REmote CArdiac MOnitoring by the Corsano CardioWatch 287-2 Evaluation Study
NCT ID: NCT05899959
Last Updated: 2024-08-26
Study Results
The study team has not published outcome measurements, participant flow, or safety data for this trial yet. Check back later for updates.
Basic Information
Get a concise snapshot of the trial, including recruitment status, study phase, enrollment targets, and key timeline milestones.
COMPLETED
190 participants
OBSERVATIONAL
2023-06-15
2023-12-28
Brief Summary
Review the sponsor-provided synopsis that highlights what the study is about and why it is being conducted.
Two groups of patients are being recruited: patients receiving an EKG holter and patients receiving an automatic blood pressure monitor. Patients wear the wristband for 28 days. During this time, the number of atrial fibrillation episodes detected by the wristband is being counted, which is to be compared with the number of episodes detected by the holter. Also, blood pressure is measured continuously, which is to be compared with daily blood pressure measurements using a conventional blood pressure cuff.
Related Clinical Trials
Explore similar clinical trials based on study characteristics and research focus.
Validation of a Vital Signs Monitoring Wristband
NCT05566886
Clinical Data Validation of Novel Wireless Cortrium C3 Monitor for Continuous Electrocardiogram Measurements
NCT02714907
Exploratory Study of Apple Watch Electrocardiographic Diagnostic Performance Enhanced by an Artificial Intelligence Algorithm
NCT04792905
The Smartphone and Wearable Detected Atrial Arrhythmia in Older Adults Case Finding Study (Smart in OAC - AFNET 9)
NCT04579159
Automated Cardiac Arrest Detection and Alerting in Daily Life
NCT06692374
Detailed Description
Dive into the extended narrative that explains the scientific background, objectives, and procedures in greater depth.
Wearables have the potential to monitor patients remotely. The Corsano CardioWatch 287-2 is such a medical device that can monitor atrial fibrillation and long-term blood pressure. The device has been validated using clinical trials in hospitals, but validation in the intended remote setting is lacking.
Objective of the study:
Primary objective: To compare the number of episodes of atrial fibrillation detected by the Corsano CardioWatch 287-2 during 28 days of use with the number of episodes of atrial fibrillation detected by conventional Holter monitoring during 48 hours of use (standard care).
Secondary objective: To assess the difference in blood pressure measurements obtained by the Corsano CardioWatch 287-2 and the conventional cuff blood pressure monitor over a period of 28 days; to assess the usability of the Corsano CardioWatch 287-2 from a patient perspective.
Study design:
Group A:
Conventional 24 hour EKG holter monitoring will be compared to 28 day continuous monitoring by the Corsano CardioWatch 287-2 to assess whether the percentage of patients in whom atrial fibrillation is detected will increase. Detection of atrial fibrillation with the Corsano CardioWatch 287-2 is done by optical photoplethysmography (PPG), after which atrial fibrillation is confirmed with a 30-second ECG measurement.
Additionally, conventional cuff blood pressure will be compared to blood pressure measured by the Corsano CardioWatch 287-2 to validate free-living blood pressure monitoring. Patients will measure their blood pressure daily with a cuff blood pressure measurement device. The measurements at day 7, 14, 21 will be used to reinforce the Corsano blood pressure algorithm. The remaining measurements will be used to compare the blood pressure with the values measured by the Corsano CardioWatch 287-2 to assess accuracy.
Group B:
Conventional automatic cuff blood pressure measurement will be compared with the Corsano CardioWatch 287-2 for 24-48 hours. The automatic cuff blood pressure monitor will take a blood pressure reading every 30 minutes. Each reading will be compared with the Corsano CardioWatch 287-2 reading.
Study population:
Patients receiving a 24 hour EKG holter or an ambulant blood pressure device after visiting the cardiologist's outpatient clinic.
Primary study parameters/outcome of the study:
Absolute percentage increase of patients in whom at least one event of atrial fibrillation is detected by the Corsano CardioWatch 287-2 during 28 days of monitoring, compared to a conventional EKG holter during 24-48 hours of monitoring.
Secundary study parameters/outcome of the study (if applicable):
1. Mean blood pressure difference and its SD between blood pressure measured by the Corsano CardioWatch 287-2 and blood pressure measured by a conventional oscillometric blood pressure cuff.
2. Usability of the Corsano CardioWatch 287-2 in a remote care setting as determined by a questionnaire.
Nature and extent of the burden and risks associated with participation, benefit and group relatedness:
At the cardiologist's office, Group A and B patients receive 3 blood pressure measurements. These are performed by a nurse. Group A will take daily blood pressure readings of themselves at home. If atrial fibrillation is detected by the wristband, Group A patients will be asked to take an ECG. Finally, Group A patients will be asked once to complete a questionnaire. Group B only has to wear the wristband for 24 to 48 hours as an additional burden in addition to the aforementioned initial measurements.
Conditions
See the medical conditions and disease areas that this research is targeting or investigating.
Study Design
Understand how the trial is structured, including allocation methods, masking strategies, primary purpose, and other design elements.
COHORT
PROSPECTIVE
Study Groups
Review each arm or cohort in the study, along with the interventions and objectives associated with them.
Patients receiving an EKG holter
patients receiving an EKG holter at the outpatient clinic for 24-48 hours of remote monitoring
Corsano CardioWatch 287-2
Patients receive either an EKG holter or an automatic blood pressure cuff, as prescribed by their cardiologist. The readings from these devices (atrial fibrillation detection and blood pressure) will be compared to the readings from the CardioWatch 287-2.
Patients receiving an automatic blood pressure cuff
patients receiving an automatic blood pressure cuff at the outpatient clinic for 24 hours of remote monitoring
Corsano CardioWatch 287-2
Patients receive either an EKG holter or an automatic blood pressure cuff, as prescribed by their cardiologist. The readings from these devices (atrial fibrillation detection and blood pressure) will be compared to the readings from the CardioWatch 287-2.
Interventions
Learn about the drugs, procedures, or behavioral strategies being tested and how they are applied within this trial.
Corsano CardioWatch 287-2
Patients receive either an EKG holter or an automatic blood pressure cuff, as prescribed by their cardiologist. The readings from these devices (atrial fibrillation detection and blood pressure) will be compared to the readings from the CardioWatch 287-2.
Eligibility Criteria
Check the participation requirements, including inclusion and exclusion rules, age limits, and whether healthy volunteers are accepted.
Inclusion Criteria
* able to provide consent;
* receiving EKG holter or automatic blood pressure cuff for home monitoring per doctor prescription
Exclusion Criteria
* Unable to receive blood pressure measurements per cuff due to lymphedema, amputation, dialysis shunt, wounds, etc.;
* Pregnant women;
* Breastfeading women;
* Upper arm circumference not within the cuff range (22-42 cm)
* Unable or not willing to sign informed consent;
* Significant mental or cognitive impairment.
18 Years
ALL
No
Sponsors
Meet the organizations funding or collaborating on the study and learn about their roles.
Corsano Health B.V.
INDUSTRY
Responsible Party
Identify the individual or organization who holds primary responsibility for the study information submitted to regulators.
Locations
Explore where the study is taking place and check the recruitment status at each participating site.
Reinier de Graaf Gasthuis
Delft, South Holland, Netherlands
Countries
Review the countries where the study has at least one active or historical site.
References
Explore related publications, articles, or registry entries linked to this study.
van Vliet M, Aalberts JJJ, Hamelinck C, Hauer AD, Hoftijzer D, Monnink SHJ, Schipper JC, Constandse JC, Peters NS, Lip GYH, Steinhubl SR, Ronner E. Assessment of photoplethysmography-based blood pressure determinations during long-term and short-term remote cardiac monitoring: the RECAMO study. Eur Heart J Digit Health. 2025 Mar 27;6(4):763-771. doi: 10.1093/ehjdh/ztaf027. eCollection 2025 Jul.
van Vliet M, Aalberts JJJ, Hamelinck C, Hauer AD, Hoftijzer D, Monnink SHJ, Schipper JC, Constandse JC, Peters NS, Lip GYH, Steinhubl SR, Ronner E. Ambulatory atrial fibrillation detection and quantification by wristworn AI device compared to standard holter monitoring. NPJ Digit Med. 2025 Mar 25;8(1):177. doi: 10.1038/s41746-025-01555-9.
Other Identifiers
Review additional registry numbers or institutional identifiers associated with this trial.
RECAMO
Identifier Type: -
Identifier Source: org_study_id
More Related Trials
Additional clinical trials that may be relevant based on similarity analysis.