumulative effect of longer stimulation results in a polarity-dependent facilitation or inhibition of the spontaneous neuronal firing rate and is considered neuromodulatory.

tDCS, provokes a sub-threshold modulation of neuronal excitability without depolarizing action potentials5. Post stimulation effects of tDCS depends on the duration of stimulation (lasting from several minutes up to hours) and can be found in the areas under the electrodes and also remote by network changes.

The mechanism by which tRNS influences brain activity differs from tDCS. The delivery of tRNS uses the same equipment as for tDCS. In tRNS, however, both electrodes can be used to stimulate either in homologous locations bilaterally or at different regions simultaneously. tRNS can be used to stimulate a region with a current that varies randomly in time. Such stimulation can induce excitability that lasts up to 60 minutes per 10 minutes of stimulation1. The most beneficial type of tRNS is at high-frequency (100-640Hz).

This is a randomized, double blinded, placebo-controlled, crossover study in ADHD children. Eligible participants will be randomized into the 3 following groups:

1. tDCS-placebo (sham) group to receive either tDCS or matching placebo (sham( during 5 following days (one session each day). After a one week break, there will be a crossover between the control group and the sham group: those we received tDCS in the 1st week will get sham, while those who received sham in the 1st week will received tDCS at the 3rd week.
2. tRNS-sham group, who will receive the same type of intervention with the same intervals as above but with tRNS instead of tDCS.
3. tDCS-tRNS group. Here the same intervention as above will be provided with the same intervals, but real tDCS and real tRNS will be provided in a counterbalanced fashion. This would allow to compare the different treatment in a within-subject design, as well as to compare the effect of those to sham stimulation in the first two groups in a between-subject design.

The total duration of subject participation will be 4 weeks. The study is conducted in the ADHD clinic of the Neuro-Cognitive Centre, at Hadassah-Hebrew University Medical Center.

tDCS: Stimulation would be applied using semi-dry 5X5 cm electrodes. The current would be 0.75mA, which based on previous computational modeling of tDCS in children and is estimated to equal that of 1-1.5 mA in adults. This decision was made after considering the parameters that would influence current distribution and density at the site of stimulation such as thinner scalp, less cerebrospinal fluid, and smaller head size of the paediatric population. A similar dosage using tDCS was well tolerated by children, and was not associated with adverse effects29. The anodal electrode will be positioned above the dlPFC (F3 based on the International 10-20 system, while the cathodal electrode would be placed over the right supraorbital. tRNS: Children in the active tRNS group will received 0.75mA of tRNS (100-640Hz) to their left dorsolateral prefrontal cortex (dlPFC) and the right inferior frontal gyrus (IFG) via semi-dry 5cm X 5cm electrodes, attached under designated electrode positions (F3, F8) of a tES cap that followed the International 10-20 system (InnoSphere Inc., Haifa). The left dlPFC and right IFG were chosen, based on their contribution in executive control and inhibition. tRNS will be applied for 20 minutes per session during an iPad cognitive training. Similar duration has also been used in paediatrics using tDCS29. Similar to a previous tRNS study in children, and the rational provided for tDCS we will apply 0.75mA.

Sham: For sham-tRNS we will use the same montage as in active tRNS. For sham-tDCS we will use the same montage as in active tDCS. The only difference between active and sham tES would be that in the case of the sham tES the 30 sec of ramp up of the current from 0 to 0.75mA would not be followed by 19 min of stimulation at 0.75mA as in active tES, but would immediately be followed by 30 sec ramp down period to 0mA. Such method has been shown to provide effective blindness of the stimulation condition as both active and sham tES would lead to slight itching sensation that would disappear due scalp habitation. No further stimulation would be provided in the sham group during the daily session.

The study will include 60 boys aged 7 to 12 years. The participants will be recruited among children referred to the clinic by pediatricians, general practitioners, teachers, psychologists or parents.

Conditions

See the medical conditions and disease areas that this research is targeting or investigating.

ADHD

Study Design

Understand how the trial is structured, including allocation methods, masking strategies, primary purpose, and other design elements.

Allocation Method

RANDOMIZED

Intervention Model

CROSSOVER

'tDCS-tRNS' arm: a randomized controlled crossover study. 'tRNS-Sham' arm: a randomized controlled trial
Primary Study Purpose

TREATMENT

Blinding Strategy

SINGLE

Participants

Study Groups

Review each arm or cohort in the study, along with the interventions and objectives associated with them.

tDCS - placebo

tDCS-placebo (sham) group to receive either transcranial direct stimulation (tDCS) or matching placebo (sham( during 5 following days (one session each day). After a one week break, there will be a crossover between the control group and the sham group: those we received tDCS in the 1st week will get sham, while those who received sham in the 1st week will received tDCS at the 3rd week.

Group Type EXPERIMENTAL

tDCS

Intervention Type DEVICE

Stimulation would be applied using semi-dry 5X5 cm electrodes. The current would be 0.75mA, which based on previous computational modeling of tDCS in children and is estimated to equal that of 1-1.5 mA in adults. This decision was made after considering the parameters that would influence current distribution and density at the site of stimulation such as thinner scalp, less cerebrospinal fluid, and smaller head size of the paediatric population. A similar dosage using tDCS was well tolerated by children, and was not associated with adverse effects29. The anodal electrode will be positioned above the dlPFC (F3 based on the International 10-20 system, while the cathodal electrode would be placed over the right supraorbital.

sham

Intervention Type DEVICE

For sham-tRNS we will use the same montage as in active tRNS. For sham-tDCS we will use the same montage as in active tDCS. The only difference between active and sham tES would be that in the case of the sham tES the 30 sec of ramp up of the current from 0 to 0.75mA would not be followed by 19 min of stimulation at 0.75mA as in active tES, but would immediately be followed by 30 sec ramp down period to 0mA. Such method has been shown to provide effective blindness of the stimulation condition as both active and sham tES would lead to slight itching sensation that would disappear due scalp habitation. No further stimulation would be provided in the sham group during the daily session.

tRNS - placebo

trans cranial random stimulation (tRNS)-sham group, who will receive the same type of intervention with the same intervals as above but with tRNS instead of tDCS.

Group Type EXPERIMENTAL

tRNS

Intervention Type DEVICE

Children in the active tRNS group will received 0.75mA of tRNS (100-640Hz) to their left dorsolateral prefrontal cortex (dlPFC) and the right inferior frontal gyrus (IFG) via semi-dry 5cm X 5cm electrodes, attached under designated electrode positions (F3, F8) of a tES cap that followed the International 10-20 system (InnoSphere Inc., Haifa). The left dlPFC and right IFG were chosen, based on their contribution in executive control and inhibition. tRNS will be applied for 20 minutes per session during an iPad cognitive training. Similar duration has also been used in paediatrics using tDCS29. Similar to a previous tRNS study in children, and the rational provided for tDCS we will apply 0.75mA.

sham

Intervention Type DEVICE

For sham-tRNS we will use the same montage as in active tRNS. For sham-tDCS we will use the same montage as in active tDCS. The only difference between active and sham tES would be that in the case of the sham tES the 30 sec of ramp up of the current from 0 to 0.75mA would not be followed by 19 min of stimulation at 0.75mA as in active tES, but would immediately be followed by 30 sec ramp down period to 0mA. Such method has been shown to provide effective blindness of the stimulation condition as both active and sham tES would lead to slight itching sensation that would disappear due scalp habitation. No further stimulation would be provided in the sham group during the daily session.

tDCS-tRNS

tDCS-tRNS group. Here the same intervention as above will be provided with the same intervals, but real tDCS and real tRNS will be provided in a counterbalanced fashion. This would allow to compare the different treatment in a within-subject design, as well as to compare the effect of those to sham stimulation in the first two groups in a between-subject design.

Group Type EXPERIMENTAL

tDCS

Intervention Type DEVICE

Stimulation would be applied using semi-dry 5X5 cm electrodes. The current would be 0.75mA, which based on previous computational modeling of tDCS in children and is estimated to equal that of 1-1.5 mA in adults. This decision was made after considering the parameters that would influence current distribution and density at the site of stimulation such as thinner scalp, less cerebrospinal fluid, and smaller head size of the paediatric population. A similar dosage using tDCS was well tolerated by children, and was not associated with adverse effects29. The anodal electrode will be positioned above the dlPFC (F3 based on the International 10-20 system, while the cathodal electrode would be placed over the right supraorbital.

tRNS

Intervention Type DEVICE

Children in the active tRNS group will received 0.75mA of tRNS (100-640Hz) to their left dorsolateral prefrontal cortex (dlPFC) and the right inferior frontal gyrus (IFG) via semi-dry 5cm X 5cm electrodes, attached under designated electrode positions (F3, F8) of a tES cap that followed the International 10-20 system (InnoSphere Inc., Haifa). The left dlPFC and right IFG were chosen, based on their contribution in executive control and inhibition. tRNS will be applied for 20 minutes per session during an iPad cognitive training. Similar duration has also been used in paediatrics using tDCS29. Similar to a previous tRNS study in children, and the rational provided for tDCS we will apply 0.75mA.

Interventions

Learn about the drugs, procedures, or behavioral strategies being tested and how they are applied within this trial.

tDCS

Stimulation would be applied using semi-dry 5X5 cm electrodes. The current would be 0.75mA, which based on previous computational modeling of tDCS in children and is estimated to equal that of 1-1.5 mA in adults. This decision was made after considering the parameters that would influence current distribution and density at the site of stimulation such as thinner scalp, less cerebrospinal fluid, and smaller head size of the paediatric population. A similar dosage using tDCS was well tolerated by children, and was not associated with adverse effects29. The anodal electrode will be positioned above the dlPFC (F3 based on the International 10-20 system, while the cathodal electrode would be placed over the right supraorbital.

Intervention Type DEVICE

tRNS

Children in the active tRNS group will received 0.75mA of tRNS (100-640Hz) to their left dorsolateral prefrontal cortex (dlPFC) and the right inferior frontal gyrus (IFG) via semi-dry 5cm X 5cm electrodes, attached under designated electrode positions (F3, F8) of a tES cap that followed the International 10-20 system (InnoSphere Inc., Haifa). The left dlPFC and right IFG were chosen, based on their contribution in executive control and inhibition. tRNS will be applied for 20 minutes per session during an iPad cognitive training. Similar duration has also been used in paediatrics using tDCS29. Similar to a previous tRNS study in children, and the rational provided for tDCS we will apply 0.75mA.

Intervention Type DEVICE

sham

For sham-tRNS we will use the same montage as in active tRNS. For sham-tDCS we will use the same montage as in active tDCS. The only difference between active and sham tES would be that in the case of the sham tES the 30 sec of ramp up of the current from 0 to 0.75mA would not be followed by 19 min of stimulation at 0.75mA as in active tES, but would immediately be followed by 30 sec ramp down period to 0mA. Such method has been shown to provide effective blindness of the stimulation condition as both active and sham tES would lead to slight itching sensation that would disappear due scalp habitation. No further stimulation would be provided in the sham group during the daily session.

Intervention Type DEVICE

Eligibility Criteria

Check the participation requirements, including inclusion and exclusion rules, age limits, and whether healthy volunteers are accepted.

Inclusion Criteria

1. Meet ADHD criteria according to the DSM-5
2. Meet ADHD criteria according to "gold standard" AAP criteria = semi-structured interview, medical/neurological examination
3. Score above the standard clinical cut off values for ADHD symptoms on ADHD-RS
4. Drug naïve. -

Exclusion Criteria

1. Chronic neurological disease
2. Epilepsy in subject or first degree relative
3. Intellectual disability
4. Any other chronic conditions
5. Chronic use of medications
6. Other primary psychiatric diagnosis (e.g., depression, anxiety, psychosis) -
Minimum Eligible Age

6 Years

Maximum Eligible Age

12 Years

Eligible Sex

ALL

Accepts Healthy Volunteers

No

Sponsors

Meet the organizations funding or collaborating on the study and learn about their roles.

Hebrew University of Jerusalem

OTHER

Sponsor Role lead

Responsible Party

Identify the individual or organization who holds primary responsibility for the study information submitted to regulators.

Mor Nahum

Computerized Neurotherapy Lab

Responsibility Role PRINCIPAL_INVESTIGATOR

Locations

Explore where the study is taking place and check the recruitment status at each participating site.

Computerized Neurotherapy Lab, School of OT, Hebrew University

Jerusalem, Mount Scopus, Israel

Site Status

Countries

Review the countries where the study has at least one active or historical site.

Israel

References

Explore related publications, articles, or registry entries linked to this study.

Berger I, Dakwar-Kawar O, Grossman ES, Nahum M, Cohen Kadosh R. Scaffolding the attention-deficit/hyperactivity disorder brain using transcranial direct current and random noise stimulation: A randomized controlled trial. Clin Neurophysiol. 2021 Mar;132(3):699-707. doi: 10.1016/j.clinph.2021.01.005. Epub 2021 Jan 27.

Reference Type BACKGROUND
PMID: 33561725 (View on PubMed)

Dakwar-Kawar O, Berger I, Barzilay S, Grossman ES, Cohen Kadosh R, Nahum M. Examining the Effect of Transcranial Electrical Stimulation and Cognitive Training on Processing Speed in Pediatric Attention Deficit Hyperactivity Disorder: A Pilot Study. Front Hum Neurosci. 2022 Jul 27;16:791478. doi: 10.3389/fnhum.2022.791478. eCollection 2022.

Reference Type BACKGROUND
PMID: 35966992 (View on PubMed)

Study Documents

Access uploaded study-related documents such as protocols, statistical analysis plans, or lay summaries.

Document Type: similar protocol

Looi CY, Cohen Kadosh R. Brain stimulation, mathematical, and numerical training: Contribution of core and noncore skills. Prog Brain Res. 2016;227:353-88. doi: 10.1016/bs.pbr.2016.04.009.