Clinical Data Validation of Novel Wireless Cortrium C3 Monitor for Continuous Electrocardiogram Measurements

NCT ID: NCT02714907

Last Updated: 2020-01-27

Study Results

Results pending

The study team has not published outcome measurements, participant flow, or safety data for this trial yet. Check back later for updates.

Basic Information

Get a concise snapshot of the trial, including recruitment status, study phase, enrollment targets, and key timeline milestones.

Recruitment Status

COMPLETED

Clinical Phase

NA

Total Enrollment

158 participants

Study Classification

INTERVENTIONAL

Study Start Date

2016-02-29

Study Completion Date

2017-07-31

Brief Summary

Review the sponsor-provided synopsis that highlights what the study is about and why it is being conducted.

The purpose of this study is to validate the quality of the ECG-signal acquired with the Cortrium C3 monitor. The intention is to evaluate whether the diagnosis of atrial fibrillation based on the ECG signal from the C3 monitor concurs with the current monitoring methods used in clinical practice.

Detailed Description

Dive into the extended narrative that explains the scientific background, objectives, and procedures in greater depth.

Development of new cost effective mobile devices and wireless technology has great potential in supervision of critically ill patients in wards as well as ambulant. Through continuous wireless monitoring in both the hospital and the patients home, detection of heart arrhythmias such as atrial fibrillation (AF) will be possible.

AF is the cause of a sizeable amount of strokes (15% of all, and more than 35% of the population over 80 years of age), which can be prevented through anticoagulation treatment if provided in time. Thus, many patients are referred to cardiologic ambulatory to be examined for AF, and are subjected to heart monitoring with a so-called Holter or event monitor. This entails the patient be equipped with several electrodes on the chest, to which leads are attached and connected to a sizable and bulky box. The patient carries this box around hanging from the shoulder, belt or something similar for one or several days. It is then required of the patient to come back and deliver the device, after which the data must be read and analysed, in order to work out a further plan for the patient. During admission, a similar system can be attached for continuous heart monitoring.

Cortrium (http://cortrium.com) has developed a wireless technology, where a small C3 monitor is attached to the chest with standard electrodes and the leads are built into the actual monitor. The quality of the signal has been tested on healthy adults, but is yet to be tested on patients suffering from arrhythmias

The purpose of this study is to validate the quality of the ECG-signal acquired with the Cortrium C3 monitor. The intention is to evaluate whether the diagnosis of atrial fibrillation based on the ECG signal from the C3 monitor concurs with the current monitoring methods used in clinical practice.

The measurements are performed on patients under investigation for AF at cardiology ambulatory Y at Frederiksberg-Bispebjerg Hospital and Aleris-Hamlet Hospital, Copenhagen. The patients are outfitted with a C3 monitor simultaneous with the use of the conventional ambulatory apparatus. This is a "Holter monitor" (Rozinn station RZ152+12 and RZ153+ from ScottCare Holter for Windows 2010 (CE0120) and "EventCare SA version" (CE0120), both bought via SEMCA Ap, Skævinge, Denmark.

Recordings with the usual apparatus are analysed in the usual fashion in the cardiology ambulatory. A copy of the recordings is registered anonymously and paired with the simultaneous recordings from the C3. The diagnosis is made by two observers, blinded to both patient identity and data source. Thus, data will not be personally identifiable. Validation is performed in collaboration with the department of cardiology.

Statistics:

With simultaneous supervision of 77 patients with increased incidence of AF it will be possible to determine whether the C3 is capable of detecting AF in at least 95% of the cases which Holter detects. Since the incidence of AF Is lower in the total patient group referred to Holter monitoring, we plan to include 150 patients to acquire the usable number of examinations.

Economic Conditions Helen Dominguez is the unfunded, and the responsible consultant of the study. Opeon Aps delivers C3 monitors for this clinical trial as well as brochure guides for patients and health care personnel. There are no economic benefits connected with the present clinical trial.

Publication of Results:

Opeon ApS (owner of Cortrium) is responsible for processing the material for publication of results in an international peer-reviewed journal as well as in the Danish popular scientific press related to new Medical equipment. Positive, negative and inconclusive results will be published.

Recruitment of Participants:

Patients who have planned ambulatory arrhythmia recording for diagnosis of intermittent AF will be asked by telephone to consider participating in the study.

After reading the participant information flyer, the subjects are invited to in-depth verbal information in the ambulatory. If the subjects accept to participate and provide a signed informed consent, they outfitted with a C3 monitor along with the standard Holter apparatus.

The study only includes subjects scheduled for Holter monitoring referred for atrial fibrillation examination, quantification of paroxysms, or heart rate during paroxysms.

Ethical Considerations:

Ethical Considerations: If the patient agrees to take part in the study, the main disadvantages are that it entails attachment of another three electrodes for the C3 monitor, increasing the risk of skin irritation, and receiving additional instructions for two devices. Since ECG recordings are non-invasive, and the C3 recordings do not result in further ambulatory visits than otherwise planned, we estimated that the strain on the patients is very limited.

The use of C3 for estimation of AF in future patients will decrease the trouble of loose leads. For this reason, using the C3 will also simplify the work of the healthcare personnel during the attachment procedure. Overall it may lead to an increase in quality as well as increase the capacity for examining cardiac arrhythmia in the cardiology ambulatory.

Conditions

See the medical conditions and disease areas that this research is targeting or investigating.

Atrial Fibrillation

Study Design

Understand how the trial is structured, including allocation methods, masking strategies, primary purpose, and other design elements.

Allocation Method

RANDOMIZED

Intervention Model

PARALLEL

Primary Study Purpose

DIAGNOSTIC

Blinding Strategy

DOUBLE

Participants Outcome Assessors

Study Groups

Review each arm or cohort in the study, along with the interventions and objectives associated with them.

AF assessed from Cortrium C3 data

Atrial fibrillation assessed from Cortrium C3 device data

Group Type EXPERIMENTAL

Cortrium C3 device

Intervention Type DEVICE

Data is read from Cortrium C3 monitor

Holter device

Intervention Type DEVICE

Date is read from Holter device

AF assessed from Holter data

Atrial fibrillation assessed from Holter data

Group Type EXPERIMENTAL

Cortrium C3 device

Intervention Type DEVICE

Data is read from Cortrium C3 monitor

Holter device

Intervention Type DEVICE

Date is read from Holter device

Interventions

Learn about the drugs, procedures, or behavioral strategies being tested and how they are applied within this trial.

Cortrium C3 device

Data is read from Cortrium C3 monitor

Intervention Type DEVICE

Holter device

Date is read from Holter device

Intervention Type DEVICE

Eligibility Criteria

Check the participation requirements, including inclusion and exclusion rules, age limits, and whether healthy volunteers are accepted.

Inclusion Criteria

* Clinical diagnosis of atrial fibrillation
* Investigation of atrial fibrillation

Exclusion Criteria

* Language difficulties
* Impaired cognitive function.
Minimum Eligible Age

18 Years

Eligible Sex

ALL

Accepts Healthy Volunteers

No

Sponsors

Meet the organizations funding or collaborating on the study and learn about their roles.

University Hospital Bispebjerg and Frederiksberg

OTHER

Sponsor Role collaborator

Aleris-Hamlet Hospitaler København

OTHER

Sponsor Role collaborator

Cortrium

INDUSTRY

Sponsor Role lead

Responsible Party

Identify the individual or organization who holds primary responsibility for the study information submitted to regulators.

Responsibility Role SPONSOR

Principal Investigators

Learn about the lead researchers overseeing the trial and their institutional affiliations.

Helena Helena, MD, PhD

Role: PRINCIPAL_INVESTIGATOR

Bispebjerg-Frederiksberg Hospitals

Locations

Explore where the study is taking place and check the recruitment status at each participating site.

Department of Cardiology, Bispebjerg-Frederiksberg Hospitals

Frederiksberg, , Denmark

Site Status

Aleris-Hamlet Private Hospital

Søborg, , Denmark

Site Status

Countries

Review the countries where the study has at least one active or historical site.

Denmark

References

Explore related publications, articles, or registry entries linked to this study.

Saito T, Tamura K, Uchida D, Saito T, Togashi M, Nitta T, Sugisaki Y. Histopathological features of the resected left atrial appendage as predictors of recurrence after surgery for atrial fibrillation in valvular heart disease. Circ J. 2007 Jan;71(1):70-8. doi: 10.1253/circj.71.70.

Reference Type BACKGROUND
PMID: 17186981 (View on PubMed)

Syed TM, Halperin JL. Left atrial appendage closure for stroke prevention in atrial fibrillation: state of the art and current challenges. Nat Clin Pract Cardiovasc Med. 2007 Aug;4(8):428-35. doi: 10.1038/ncpcardio0933.

Reference Type BACKGROUND
PMID: 17653115 (View on PubMed)

Saltman AE, Gillinov AM. Surgical approaches for atrial fibrillation. Cardiol Clin. 2009 Feb;27(1):179-88, x. doi: 10.1016/j.ccl.2008.09.012.

Reference Type BACKGROUND
PMID: 19111773 (View on PubMed)

Gillinov AM. Advances in surgical treatment of atrial fibrillation. Stroke. 2007 Feb;38(2 Suppl):618-23. doi: 10.1161/01.STR.0000247934.04848.79.

Reference Type BACKGROUND
PMID: 17261702 (View on PubMed)

Al-Saady NM, Obel OA, Camm AJ. Left atrial appendage: structure, function, and role in thromboembolism. Heart. 1999 Nov;82(5):547-54. doi: 10.1136/hrt.82.5.547.

Reference Type BACKGROUND
PMID: 10525506 (View on PubMed)

Fitzmaurice D. Atrial fibrillation and coagulation: who and when? Blood Rev. 2009 Nov;23(6):241-4. doi: 10.1016/j.blre.2009.07.006. Epub 2009 Aug 25.

Reference Type BACKGROUND
PMID: 19709791 (View on PubMed)

Furberg CD, Psaty BM, Manolio TA, Gardin JM, Smith VE, Rautaharju PM. Prevalence of atrial fibrillation in elderly subjects (the Cardiovascular Health Study). Am J Cardiol. 1994 Aug 1;74(3):236-41. doi: 10.1016/0002-9149(94)90363-8.

Reference Type BACKGROUND
PMID: 8037127 (View on PubMed)

Page RL, Wilkinson WE, Clair WK, McCarthy EA, Pritchett EL. Asymptomatic arrhythmias in patients with symptomatic paroxysmal atrial fibrillation and paroxysmal supraventricular tachycardia. Circulation. 1994 Jan;89(1):224-7. doi: 10.1161/01.cir.89.1.224.

Reference Type BACKGROUND
PMID: 8281651 (View on PubMed)

Healey JS, Connolly SJ, Gold MR, Israel CW, Van Gelder IC, Capucci A, Lau CP, Fain E, Yang S, Bailleul C, Morillo CA, Carlson M, Themeles E, Kaufman ES, Hohnloser SH; ASSERT Investigators. Subclinical atrial fibrillation and the risk of stroke. N Engl J Med. 2012 Jan 12;366(2):120-9. doi: 10.1056/NEJMoa1105575.

Reference Type BACKGROUND
PMID: 22236222 (View on PubMed)

Israel CW, Gronefeld G, Ehrlich JR, Li YG, Hohnloser SH. Long-term risk of recurrent atrial fibrillation as documented by an implantable monitoring device: implications for optimal patient care. J Am Coll Cardiol. 2004 Jan 7;43(1):47-52. doi: 10.1016/j.jacc.2003.08.027.

Reference Type BACKGROUND
PMID: 14715182 (View on PubMed)

Thakkar S, Bagarhatta R. Detection of paroxysmal atrial fibrillation or flutter in patients with acute ischemic stroke or transient ischemic attack by Holter monitoring. Indian Heart J. 2014 Mar-Apr;66(2):188-92. doi: 10.1016/j.ihj.2014.02.009. Epub 2014 Mar 4.

Reference Type BACKGROUND
PMID: 24814113 (View on PubMed)

Cotter PE, Martin PJ, Ring L, Warburton EA, Belham M, Pugh PJ. Incidence of atrial fibrillation detected by implantable loop recorders in unexplained stroke. Neurology. 2013 Apr 23;80(17):1546-50. doi: 10.1212/WNL.0b013e31828f1828. Epub 2013 Mar 27.

Reference Type BACKGROUND
PMID: 23535493 (View on PubMed)

Sanna T, Diener HC, Passman RS, Di Lazzaro V, Bernstein RA, Morillo CA, Rymer MM, Thijs V, Rogers T, Beckers F, Lindborg K, Brachmann J; CRYSTAL AF Investigators. Cryptogenic stroke and underlying atrial fibrillation. N Engl J Med. 2014 Jun 26;370(26):2478-86. doi: 10.1056/NEJMoa1313600.

Reference Type BACKGROUND
PMID: 24963567 (View on PubMed)

Fuster V, Ryden LE, Cannom DS, Crijns HJ, Curtis AB, Ellenbogen KA, Halperin JL, Le Heuzey JY, Kay GN, Lowe JE, Olsson SB, Prystowsky EN, Tamargo JL, Wann S; Task Force on Practice Guidelines, American College of Cardiology/American Heart Association; Committee for Practice Guidelines, European Society of Cardiology; European Heart Rhythm Association; Heart Rhythm Society. ACC/AHA/ESC 2006 guidelines for the management of patients with atrial fibrillation-executive summary: a report of the American College of Cardiology/American Heart Association Task Force on Practice Guidelines and the European Society of Cardiology Committee for Practice Guidelines (Writing Committee to Revise the 2001 Guidelines for the Management of Patients with Atrial Fibrillation). Eur Heart J. 2006 Aug;27(16):1979-2030. doi: 10.1093/eurheartj/ehl176. No abstract available.

Reference Type BACKGROUND
PMID: 16885201 (View on PubMed)

Lazzaro MA, Krishnan K, Prabhakaran S. Detection of atrial fibrillation with concurrent holter monitoring and continuous cardiac telemetry following ischemic stroke and transient ischemic attack. J Stroke Cerebrovasc Dis. 2012 Feb;21(2):89-93. doi: 10.1016/j.jstrokecerebrovasdis.2010.05.006. Epub 2010 Jul 24.

Reference Type BACKGROUND
PMID: 20656504 (View on PubMed)

Caldwell JC, Contractor H, Petkar S, Ali R, Clarke B, Garratt CJ, Neyses L, Mamas MA. Atrial fibrillation is under-recognized in chronic heart failure: insights from a heart failure cohort treated with cardiac resynchronization therapy. Europace. 2009 Oct;11(10):1295-300. doi: 10.1093/europace/eup201. Epub 2009 Aug 1.

Reference Type BACKGROUND
PMID: 19648586 (View on PubMed)

Nyrnes A, Mathiesen EB, Njolstad I, Wilsgaard T, Lochen ML. Palpitations are predictive of future atrial fibrillation. An 11-year follow-up of 22,815 men and women: the Tromso Study. Eur J Prev Cardiol. 2013 Oct;20(5):729-36. doi: 10.1177/2047487312446562. Epub 2012 May 15.

Reference Type BACKGROUND
PMID: 22588086 (View on PubMed)

Sulfi S, Balami D, Sekhri N, Suliman A, Kapur A, Archbold RA, Ranjadayalan K, Timmis AD. Limited clinical utility of Holter monitoring in patients with palpitations or altered consciousness: analysis of 8973 recordings in 7394 patients. Ann Noninvasive Electrocardiol. 2008 Jan;13(1):39-43. doi: 10.1111/j.1542-474X.2007.00199.x.

Reference Type BACKGROUND
PMID: 18234005 (View on PubMed)

Paudel B, Paudel K. The diagnostic significance of the holter monitoring in the evaluation of palpitation. J Clin Diagn Res. 2013 Mar;7(3):480-3. doi: 10.7860/JCDR/2013/4923.2802. Epub 2013 Mar 1.

Reference Type BACKGROUND
PMID: 23634400 (View on PubMed)

Hertzeanu H, Aron L. Holter monitoring for dizziness and syncope in old age. Acta Cardiol. 1985;40(3):291-9.

Reference Type BACKGROUND
PMID: 3875198 (View on PubMed)

Hennersdorf MG, Schueller PO, Steiner S, Strauer BE. Prevalence of paroxysmal atrial fibrillation depending on the regression of left ventricular hypertrophy in arterial hypertension. Hypertens Res. 2007 Jun;30(6):535-40. doi: 10.1291/hypres.30.535.

Reference Type BACKGROUND
PMID: 17664857 (View on PubMed)

Study Documents

Access uploaded study-related documents such as protocols, statistical analysis plans, or lay summaries.

Document Type: Study Protocol

In Danish language

View Document

Other Identifiers

Review additional registry numbers or institutional identifiers associated with this trial.

H-15006113

Identifier Type: -

Identifier Source: org_study_id

More Related Trials

Additional clinical trials that may be relevant based on similarity analysis.

Withings ECG-Monitor Study
NCT05316337 COMPLETED NA
Withings ECG-app Study
NCT05316350 COMPLETED NA