Prospective Multicenter Registry On RadiaTion Dose Estimates Of Cardiac CT AngIOgraphy IN Daily Practice in 2017
NCT ID: NCT02996903
Last Updated: 2018-05-15
Study Results
The study team has not published outcome measurements, participant flow, or safety data for this trial yet. Check back later for updates.
Basic Information
Get a concise snapshot of the trial, including recruitment status, study phase, enrollment targets, and key timeline milestones.
COMPLETED
4502 participants
OBSERVATIONAL
2017-03-01
2017-12-31
Brief Summary
Review the sponsor-provided synopsis that highlights what the study is about and why it is being conducted.
A decade ago, the multicentre observational PROTECTION-I study has revealed that the dose-length-product of CCTA ranges between 568 - 1259 mGy x cm with a median of 885 mGy x cm. This corresponds to an estimated effective dose of approximately 12 mSv. Since then a variety of techniques have been developed and enhanced in order to reduce radiation exposure during CCTA. Recent studies demonstrated feasibility of dramatically reduced effective radiation doses during CCTA (0,1 - 0,3 mSv). This has been executed in small cohorts of patients at scientific expert centers. However, it remains unclear, if such low-level radiation dose exposure may be achieved in clinical routine and if diagnostic image quality is maintained. In order to analyze the magnitude of radiation dose exposure of CCTA in today's clinical practice and the current use of dose-saving techniques, we designed the PROTECTION-VI study. Eventually, this study may contribute to further improving radiation dose exposure for patients undergoing CCTA.
Related Clinical Trials
Explore similar clinical trials based on study characteristics and research focus.
Prospective Multicenter Registry On Radiation Dose Estimates Of Cardiac CT Angiography in Daily Practice in 2017 (PROTECTION VI)
NCT03253692
Prospective Randomized Trial On Radiation Dose Estimates Of CT Angiography In Patients Applying Iterative Image Reconstruction Techniques - The PROTECTION V Study -
NCT01453712
A Registry of Cardiac PET and CardioFlux Magnetocardiography in Patients With Suspected Coronary Ischemia.
NCT05868902
Registry for CARDIAC PERFUSION CT
NCT01346605
Personalization of CM Injection Protocols in Coronary Computed Tomographic Angiography
NCT03292354
Detailed Description
Dive into the extended narrative that explains the scientific background, objectives, and procedures in greater depth.
A decade ago, the multicentre observational PROTECTION I study has revealed that the dose-length-product of CCTA ranges between 568-1259 mGy x cm with a median of 885 mGy x cm. This corresponds to an estimated effective dose of approximately 12 mSv. Furthermore, PROTECTION I demonstrated an up to 7-fold variation of radiation dose between different study sites implicating the large potential for dose reduction. Finally, significant differences have been detected in the radiation exposures between CT systems from different vendors and application of dose-saving algorithms, implying that approaches for dose reduction with respect to hardware and software have also been of relevance in 2007.
Since then a variety of techniques have been developed and enhanced in order to reduce radiation exposure during CCTA. Earlier, ECG-controlled tube current modulation has been accepted to reduce radiation dose and was therefore used in ECG-gated retrospective cardiac spiral scanning.
Another dose-saving technique is the reduction of tube potential from conventionally 120 kVp to 100 kVp in non-obese patients. In the PROTECTION II trial we demonstrated that diagnostic image quality is being maintained with a reduction of tube potential to 100 kVp while radiation exposure was significantly reduced by 31%.
Development of prospective ECG-gated axial (sequential) scanning allowed further dose reduction, due to administration of radiation only at the end of diastole. In the PROTECTION III trial we could demonstrate that diagnostic image quality is being maintained with prospective ECG-gated axial scanning in patients with stable and low heart rates while radiation exposure was reduced by 69% when compared to conventional spiral scanning with retrospective ECG gating. Using prospectively ECG-triggered high-pitch spiral CCTA with image acquisition during only one cardiac cycle, additional dosage may be saved when used in selected patients with low and stable heart rates. However, a scan strategy with an attempt of high-pitch scanning first is vulnerable to motion artefacts and bears the risk of repeated scanning.
In the PROTECTION IV trial we compared a scan strategy of high-pitch helical scanning first with a conventional scan first strategy. We could demonstrate maintenance of image quality using the strategy of high-pitch helical scanning first, while radiation exposure was reduced by 57 %, when compared to the conventional scan first strategy.
The introduction of iterative image reconstruction technique with advanced raw data processing let to improvement of image quality compared to traditional filtered back projection. This allowed additional dose saving during image acquisition. In the PROTECTION V trial we demonstrated the feasibility of combining iterative image reconstruction techniques with a reduction of tube currents by 30% leading to maintenance of diagnostic image quality while saving radiation dose linearly to tube current.
In summary, the four randomized clinical trials PROTECTION II-V demonstrated that different techniques for reducing radiation exposure during CCTA can be applied in clinical practice without compromising diagnostic image quality. The studies show that the different approaches can also be applied in combination and that these approaches can be used with different CT platforms from different CT vendors.
Recent studies demonstrated that the effective radiation dose for one CCTA scan may be reduced to 0,3 mSv15 or even below 0,1 mSv in a small amount of carefully selected patients. However, it remains unclear if such dramatically low dosages are being achieved and if diagnostic image quality is being maintained in clinical routine. In order to analyze the magnitude of radiation dose exposure during CCTA in today's clinical practice, we designed the international and multicentric PROTECTION VI study. We will assess the variation of radiation dose with respect to vendors, CT systems and study sites. Furthermore, we will evaluate the usage of dose saving strategies including the above-mentioned in daily practice and analyze their effect on diagnostic image quality. On the basis of the collected data, we will evaluate the potential use of additional dose savings for each site individually.
Conditions
See the medical conditions and disease areas that this research is targeting or investigating.
Study Design
Understand how the trial is structured, including allocation methods, masking strategies, primary purpose, and other design elements.
OTHER
PROSPECTIVE
Eligibility Criteria
Check the participation requirements, including inclusion and exclusion rules, age limits, and whether healthy volunteers are accepted.
Inclusion Criteria
* Patients age \> 18 years
* Signed informed consent (if required by local IRB)
Exclusion Criteria
18 Years
ALL
No
Sponsors
Meet the organizations funding or collaborating on the study and learn about their roles.
LMU Klinikum
OTHER
Responsible Party
Identify the individual or organization who holds primary responsibility for the study information submitted to regulators.
Thomas Stocker
Co-Principal Investigator
Locations
Explore where the study is taking place and check the recruitment status at each participating site.
National Heart, Lung, and Blood Institute
Bethesda, Maryland, United States
University of British Columbia, Department of Medical Imaging
Vancouver, British Columbia, Canada
Ludwig-Maximilians-Universitaet Muenchen, Medizinische Klinik I
Munich, Bavaria, Germany
Technion Israel Institute of Technology, The Ruth and Bruce Rappaport Faculty of Medicine
Haifa, , Israel
Countries
Review the countries where the study has at least one active or historical site.
References
Explore related publications, articles, or registry entries linked to this study.
Stocker TJ, Leipsic J, Hadamitzky M, Chen MY, Rubinshtein R, Deseive S, Heckner M, Bax JJ, Kitagawa K, Marques H, Schmermund A, Silva C, Mahmarian J, Kang JW, Grove EL, Lesser J, Massberg S, Hausleiter J. Application of Low Tube Potentials in CCTA: Results From the PROTECTION VI Study. JACC Cardiovasc Imaging. 2020 Feb;13(2 Pt 1):425-434. doi: 10.1016/j.jcmg.2019.03.030. Epub 2019 Jun 12.
Other Identifiers
Review additional registry numbers or institutional identifiers associated with this trial.
MUC I002-16
Identifier Type: -
Identifier Source: org_study_id
More Related Trials
Additional clinical trials that may be relevant based on similarity analysis.