Validation Study of the Watch HWA09 and Its Softwares ECG-SW1 and PPG-SW1 for the Detection of Atrial Fibrillation
NCT ID: NCT04351386
Last Updated: 2021-11-16
Study Results
The study team has not published outcome measurements, participant flow, or safety data for this trial yet. Check back later for updates.
Basic Information
Get a concise snapshot of the trial, including recruitment status, study phase, enrollment targets, and key timeline milestones.
COMPLETED
283 participants
OBSERVATIONAL
2019-12-20
2021-04-07
Brief Summary
Review the sponsor-provided synopsis that highlights what the study is about and why it is being conducted.
Detailed Description
Dive into the extended narrative that explains the scientific background, objectives, and procedures in greater depth.
Primary objective :
To validate the diagnostic performance of the ECG-SW1 software integrated into the HWA09 watch for the automatic identification of atrial fibrillation (AF) compared to a simultaneous 12-lead ECG (hereinafter referred to as the "gold standard" or "reference method").
The algorithm classifies the watch signals into four categories: normal sinus rhythm (RSN), AF, arrhythmia other than AF, or non-interpretable. The latter category includes signals of insufficient quality to be interpreted with confidence.
This classification will be compared to the diagnosis made by three independent, blinded cardiologists based on a 12-lead ECG. The final diagnosis retained will be decided by majority with adjudication by a consensus of 3 to 6 cardiologists. The sensitivity and specificity of the device will then be estimated.
First secondary objectives:
The first secondary objective is to validate the diagnostic performance, compared to a simultaneous 12-lead ECG, of the PPG-SW1 software integrated in the HWA09 watch for the automatic identification of atrial fibrillation (AF) from the photoplethysmography (PPG) signal.
Three independent blinded cardiologists will issue a diagnosis based on the ECG recording of the HWA09 watch. The final diagnosis retained will be decided by majority with adjudication by a consensus of 3 to 6 cardiologists. Sensitivity and specificity will be calculated in relation to the reference ECG.
Second secondary objective:
To evaluate the quality of the single-channel strips measured with the HWA09 watch, as follows:
* Three independent cardiologists, having neither performed the data collection nor read the reference ECG, will independently make a diagnosis based on the HWA09 single-channel strips, blinded to the diagnosis made from the reference ECG. The ECG traces from the watch will be exported in PDF format from the Withings Health Mate application and the final diagnosis will be made by majority with adjudication by a consensus of 3 to 6 cardiologists. The final diagnosis will be compared to the diagnosis made by the cardiologists who read the reference ECG. Sensitivity and specificity will then be calculated.
* The visibility and polarity of ECG waves (i.e. P waves, QRS complex and T waves) will be determined by cardiologists for the single-channel strips recorded with HWA09 and for the lead I of the reference 12-lead ECG. For each of the waves, the agreement on their visibility and polarity (if visible) between the HWA09 and the reference ECG will be calculated.
* The durations of the major intervals of an ECG (i.e., QT interval, QRS complex, and PR interval) will be determined by the cardiologists for the single-channel strips recorded with HWA09 and for the lead I of the reference 12-lead ECG. For each interval (QT, QRS, PR), the difference of duration between the signals from the watch and the reference ECG will be calculated.
* The heart rate will first be determined by cardiologists from each signal of lead I (recorded by the HWA09 watch and the reference ECG) that has been diagnosed as NSR. The difference between the heart rate of the watch and the reference will be calculated. In a second step, the heart rate recorded by the HWA09 watch will be calculated by the Withings software. The difference between the heart rate calculated by the Withings software (from the signal of the watch) and the heart rate determined by the cardiologists (from the lead I of the reference ECG) will also be calculated.
The sponsor will ensure that no cardiologist makes a diagnosis on both a signal from the HWA09 watch and the reference ECG fomr the same patient. The sponsor will centralize diagnostics on the HWA09 and reference ECG signals and perform agreement calculations on the associated pairs.
Conditions
See the medical conditions and disease areas that this research is targeting or investigating.
Keywords
Explore important study keywords that can help with search, categorization, and topic discovery.
Study Design
Understand how the trial is structured, including allocation methods, masking strategies, primary purpose, and other design elements.
COHORT
PROSPECTIVE
Study Groups
Review each arm or cohort in the study, along with the interventions and objectives associated with them.
Atrial Fibrillation (AF)
Patients diagnosed with AF during reference ECG
AF Detection
Recording PPG and single-lead ECG signals with the Withings HWA09 and ECG signal for the reference 12-lead ECG
Normal Sinus Rhythm (NSR)
Patients with NSR during reference ECG
AF Detection
Recording PPG and single-lead ECG signals with the Withings HWA09 and ECG signal for the reference 12-lead ECG
Other Arrythmia
Patients diagnosed with an arrhythmia other than AF during the reference ECG
AF Detection
Recording PPG and single-lead ECG signals with the Withings HWA09 and ECG signal for the reference 12-lead ECG
Interventions
Learn about the drugs, procedures, or behavioral strategies being tested and how they are applied within this trial.
AF Detection
Recording PPG and single-lead ECG signals with the Withings HWA09 and ECG signal for the reference 12-lead ECG
Eligibility Criteria
Check the participation requirements, including inclusion and exclusion rules, age limits, and whether healthy volunteers are accepted.
Inclusion Criteria
* Individuals who expressed their non-opposition to take part in the study
* Individuals affiliated to a social security system or eligible
Exclusion Criteria
* Pregnant, parturient or breastfeeding women
* Individuals deprived of liberty by a court, medical or administrative order
* Individuals under 18yo
* Individuals legally protected or unable to express their non-opposition to take part in
* Individuals unaffiliated to or not beneficiary of a social security system
* Individuals who fit in multiple categories above
* Individuals having refused to take part in the study
* Individuals linguistically or mentally unable to express their non-opposition
* Individuals physically unable to wear a watch
* Individuals with an electrical pacing by a pacemaker
18 Years
ALL
No
Sponsors
Meet the organizations funding or collaborating on the study and learn about their roles.
Withings
INDUSTRY
Responsible Party
Identify the individual or organization who holds primary responsibility for the study information submitted to regulators.
Principal Investigators
Learn about the lead researchers overseeing the trial and their institutional affiliations.
David CAMPO
Role: STUDY_DIRECTOR
Withings
Julien NAHUM
Role: PRINCIPAL_INVESTIGATOR
Centre Cardiologique du Nord
Locations
Explore where the study is taking place and check the recruitment status at each participating site.
Institut Cœur Paris Centre Turin
Paris, Île-de-France Region, France
Hopital Europeen Georges Pompidou
Paris, Île-de-France Region, France
Centre Cardiologique du Nord
Saint-Denis, Île-de-France Region, France
Countries
Review the countries where the study has at least one active or historical site.
References
Explore related publications, articles, or registry entries linked to this study.
Campo D, Elie V, de Gallard T, Bartet P, Morichau-Beauchant T, Genain N, Fayol A, Fouassier D, Pasteur-Rousseau A, Puymirat E, Nahum J. Atrial Fibrillation Detection With an Analog Smartwatch: Prospective Clinical Study and Algorithm Validation. JMIR Form Res. 2022 Nov 4;6(11):e37280. doi: 10.2196/37280.
Other Identifiers
Review additional registry numbers or institutional identifiers associated with this trial.
2019-A01476-51
Identifier Type: -
Identifier Source: org_study_id