Prospective, Randomized Controlled Comparison of TERUMO SurFlash Plus Versus BD Insyte Autoguard in an Urban ED

NCT ID: NCT02769442

Last Updated: 2019-11-04

Study Results

Results available

Outcome measurements, participant flow, baseline characteristics, and adverse events have been published for this study.

View full results

Basic Information

Get a concise snapshot of the trial, including recruitment status, study phase, enrollment targets, and key timeline milestones.

Recruitment Status

COMPLETED

Clinical Phase

NA

Total Enrollment

600 participants

Study Classification

INTERVENTIONAL

Study Start Date

2016-06-30

Study Completion Date

2016-10-31

Brief Summary

Review the sponsor-provided synopsis that highlights what the study is about and why it is being conducted.

A randomized prospective comparison of two FDA approved intravenous catheters in the emergency department setting. The Terumo SurFlash Plus offers novel technologies that promise to increase intravenous access success rates and decrease blood contamination of the insertion site. This study would analyze these properties in our busy, urban emergency department setting where time and safety of intravenous access are most critical.

Detailed Description

Dive into the extended narrative that explains the scientific background, objectives, and procedures in greater depth.

Rational for the Study Emergency department (ED) patients frequently require rapid, short-term intravenous (IV) access for diagnosis and treatment of emergency medical conditions. IV access can be uncomfortable and painful for the patient. Therefore ensuring first attempt success is important. Furthermore, given the time-sensitive nature of emergent medical conditions, immediate success helps to minimize delay in analgesic medication administration, resuscitation and therapeutic interventions. The process of obtaining IV access has the potential for operator exposure to blood-borne pathogens. After a tourniquet is placed on an extremity, positive venous pressure forces blood out of the catheter until a lure lock can be applied. Traditional IV catheters require the operator to kink the catheter and apply pressure to the body of the catheter to mitigate the degree of blood leakage while simultaneously connecting the lure lock. This is a complicated process that often leads to blood contamination of the insertion site, and the environment, including the potential for blood spillage on the bedding, ground or the operator. In addition to the potential for blood-born pathogen exposures, this spillage leads to further patient care delays, as it requires prompt cleaning.

Terumo Medical Corp., a leading manufacturer of medical devices, has introduced a novel IV access catheter (which is already FDA approved) with features that promise to increase first attempt success and decrease blood contamination during the insertion process. The Terumo SurFlash Plus catheter has a technology that produces a visible flash of blood at the end of the catheter when the needle is placed in the vessel and a second flash between the catheter and the needle which confirms proper catheter placement in the vein. Furthermore, this new catheter has a proprietary safety valve that minimizes the risk of blood exposure between needle removal and IV lure lock attachment.

This study would analyze these unique properties (first skin puncture success and insertion site blood contamination) in a high volume, urban emergency department where time and safety of IV access are critical.

Purpose of Study Primary Objective: Compare the rate of first-skin puncture success using the Terumo SurFlash Plus compared with the BD Insyte Autoguard.

Secondary Objective: Compare the frequency and severity of blood contamination of the insertion site between the two aforementioned devices.

Research Design This will be a prospective, randomized controlled study of the Terumo SurFlash Plus IV catheter versus the current standard ED IV catheter (BD Insyte Autoguard).

Study device: The Terumo SurFlash Plus catheter is FDA approved and already used at multiple medical centers in the United States. Gauge sizes 18, 20 and 22 will be provided by TERUMO to the ED at no cost to the hospital.

IV inserters (operators) will be Mercy Medical Center emergency department technicians, nurses and providers who routinely obtain IV access in the ED.

Conditions

See the medical conditions and disease areas that this research is targeting or investigating.

Catheters Catheterization, Peripheral

Study Design

Understand how the trial is structured, including allocation methods, masking strategies, primary purpose, and other design elements.

Allocation Method

RANDOMIZED

Intervention Model

PARALLEL

Primary Study Purpose

TREATMENT

Blinding Strategy

NONE

Study Groups

Review each arm or cohort in the study, along with the interventions and objectives associated with them.

Terumo SurFlash Plus catheter

Patients randomized to the Terumo catheter

Group Type EXPERIMENTAL

Terumo SurFlash Plus catheter

Intervention Type DEVICE

BD Insyte Autoguard catheter

Patients randomized to the BD catheter

Group Type ACTIVE_COMPARATOR

BD Insyte Autoguard catheter

Intervention Type DEVICE

Interventions

Learn about the drugs, procedures, or behavioral strategies being tested and how they are applied within this trial.

Terumo SurFlash Plus catheter

Intervention Type DEVICE

BD Insyte Autoguard catheter

Intervention Type DEVICE

Eligibility Criteria

Check the participation requirements, including inclusion and exclusion rules, age limits, and whether healthy volunteers are accepted.

Inclusion Criteria

* Adult ED patient requiring an IV for clinical care
* Hemodynamically stable: pulse \>50 and \<130, MAP\>60
* Willing to read (or be read to) the informed consent and participate in study

Exclusion Criteria

* Medically unstable
* Agitated or psychiatrically unstable
* Lacking capacity to consent, such as with altered mental status.
* Unable to speak and read English
Minimum Eligible Age

18 Years

Eligible Sex

ALL

Accepts Healthy Volunteers

No

Sponsors

Meet the organizations funding or collaborating on the study and learn about their roles.

Terumo Medical Corporation

INDUSTRY

Sponsor Role collaborator

University of Maryland, Baltimore

OTHER

Sponsor Role lead

Responsible Party

Identify the individual or organization who holds primary responsibility for the study information submitted to regulators.

Siamak Moayedi, MD

PI

Responsibility Role PRINCIPAL_INVESTIGATOR

Principal Investigators

Learn about the lead researchers overseeing the trial and their institutional affiliations.

Siamak Moayedi, MD

Role: PRINCIPAL_INVESTIGATOR

Assistant Professor

Locations

Explore where the study is taking place and check the recruitment status at each participating site.

Mercy Medical Center

Baltimore, Maryland, United States

Site Status

Countries

Review the countries where the study has at least one active or historical site.

United States

Related Links

Access external resources that provide additional context or updates about the study.

https://www.youtube.com/watch?v=5ww5tgnPuXg

Youtube video describing Terumo SurFlash Plus catheter

Other Identifiers

Review additional registry numbers or institutional identifiers associated with this trial.

HP-00068278

Identifier Type: -

Identifier Source: org_study_id