Anonymized Data Collection From the CS6BP for Heart Arrythmias Measurements

NCT ID: NCT05723744

Last Updated: 2023-02-13

Study Results

Results pending

The study team has not published outcome measurements, participant flow, or safety data for this trial yet. Check back later for updates.

Basic Information

Get a concise snapshot of the trial, including recruitment status, study phase, enrollment targets, and key timeline milestones.

Recruitment Status

COMPLETED

Clinical Phase

NA

Total Enrollment

47 participants

Study Classification

INTERVENTIONAL

Study Start Date

2020-11-27

Study Completion Date

2023-02-01

Brief Summary

Review the sponsor-provided synopsis that highlights what the study is about and why it is being conducted.

The purpose of this clinical study is to collect data simultaneously with the CS6BP watch sensors during EPS in order to characterize different evoked arrhythmias and record Blood Pressure during the procedures that blood pressure is collected by an automated cuff.

Detailed Description

Dive into the extended narrative that explains the scientific background, objectives, and procedures in greater depth.

The proposed clinical study is a Prospective Feasibility, Single-Center Study to collect data simultaneously with the CS6BP watch sensors during EPS or during admission in order to characterize different evoked arrhythmias. Subjects will be screened by the principal investigator or PI's delegate for meeting the study inclusion/exclusion criteria.

Subjects will be fitted with the CS6BP and ECG Holter by Investigator/Study Coordinator during the preparation of the subject to the procedure; when the subject is anesthetized and fitted with an automatic cuff that is preset to measure BP on a frequency as defined in the procedure protocol.

Subjects will be measured simultaneously with CardiacSense device, ECG Holter and EPS recording system if available (- ECG and intracardiac ECG recorded form intra-cardiac catheters). During the EPS the physician will timestamp and mark any provoked arrythmia either on ECG printouts or EPS recording system traces.

The device will be removed once patient has recovered. Subjects candidates for pacemaker implantation will be measured simultaneously with CardiacSense device and ECG Holter before procedure, during patient's hospitalization at cardiology division. At the end of the test the CardiacSense device and ECG Holter will be removed and their data will be downloaded. The recorded ECG (from Holter and if available also EPS recording/ mapping system) data will be analyzed by site staff. The analyzed ECG data will be sent to the company with the CS6BP raw data for further investigation.

BP values will be collected from subjects that are fitted with an automated cuff for BP monitoring for the purpose of evaluation and if required by the physician, during the hospitalization.

All adverse events (whether device related or not) will be reported during the course of the clinical study. All serious adverse events will be reported immediately to the study sponsor and monitor (within one working day). All clinical data will be recorded on appropriate CRFs.

Conditions

See the medical conditions and disease areas that this research is targeting or investigating.

Heart Arrythmias

Study Design

Understand how the trial is structured, including allocation methods, masking strategies, primary purpose, and other design elements.

Allocation Method

NA

Intervention Model

SINGLE_GROUP

The CS6BP includes a wrist-worn device with a clip connected to the band and is placed over the radial artery or a finger. The device includes a PPG sensor and is connected to ECG cables.
Primary Study Purpose

OTHER

Blinding Strategy

NONE

Open-label study

Study Groups

Review each arm or cohort in the study, along with the interventions and objectives associated with them.

CS6BP , ECG holter and Blood pressure measurements

The investigational device sensors tracings will be compared to the arrhythmia documented in all patients.

Group Type EXPERIMENTAL

ECG Holter and investigational device recordings for the purpose of developing Continuous Measurement of Heart Arrythmias

Intervention Type DEVICE

For Candidates for pacemaker implantation: ECG Holter and investigational device recordings (of PPG, ECG, and motion sensors tracings non-invasively) will be recorded before procedure, during patient's hospitalization at cardiology division. Blood pressure values that are collected by an automated cuff will be collected including any notes attached to the values.

All collected data will be analyzed offline

Interventions

Learn about the drugs, procedures, or behavioral strategies being tested and how they are applied within this trial.

ECG Holter and investigational device recordings for the purpose of developing Continuous Measurement of Heart Arrythmias

For Candidates for pacemaker implantation: ECG Holter and investigational device recordings (of PPG, ECG, and motion sensors tracings non-invasively) will be recorded before procedure, during patient's hospitalization at cardiology division. Blood pressure values that are collected by an automated cuff will be collected including any notes attached to the values.

All collected data will be analyzed offline

Intervention Type DEVICE

Eligibility Criteria

Check the participation requirements, including inclusion and exclusion rules, age limits, and whether healthy volunteers are accepted.

Inclusion Criteria

* Age of eighteen (18) year and above
* In clinical need for electrophysiology study (standalone or before ablation procedure) and/or Subjects with AVB who are candidates for pacemaker implantation
* Ability and willingness to sign an informed consent form

Exclusion Criteria

* Patients with significant co morbidities (assessed by the clinician at screening only):

Mechanically ventilated patients Mechanical circulation (LVAD, IABP, ECMO)

* Subjects who are currently enrolled in another clinical investigation in which the intervention might compromise the safety of the subject's participation in this study
* Subjects with PPG SNR \<100 indicated by the CS6BP device
* Women who are pregnant or breastfeeding
* Subjects with had deformity banning from wearing the device
Minimum Eligible Age

18 Years

Eligible Sex

ALL

Accepts Healthy Volunteers

No

Sponsors

Meet the organizations funding or collaborating on the study and learn about their roles.

CardiacSense Ltd.

INDUSTRY

Sponsor Role lead

Responsible Party

Identify the individual or organization who holds primary responsibility for the study information submitted to regulators.

Responsibility Role SPONSOR

Principal Investigators

Learn about the lead researchers overseeing the trial and their institutional affiliations.

Aharon Abbo, MD

Role: PRINCIPAL_INVESTIGATOR

Rambam Health Care Campus

Locations

Explore where the study is taking place and check the recruitment status at each participating site.

Rambam Medical Center

Haifa, , Israel

Site Status

Countries

Review the countries where the study has at least one active or historical site.

Israel

Other Identifiers

Review additional registry numbers or institutional identifiers associated with this trial.

CL00800

Identifier Type: -

Identifier Source: org_study_id

More Related Trials

Additional clinical trials that may be relevant based on similarity analysis.

ECG Validation Study
NCT05445726 ACTIVE_NOT_RECRUITING PHASE2
Cardiac Monitor Employee Study
NCT03826225 COMPLETED
Tempus Pro Monitor Registry
NCT05587764 COMPLETED
POTS Stroke Volume
NCT05796154 NOT_YET_RECRUITING NA