Drug-coated Balloon Versus Conventional Balloon Angioplasty in Hemodialysis Graft
NCT ID: NCT02706444
Last Updated: 2016-03-11
Study Results
The study team has not published outcome measurements, participant flow, or safety data for this trial yet. Check back later for updates.
Basic Information
Get a concise snapshot of the trial, including recruitment status, study phase, enrollment targets, and key timeline milestones.
UNKNOWN
PHASE4
190 participants
INTERVENTIONAL
2016-03-31
2018-02-28
Brief Summary
Review the sponsor-provided synopsis that highlights what the study is about and why it is being conducted.
Related Clinical Trials
Explore similar clinical trials based on study characteristics and research focus.
Peripheral Scoring Drug-coated Balloon in the Treatment of Hemodialysis Arteriovenous Fistula Stenosis
NCT06422845
DCB for Dialysis Access Stent Graft Restenosis
NCT03360279
Prospective Randomized Trial Comparing DEB Versus Conventional PTA for the Treatment of Hemodialysis AVF or AVG Stenoses
NCT01544907
DRug-coAted Balloon Compared With cuttinG balloON in Treatment of Arteriovenous Fistula Stenosis
NCT06527963
Drug Coated Balloons vs Plain Balloons for the Management of Dysfunctional Dialysis Fistula
NCT03189667
Detailed Description
Dive into the extended narrative that explains the scientific background, objectives, and procedures in greater depth.
1. Pretreatment evaluation 1.1 All procedures will be performed after obtaining written informed consent from patients. No specific pre-treatment regimen will be needed.
1.2 After sterile preparation and draping, percutaneous access will be gained in an appropriately chosen hemodialysis graft after application of local anesthesia. Diagnostic fistulogram was performed to identify and evaluate the target lesion and any possible secondary lesions. In case of thrombotic occlusion of AVG, diagnostic fistulogram will be done after successful aspiration thrombectomy though a sheath.
1.3 All lesions were characterized by location, length, and degree of stenosis. The degree of stenoses was evaluated in two orthogonal planes, and the greatest degree of stenoses was used for subsequent anatomic measurements. Anatomic measurements were made with use of a calibrated reference marker or software within the angiographic imaging system. The reference vessel was defined as an adjacent segment of normal vein or graft located adjacent to the target lesion. The degree of stenosis was reported as the maximum diameter reduction compared with the reference vessel diameter.
2. PTA in venous anastomosis of AVG 2.1 Vascular sheaths will be used in all cases. 2.2 Balloon diameter will be chosen at the operator's discretion, generally starting with a balloon 10% oversized compared with the adjacent normal vein or graft in both groups (Reference Vessel Diameter: RVD).
2.3 Balloon length will be also chosen at the discretion of the operator: In general, 4-cm- or 6cm-long balloons can be used for some long lesions.
2.4 If patient requested the sedation, conscious sedation can be done. 2.5 After crossing the stenosis with a guide wire, the conventional balloon catheter was appropriately positioned across the lesion under fluoroscopic guidance. With the use of an inflation device with a pressure gauge, the balloon catheter was gradually inflated until the stenosis was eliminated.
2.6 Randomization will be assigned after successful conventional balloon angioplasty in venous anastomotic stenosis of AVG. After conventional angioplasty, patients will be randomly assigned to undergo DEB angioplasty or to receive conventional balloon angioplasty for 3 minutes (upto norminal pressure).
2.7 If the patient will be randomly assigned to the DEB group, an In.Pact® Drug-eluting balloon catheter (6, 7mm in diameter, ≦6cm in length) will be used in addition to conventional balloon angioplasty. A balloon diameter and length will be equal to that used in the conventional balloon angioplasty group.
3. Procedure Materials PRODUCT SIZE LENGTHS Drug Eluting balloon In.Pact® 6,7mm 4, 6cm Conventional balloon Various conventional balloon catheter 6,7mm 4, 6cm
4. Follow-up
* All patients will be followed after PTA. When patients visit hemodialysis unit 3 and 6 months after PTA, the patient's record will be updated.
* All patients that visit hemodialysis unit will be brought to angiographic suit to undergo follow-up fistulogram and evaluate the re-stenosis.
* Clinical follow-up will be performed in hemodialysis unit, including checking the status of hemodialysis using a those circuits and general work-up.
Conditions
See the medical conditions and disease areas that this research is targeting or investigating.
Study Design
Understand how the trial is structured, including allocation methods, masking strategies, primary purpose, and other design elements.
RANDOMIZED
PARALLEL
TREATMENT
NONE
Study Groups
Review each arm or cohort in the study, along with the interventions and objectives associated with them.
Conventional Balloon Angioplasty
Conventional balloon angioplasty. After fistulogram, full expansion of conventional balloon catheter under fluoroscopy guidance in \> 50% venous anastomotic stenosis of hemodialysis graft and ≦4cm from venous anastomosis site in lesion length, confirmed by fistulogram
Conventional Balloon angioplasty
After fistulogram, full expansion of drug-coated balloon catheter under fluoroscopy guidance in \> 50% venous anastomotic stenosis of hemodialysis graft and ≦4cm from venous anastomosis site in lesion length, confirmed by fistulogram. Then, participants were divided into two groups (Conventional balloon angioplasty or Drug-coated balloon angioplasty)
Drug-Coated Balloon Angioplasty
Drug-coated balloon angioplasty. After fistulogram, full expansion of drug-coated balloon catheter under fluoroscopy guidance in \> 50% venous anastomotic stenosis of hemodialysis graft and ≦4cm from venous anastomosis site in lesion length, confirmed by fistulogram
Drug-coated Balloon angioplasty
After fistulogram, full expansion of drug-coated balloon catheter under fluoroscopy guidance in \> 50% venous anastomotic stenosis of hemodialysis graft and ≦4cm from venous anastomosis site in lesion length, confirmed by fistulogram. Then, participants were divided into two groups (Conventional balloon angioplasty or Drug-coated balloon angioplasty)
Interventions
Learn about the drugs, procedures, or behavioral strategies being tested and how they are applied within this trial.
Conventional Balloon angioplasty
After fistulogram, full expansion of drug-coated balloon catheter under fluoroscopy guidance in \> 50% venous anastomotic stenosis of hemodialysis graft and ≦4cm from venous anastomosis site in lesion length, confirmed by fistulogram. Then, participants were divided into two groups (Conventional balloon angioplasty or Drug-coated balloon angioplasty)
Drug-coated Balloon angioplasty
After fistulogram, full expansion of drug-coated balloon catheter under fluoroscopy guidance in \> 50% venous anastomotic stenosis of hemodialysis graft and ≦4cm from venous anastomosis site in lesion length, confirmed by fistulogram. Then, participants were divided into two groups (Conventional balloon angioplasty or Drug-coated balloon angioplasty)
Eligibility Criteria
Check the participation requirements, including inclusion and exclusion rules, age limits, and whether healthy volunteers are accepted.
Inclusion Criteria
2. Hemodialysis patients with AVG in their arms: Graft should be implanted 30 days ago before enrollment
3. Vascular access actively used for hemodialysis: At least one hemodialysis successful session before enrollment.
4. Clinical signs of access dysfunction: decreased thrill, increased pulsatility, development collateral veins, limb swelling, difficulty in cannulation, prolonged bleeding after hemodialysis, high venous pressure or decreased hemodialysis flow rate during hemodialysis.
5. \> 50% venous anastomotic stenosis of AVG, confirmed by fistulogram (angiography).
6. ≦ 4cm from venous anastomosis site in lesion length
7. Reference diameter \< 7mm of non-stenotic vessel or graft adjacent to venous stenosis.
8. Full expansion of conventional balloon during primary balloon angioplasty, confirmed by fluoroscopy.
Exclusion Criteria
2. Patient unable to abide with study follow-up protocol.
3. Patient participating in other relevant or conflicting studies
4. Bare metal stent or stent-graft placed previously
5. Hemodynamically significant stenosis of the central venous system
6. ≧50% stenosis in arterial anastomotic site or venous outflow tract, non including venous anastomosis site
7. Stenosis with a corresponding thrombosis treated within 7 days before enrollment.
8. Limited life expectancy less than 6 months
9. Sepsis or active infection.
10. Recent arm thrombophlebitis (\< 6months).
11. Allergy or other known contraindication to iodinated contrast media, heparin, or paclitaxel
12. Pregnancy or Nursing state
19 Years
ALL
No
Sponsors
Meet the organizations funding or collaborating on the study and learn about their roles.
Konkuk University Medical Center
OTHER
Responsible Party
Identify the individual or organization who holds primary responsibility for the study information submitted to regulators.
Sang Woo Park
Professor
Other Identifiers
Review additional registry numbers or institutional identifiers associated with this trial.
KUH1140101
Identifier Type: -
Identifier Source: org_study_id