Double/Single Balloon Enteroscopy Stiffening Wire RCT

NCT ID: NCT02720848

Last Updated: 2023-10-05

Study Results

Results pending

The study team has not published outcome measurements, participant flow, or safety data for this trial yet. Check back later for updates.

Basic Information

Get a concise snapshot of the trial, including recruitment status, study phase, enrollment targets, and key timeline milestones.

Recruitment Status

COMPLETED

Clinical Phase

NA

Total Enrollment

54 participants

Study Classification

INTERVENTIONAL

Study Start Date

2016-07-31

Study Completion Date

2023-01-05

Brief Summary

Review the sponsor-provided synopsis that highlights what the study is about and why it is being conducted.

This is a randomized clinical trial examining the use of a stiffening wire to increase depth of maximal insertion during double and single balloon enteroscopy.

Detailed Description

Dive into the extended narrative that explains the scientific background, objectives, and procedures in greater depth.

BACKGROUND Small bowel endoscopy has undergone a paradigm shift in the past decade. Prior to this, the small bowel was considered a 'black hole' due to our inability to visualize it endoscopically and the limited sensitivity of radiologic studies. This all changed with the development of capsule endoscopy, which gave physicians the ability to visualize the full length of the small bowel. Although widely considered a great leap forward, video capsule endoscopy is limited by its inability to perform any form of endoscopic intervention. Thus, something was needed to biopsy and treat the abnormalities detected with capsule endoscopy. Double balloon enteroscopy (DBE) was invented in Japan in 2001. Using an overtube and two inflatable balloons, DBE enabled deep intubation of the small bowel through a series of push and pull maneuvers to accordion the small bowel over the overtube. This procedure proved highly successful in the diagnosis and treatment of small bowel diseases. Subsequently, single balloon enteroscopy (SBE) was developed consisting of a single overtube balloon. Collectively, these techniques are called balloon assisted enteroscopy.

Balloon assisted enteroscopy can be performed using an antegrade (through the mouth) or retrograde (through the anus) approach. The two approaches are considered complimentary since the antegrade approach enables visualization of the proximal and mid small bowel while the distal portion is seen with the retrograde approach. Complete enteroscopy, or visualization of the entire small intestine, occurs when an antegrade enteroscopy is performed and the tattoo left at the depth of maximal insertion is reached during a subsequent retrograde procedure. Although considered to be the gold standard for enteroscopy, this is rarely achieved outside of expert centres in Japan. The reason for this is because of loop formation in the small intestine, commonly referred to as looping (Figure 1). Looping typically worsens as the depth of insertion increases and eventually prevents forward migration of the enteroscope.

Looping is not unique to enteroscopy and is a common problem encountered during colonoscopy. During colonoscopy, loops can be removed, by pulling back and torqueing the colonoscope. However, the loop often reforms when the colonoscope is pushed forward again. To counter this problem, colonoscopes have been developed with adjustable stiffness that can be changed during the procedure (Olympus Inc., Tokyo, Japan). Using this feature, the loop can be removed and the colonoscope stiffened prior to pushing forward to prevent loop reformation.

Although variable stiffness is available in colonoscopes, the same technology cannot be incorporated into enteroscopes due to its much thinner diameter. Recently, an enteroscopy stiffening wire has been developed by Zutron Medical LLC (Kansas, USA). This through the scope wire can be inserted as needed to increase the stiffness of the enteroscope. In theory, this should improve the performance of DBE/SBE and translate into deeper insertion although this has never been investigated. The objective of this randomized clinical trial is to answer this question.

STUDY DESIGN

This is a single centre randomized clinical trial assessing whether a stiffening wire increases the depth of maximal insertion during DBE/SBE. Due to the nature of the procedure, blinding of the endoscopist is impossible. This is because even if a placebo wire is used, the enteroscope feels sufficiently different to enable unmasking. To mitigate the risk of bias, the enteroscopy will be recorded and outcomes assessed in a blinded fashion using the recorded video. Randomization will be in blocks of varying sizes and performed using sequentially labelled sealed envelopes.

STUDY INTERVENTION

1. After fasting overnight, sedation is given at the start of the procedure. This consists of either Propofol administered by an anesthetist or midazolam and fentanyl administered by the endoscopist.
2. The enteroscope is inserted into the mouth, down the esophagus, though the stomach, and into the duodenum.
3. Once in the small bowel, a series of push and pull maneuvers are used as previously described (1). Each set of maneuvers is called a cycle.
4. Cycles are repeated until looping prevents any further forward movement and the depth of maximal insertion is reached. In the study, depth of maximal insertion 1 will be defined as a lack of forward movement after 3 consecutive cycles.
5. When the depth of maximal insertion 1 has been reached, a small mark will be made on the wall of the small bowel by sucking mucosa into the enteroscope (ie. suction mark) or using biopsy forceps to create a 3 mm disruption in the mucosa. A virtual mark will also be made on the endoscopy video.
6. Those randomized to the stiffening wire will insert the wire and attempt to proceed deeper. The technique for each cycle is the same as in step 3 and does not change with the presence of the wire.
7. Those randomized to no stiffening wire will attempt to proceed deeper using standard technique.
8. The procedure will continue until there is no forward movement after 3 consecutive cycles. If the enteroscope was able to proceed past depth of maximal insertion 1, a suction/biopsy forceps mark will be made and a virtual mark recorded on the endoscopy video to denote depth of maximal insertion 2. If the enteroscope was not able to proceed past depth of maximal insertion 1, no further marks will be made.
9. On withdrawal of the enteroscope, care will be taken by the endoscopist to ensure any suction/biopsy forceps marks are clearly visible on the video.

Conditions

See the medical conditions and disease areas that this research is targeting or investigating.

Small Intestine Problem

Study Design

Understand how the trial is structured, including allocation methods, masking strategies, primary purpose, and other design elements.

Allocation Method

RANDOMIZED

Intervention Model

PARALLEL

Primary Study Purpose

DIAGNOSTIC

Blinding Strategy

DOUBLE

Participants Outcome Assessors

Study Groups

Review each arm or cohort in the study, along with the interventions and objectives associated with them.

Stiffening wire

A stiffening wire inserted into the instrument channel of the double/single balloon enteroscope will be used.

Group Type EXPERIMENTAL

Stiffening wire

Intervention Type DEVICE

The stiffening wire will be inserted into the double/single balloon enteroscope.

Standard technique

The double/single balloon enteroscope will be used without the stiffening wire as per standard technique.

Group Type ACTIVE_COMPARATOR

Standard technique

Intervention Type DEVICE

The double/single balloon enteroscope will be used without the stiffening wire as per standard technique.

Interventions

Learn about the drugs, procedures, or behavioral strategies being tested and how they are applied within this trial.

Stiffening wire

The stiffening wire will be inserted into the double/single balloon enteroscope.

Intervention Type DEVICE

Standard technique

The double/single balloon enteroscope will be used without the stiffening wire as per standard technique.

Intervention Type DEVICE

Eligibility Criteria

Check the participation requirements, including inclusion and exclusion rules, age limits, and whether healthy volunteers are accepted.

Inclusion Criteria

* Any patient undergoing antegrade DBE/SBE.

Exclusion Criteria

* Age \< 18
* Prior surgery involving resection of the esophagus, stomach, or small bowel
* Suspected stricture or mass in any part of the gastrointestinal tract
* Failure to obtain informed consent from the patient or substitute decision maker
* Pregnancy
Minimum Eligible Age

18 Years

Eligible Sex

ALL

Accepts Healthy Volunteers

No

Sponsors

Meet the organizations funding or collaborating on the study and learn about their roles.

London Health Sciences Centre Research Institute OR Lawson Research Institute of St. Joseph's

OTHER

Sponsor Role lead

Responsible Party

Identify the individual or organization who holds primary responsibility for the study information submitted to regulators.

Responsibility Role SPONSOR

Principal Investigators

Learn about the lead researchers overseeing the trial and their institutional affiliations.

Michael Sey, MD

Role: PRINCIPAL_INVESTIGATOR

London Health Sciences Centre

Locations

Explore where the study is taking place and check the recruitment status at each participating site.

London Health Sciences Centre

London, Ontario, Canada

Site Status

Countries

Review the countries where the study has at least one active or historical site.

Canada

References

Explore related publications, articles, or registry entries linked to this study.

Yamamoto H, Sekine Y, Sato Y, Higashizawa T, Miyata T, Iino S, Ido K, Sugano K. Total enteroscopy with a nonsurgical steerable double-balloon method. Gastrointest Endosc. 2001 Feb;53(2):216-20. doi: 10.1067/mge.2001.112181.

Reference Type BACKGROUND
PMID: 11174299 (View on PubMed)

Yamamoto H, Kita H, Sunada K, Hayashi Y, Sato H, Yano T, Iwamoto M, Sekine Y, Miyata T, Kuno A, Ajibe H, Ido K, Sugano K. Clinical outcomes of double-balloon endoscopy for the diagnosis and treatment of small-intestinal diseases. Clin Gastroenterol Hepatol. 2004 Nov;2(11):1010-6. doi: 10.1016/s1542-3565(04)00453-7.

Reference Type BACKGROUND
PMID: 15551254 (View on PubMed)

May A, Nachbar L, Ell C. Double-balloon enteroscopy (push-and-pull enteroscopy) of the small bowel: feasibility and diagnostic and therapeutic yield in patients with suspected small bowel disease. Gastrointest Endosc. 2005 Jul;62(1):62-70. doi: 10.1016/s0016-5107(05)01586-5.

Reference Type BACKGROUND
PMID: 15990821 (View on PubMed)

Hartmann D, Eickhoff A, Tamm R, Riemann JF. Balloon-assisted enteroscopy using a single-balloon technique. Endoscopy. 2007 Feb;39 Suppl 1:E276. doi: 10.1055/s-2007-966616. Epub 2007 Oct 24. No abstract available.

Reference Type BACKGROUND
PMID: 17957636 (View on PubMed)

Kawamura T, Yasuda K, Tanaka K, Uno K, Ueda M, Sanada K, Nakajima M. Clinical evaluation of a newly developed single-balloon enteroscope. Gastrointest Endosc. 2008 Dec;68(6):1112-6. doi: 10.1016/j.gie.2008.03.1063. Epub 2008 Jul 2.

Reference Type BACKGROUND
PMID: 18599052 (View on PubMed)

Domagk D, Mensink P, Aktas H, Lenz P, Meister T, Luegering A, Ullerich H, Aabakken L, Heinecke A, Domschke W, Kuipers E, Bretthauer M. Single- vs. double-balloon enteroscopy in small-bowel diagnostics: a randomized multicenter trial. Endoscopy. 2011 Jun;43(6):472-6. doi: 10.1055/s-0030-1256247. Epub 2011 Mar 7.

Reference Type BACKGROUND
PMID: 21384320 (View on PubMed)

Efthymiou M, Desmond PV, Brown G, La Nauze R, Kaffes A, Chua TJ, Taylor AC. SINGLE-01: a randomized, controlled trial comparing the efficacy and depth of insertion of single- and double-balloon enteroscopy by using a novel method to determine insertion depth. Gastrointest Endosc. 2012 Nov;76(5):972-80. doi: 10.1016/j.gie.2012.06.033. Epub 2012 Sep 12.

Reference Type BACKGROUND
PMID: 22980289 (View on PubMed)

May A, Farber M, Aschmoneit I, Pohl J, Manner H, Lotterer E, Moschler O, Kunz J, Gossner L, Monkemuller K, Ell C. Prospective multicenter trial comparing push-and-pull enteroscopy with the single- and double-balloon techniques in patients with small-bowel disorders. Am J Gastroenterol. 2010 Mar;105(3):575-81. doi: 10.1038/ajg.2009.712. Epub 2010 Jan 5.

Reference Type BACKGROUND
PMID: 20051942 (View on PubMed)

Takano N, Yamada A, Watabe H, Togo G, Yamaji Y, Yoshida H, Kawabe T, Omata M, Koike K. Single-balloon versus double-balloon endoscopy for achieving total enteroscopy: a randomized, controlled trial. Gastrointest Endosc. 2011 Apr;73(4):734-9. doi: 10.1016/j.gie.2010.10.047. Epub 2011 Jan 26.

Reference Type BACKGROUND
PMID: 21272875 (View on PubMed)

Yamamoto H, Kita H. Enteroscopy. J Gastroenterol. 2005 Jun;40(6):555-62. doi: 10.1007/s00535-005-1645-5.

Reference Type BACKGROUND
PMID: 16007388 (View on PubMed)

Archer M, Liu E, McDonald C, Yan B, Jairath V, Sey M. A randomized controlled trial of a through-the-scope stiffening wire to increase the depth of insertion during double-balloon enteroscopy. Gastrointest Endosc. 2025 Jun;101(6):1197-1200. doi: 10.1016/j.gie.2024.11.037. Epub 2024 Nov 26.

Reference Type DERIVED
PMID: 39608590 (View on PubMed)

Other Identifiers

Review additional registry numbers or institutional identifiers associated with this trial.

107609

Identifier Type: -

Identifier Source: org_study_id

More Related Trials

Additional clinical trials that may be relevant based on similarity analysis.

Drug Coated Balloons for Prevention of Restenosis
NCT00696956 UNKNOWN PHASE2/PHASE3