Safety and Effectiveness Evaluation of the ForConti Fecal Management System - Pilot Study
NCT ID: NCT02865291
Last Updated: 2018-06-25
Study Results
The study team has not published outcome measurements, participant flow, or safety data for this trial yet. Check back later for updates.
Basic Information
Get a concise snapshot of the trial, including recruitment status, study phase, enrollment targets, and key timeline milestones.
UNKNOWN
NA
20 participants
INTERVENTIONAL
2015-12-31
2018-12-31
Brief Summary
Review the sponsor-provided synopsis that highlights what the study is about and why it is being conducted.
The purpose of the study is to demonstrate that the ForConti FIMS is safe and that it improves management of fecal incontinence and improves quality of life.
Patients will record bowel events in a daily diary over a 6 week period, which includes 2 weeks without using the device followed by 4 weeks using the device. Quality of Life questionnaire will be completed before and after use of the device. Stool leakage data collected when the device is not being used will be compared with data collected during use of the device to determine effectiveness.
Related Clinical Trials
Explore similar clinical trials based on study characteristics and research focus.
Safety and Effectiveness Evaluation of the ForConti Contix Fecal Incontinence Management System (FIMS)
NCT03813251
Prospective and Comparative Evaluation of a Medical Device Composed of a Perineal Probe Connected to a Mobile Application in the Management of Stress Urinary Incontinence.
NCT06285292
Sacral Nerve Stimulation Therapy for the Treatment of Chronic Fecal Incontinence
NCT00200057
A Feasibility Study of a Fecal Incontinence Management System for Medical Use
NCT00556972
Does Percutaneous Tibial Nerve Stimulation (PTNS) Improve Outcomes in Patients Presenting With Fecal Incontinence
NCT01274585
Detailed Description
Dive into the extended narrative that explains the scientific background, objectives, and procedures in greater depth.
The main reason for pain and discomfort with the current available anal plugs is the plug location within the anus below the dentate line. This part of the anus which is highly sensitive it causes discomfort and pain to the user. The advantage of the ForConti device is that it is designed to be located at a more inner section of the anal canal, above the dentate line, which is much less sensitive thus does not cause discomfort to the user.
This is a prospective, feasibility, non-randomized, single-arm, self-controlled study for preliminary safety and effectiveness. Total duration of the study for each patient will be 8 weeks, including follow-up.
The study will be conducted on up to 20 patients suffering from accidental bowel leakage due to bowel incontinence and who meet all of the inclusion criteria and none of the exclusion criteria. Following first 5 cases, interim preliminary safety analysis was conducted and a report submitted to Ministry of Health for approval to continue the study. Approval was granted.
Primary Safety: No device related serious adverse events. Secondary Safety: Minimal rate of device or procedure related adverse events (intra and post-operative complications) in the treatment or in the follow-up periods.
Effectiveness:
Demonstrate the effectiveness of the system by:
A Relative Percentage Change in Episodes of Accidental Bowel Leakage (ABL, FI episodes) Determined by Comparing Active Weeks to Control Weeks Results as measured by Daily Diary Recordings.
Active Weeks are the 3rd and 4th week of study treatment period and the Control Weeks are the baseline 2 weeks assessment period before starting treatment.
Other Measurements:
Usability: Evaluation of SUS Scores Quality of Life: Recording and Evaluation of a validated symptom-specific Fecal Incontinence Quality of Life (FIQoL) Questionnaire Number of incontinence days while using the device during the two-week assessment period, as compared to the baseline two-week assessment period.
The ForConti FIMS includes 2 main parts: the inserted part and the insertion system. The inserted part includes a balloon and a pulling string and the insertion system includes the applicator, plunger and the inflator. The balloon is a flexible biocompatible, silicone-based, oval-shaped, furled component. It is designed to be located in the rectum by an applicator and to be filled with a pre-determined amount of air to gain its final shape. The silicone surface is equipped with silicone gags which provide better sustainability in the rectum.
Conditions
See the medical conditions and disease areas that this research is targeting or investigating.
Study Design
Understand how the trial is structured, including allocation methods, masking strategies, primary purpose, and other design elements.
NA
SINGLE_GROUP
OTHER
NONE
Study Groups
Review each arm or cohort in the study, along with the interventions and objectives associated with them.
ForConti device
Use the device up to 12 hours/day for 4 weeks
ForConti device
Interventions
Learn about the drugs, procedures, or behavioral strategies being tested and how they are applied within this trial.
ForConti device
Eligibility Criteria
Check the participation requirements, including inclusion and exclusion rules, age limits, and whether healthy volunteers are accepted.
Inclusion Criteria
2. Patient age is between 18 and 85 years old
3. History of fecal incontinence for at least 6 months
4. A minimum of four incontinence episodes during the 2-week baseline period
5. Patient colon surveillance must be in compliance with the Ministry of Health National Program American Cancer Society colon for the Early Detection of Colorectal Cancer screening guidelines.
6. Patient comprehends study meaning \& is capable of carrying out study duties.
Exclusion Criteria
2. Known life threatening disease such as cancer, immune deficiency state
3. Significant cardiac arrhythmia
4. Pregnant or Breastfeeding
5. Inflammatory bowel disease
6. Anti-coagulants and anti-platelets treatment, except Aspirin (low dose: 75-100 mg/day)
7. Anorectal diseases: perianal abscess, active fistula, fissure, hemorrhoids grade 3 or 4, Pruritus ani or rectal bleeding
8. Chronic pelvic pain
9. Rectal surgery in past 6 months
18 Years
85 Years
ALL
No
Sponsors
Meet the organizations funding or collaborating on the study and learn about their roles.
ForConti Medical
INDUSTRY
Responsible Party
Identify the individual or organization who holds primary responsibility for the study information submitted to regulators.
Principal Investigators
Learn about the lead researchers overseeing the trial and their institutional affiliations.
Mark Beer-Gabel, MD
Role:
Sheba Medical Center
Josef Lysi, MD
Role:
Shaheed Ziaur Rahman Medical College
Other Identifiers
Review additional registry numbers or institutional identifiers associated with this trial.
CD-14-001
Identifier Type: -
Identifier Source: org_study_id