Bioimpedance Spectroscopy for the Evaluation of Heart Failure

NCT ID: NCT02764073

Last Updated: 2021-01-26

Study Results

Results pending

The study team has not published outcome measurements, participant flow, or safety data for this trial yet. Check back later for updates.

Basic Information

Get a concise snapshot of the trial, including recruitment status, study phase, enrollment targets, and key timeline milestones.

Recruitment Status

COMPLETED

Total Enrollment

150 participants

Study Classification

OBSERVATIONAL

Study Start Date

2016-05-31

Study Completion Date

2020-05-31

Brief Summary

Review the sponsor-provided synopsis that highlights what the study is about and why it is being conducted.

Despite impressive improvements in treatment strategies, heart failure (HF) morbidity and mortality remains substantially high worldwide. Pulmonary congestion is considered the leading cause for hospital admissions and death among patients with HF. Physical examination is crucial for titrating medical treatment in these patients, but despite a good specificity it is not sensitive enough to detect early elevated cardiac filling pressures.

The N-terminal pro-B-type natriuretic peptide (NT-proBNP) is a recognized powerful predictor for HF prognosis. Recently, cardiotrophin-1 and galectin-3 have been proposed as new relevant biomarkers for HF evaluation.

Echocardiography can be also used to noninvasively measure left ventricular filling pressures. Lung ultrasound (LUS) through interstitial B-line evaluation has been recently proposed as a bed-side, noninvasive tool to assess interstitial lung water. B-lines correlate with NT-proBNP and E/e' levels in patients with acute dyspnea, chronic HF or after a stress test. LUS can also identify clinically silent pulmonary edema, suggesting that it may complement clinical evaluation to improve hemodynamic profiling and treatment optimization.

Biompedance is a bedside method for total body fluid status assessment. It defines individual fluid status/compartments/overload on the basis of an individual's normal extracellular volume and body composition. Recent studies indicate that bioimpedance-derived fluid overload indices are independent predictors of mortality in renal failure patients.

To date, no study has evaluated bioimpedance performance for fluid assessment in HF patients. The investigators aim to cross-sectionally compare bioimpedance parameters with clinical evaluation, LUS, cardiac biomarkers, and echocardiographic characteristics, in a cohort of incident consecutive patients with HF. Two years patients' survival will be evaluated to propose the best evaluative algorithm and rank the various methods for prognostic significance.

Detailed Description

Dive into the extended narrative that explains the scientific background, objectives, and procedures in greater depth.

Conditions

See the medical conditions and disease areas that this research is targeting or investigating.

Heart Failure

Study Design

Understand how the trial is structured, including allocation methods, masking strategies, primary purpose, and other design elements.

Observational Model Type

COHORT

Study Time Perspective

PROSPECTIVE

Interventions

Learn about the drugs, procedures, or behavioral strategies being tested and how they are applied within this trial.

Bioimpedance spectroscopy

The technique involves attaching electrodes to the patient's forearm and ipsilateral ankle, with the patient in a supine position. The BCM® measures the body resistance and reactance to electrical currents of 50 discrete frequencies, ranging between 5 and 1000 kHz. Based on a fluid model using these resistances, the extracellular water (ECW), the intracellular water (ICW) and the total body water (TBW) are calculated. All calculations are automatically performed by the software of the BCM® device. Absolute fluid overload (AFO) is is defined as the difference between the expected patient's ECW under normal physiological conditions and the actual ECW, whereas the relative fluid overload (RFO) is defined as the absolute fluid overload AFO to ECW ratio.

Intervention Type DEVICE

Lung Ultrasonography

Examinations will be performed in the supine position. Scanning of the anterior and lateral chest will be performed on both sides of the chest, from the second to the fourth (on the right side to the fifth) intercostal spaces, at parasternal to mid-axillary lines. B-lines will be recorded in each intercostal space and were defined as a hyperechoic, coherent US bundle at narrow basis going from the transducer to the limit of the screen. B-lines starting from the pleural line can be either localized or scattered to the whole lung and be present as isolated or multiple artifacts (with a distance 7 mm between 2 artifacts). The sum of B-lines produces a score reflecting the extent of lung water accumulation (0 being no detectable B-line).

Intervention Type DEVICE

Echocardiography

All echocardiographic measurements will be carried out according to the recommendations of the American Society of Echocardiography by an observer unaware of the lung ultrasound and bioimpedance results. Echocardiographic evaluation will provide information about cardiac anatomy (e.g. volumes, geometry, mass) and function (e.g. left ventricular function and wall motion, valvular function, right ventricular function, pulmonary artery pressure, pericardium).

Intervention Type DEVICE

Other Intervention Names

Discover alternative or legacy names that may be used to describe the listed interventions across different sources.

BCM®Body Composition Monitor - Fresenius Medical Care D GmbH

Eligibility Criteria

Check the participation requirements, including inclusion and exclusion rules, age limits, and whether healthy volunteers are accepted.

Inclusion Criteria

1. age ≥18 years;
2. HF diagnosis regardless of cause as defined by the Framingham criteria and satisfying the European Society of Cardiology guidelines;

Exclusion Criteria

1. metallic joint prostheses, cardiac stent or pacemakers, decompensated cirrhosis, pregnancy and limb amputations (due to bioimpedance technique limitations);
2. no prior diagnosis of pulmonary fibrosis (due to lung ultrasonography limitations);
3. absence of congenital heart disease
Minimum Eligible Age

18 Years

Eligible Sex

ALL

Accepts Healthy Volunteers

No

Sponsors

Meet the organizations funding or collaborating on the study and learn about their roles.

Grigore T. Popa University of Medicine and Pharmacy

OTHER

Sponsor Role lead

Responsible Party

Identify the individual or organization who holds primary responsibility for the study information submitted to regulators.

Professor Adrian Covic

Professor

Responsibility Role PRINCIPAL_INVESTIGATOR

Locations

Explore where the study is taking place and check the recruitment status at each participating site.

Dr. CI Parhon

Iași, , Romania

Site Status

Countries

Review the countries where the study has at least one active or historical site.

Romania

References

Explore related publications, articles, or registry entries linked to this study.

Siriopol D, Popa R, Mihaila M, Rusu F, Sascau R, Statescu C, Catalina Z, Vasiliu V, Bucur A, Neamtu A, Siriopol I, Cianga P, Kanbay M, Covic A. Application of survival classification and regression tree analysis for identification of subgroups of risk in patients with heart failure and reduced left ventricular ejection fraction. Int J Cardiovasc Imaging. 2021 Jun;37(6):1853-1861. doi: 10.1007/s10554-021-02159-6. Epub 2021 Jan 16.

Reference Type DERIVED
PMID: 33454896 (View on PubMed)

Other Identifiers

Review additional registry numbers or institutional identifiers associated with this trial.

BIS-HF

Identifier Type: -

Identifier Source: org_study_id

More Related Trials