REmote CArdiac MOnitoring by the Corsano CardioWatch 287-2 Evaluation Study

NCT ID: NCT05899959

Last Updated: 2024-08-26

Study Results

Results pending

The study team has not published outcome measurements, participant flow, or safety data for this trial yet. Check back later for updates.

Basic Information

Get a concise snapshot of the trial, including recruitment status, study phase, enrollment targets, and key timeline milestones.

Recruitment Status

COMPLETED

Total Enrollment

190 participants

Study Classification

OBSERVATIONAL

Study Start Date

2023-06-15

Study Completion Date

2023-12-28

Brief Summary

Review the sponsor-provided synopsis that highlights what the study is about and why it is being conducted.

In this study, a wristband that monitors hearth rhythm and blood pressure is assessed in free living conditions.

Two groups of patients are being recruited: patients receiving an EKG holter and patients receiving an automatic blood pressure monitor. Patients wear the wristband for 28 days. During this time, the number of atrial fibrillation episodes detected by the wristband is being counted, which is to be compared with the number of episodes detected by the holter. Also, blood pressure is measured continuously, which is to be compared with daily blood pressure measurements using a conventional blood pressure cuff.

Detailed Description

Dive into the extended narrative that explains the scientific background, objectives, and procedures in greater depth.

Background of the study:

Wearables have the potential to monitor patients remotely. The Corsano CardioWatch 287-2 is such a medical device that can monitor atrial fibrillation and long-term blood pressure. The device has been validated using clinical trials in hospitals, but validation in the intended remote setting is lacking.

Objective of the study:

Primary objective: To compare the number of episodes of atrial fibrillation detected by the Corsano CardioWatch 287-2 during 28 days of use with the number of episodes of atrial fibrillation detected by conventional Holter monitoring during 48 hours of use (standard care).

Secondary objective: To assess the difference in blood pressure measurements obtained by the Corsano CardioWatch 287-2 and the conventional cuff blood pressure monitor over a period of 28 days; to assess the usability of the Corsano CardioWatch 287-2 from a patient perspective.

Study design:

Group A:

Conventional 24 hour EKG holter monitoring will be compared to 28 day continuous monitoring by the Corsano CardioWatch 287-2 to assess whether the percentage of patients in whom atrial fibrillation is detected will increase. Detection of atrial fibrillation with the Corsano CardioWatch 287-2 is done by optical photoplethysmography (PPG), after which atrial fibrillation is confirmed with a 30-second ECG measurement.

Additionally, conventional cuff blood pressure will be compared to blood pressure measured by the Corsano CardioWatch 287-2 to validate free-living blood pressure monitoring. Patients will measure their blood pressure daily with a cuff blood pressure measurement device. The measurements at day 7, 14, 21 will be used to reinforce the Corsano blood pressure algorithm. The remaining measurements will be used to compare the blood pressure with the values measured by the Corsano CardioWatch 287-2 to assess accuracy.

Group B:

Conventional automatic cuff blood pressure measurement will be compared with the Corsano CardioWatch 287-2 for 24-48 hours. The automatic cuff blood pressure monitor will take a blood pressure reading every 30 minutes. Each reading will be compared with the Corsano CardioWatch 287-2 reading.

Study population:

Patients receiving a 24 hour EKG holter or an ambulant blood pressure device after visiting the cardiologist's outpatient clinic.

Primary study parameters/outcome of the study:

Absolute percentage increase of patients in whom at least one event of atrial fibrillation is detected by the Corsano CardioWatch 287-2 during 28 days of monitoring, compared to a conventional EKG holter during 24-48 hours of monitoring.

Secundary study parameters/outcome of the study (if applicable):

1. Mean blood pressure difference and its SD between blood pressure measured by the Corsano CardioWatch 287-2 and blood pressure measured by a conventional oscillometric blood pressure cuff.
2. Usability of the Corsano CardioWatch 287-2 in a remote care setting as determined by a questionnaire.

Nature and extent of the burden and risks associated with participation, benefit and group relatedness:

At the cardiologist's office, Group A and B patients receive 3 blood pressure measurements. These are performed by a nurse. Group A will take daily blood pressure readings of themselves at home. If atrial fibrillation is detected by the wristband, Group A patients will be asked to take an ECG. Finally, Group A patients will be asked once to complete a questionnaire. Group B only has to wear the wristband for 24 to 48 hours as an additional burden in addition to the aforementioned initial measurements.

Conditions

See the medical conditions and disease areas that this research is targeting or investigating.

Atrial Fibrillation Rhythm; Disorder Palpitations Hypertension Hypotension

Study Design

Understand how the trial is structured, including allocation methods, masking strategies, primary purpose, and other design elements.

Observational Model Type

COHORT

Study Time Perspective

PROSPECTIVE

Study Groups

Review each arm or cohort in the study, along with the interventions and objectives associated with them.

Patients receiving an EKG holter

patients receiving an EKG holter at the outpatient clinic for 24-48 hours of remote monitoring

Corsano CardioWatch 287-2

Intervention Type DEVICE

Patients receive either an EKG holter or an automatic blood pressure cuff, as prescribed by their cardiologist. The readings from these devices (atrial fibrillation detection and blood pressure) will be compared to the readings from the CardioWatch 287-2.

Patients receiving an automatic blood pressure cuff

patients receiving an automatic blood pressure cuff at the outpatient clinic for 24 hours of remote monitoring

Corsano CardioWatch 287-2

Intervention Type DEVICE

Patients receive either an EKG holter or an automatic blood pressure cuff, as prescribed by their cardiologist. The readings from these devices (atrial fibrillation detection and blood pressure) will be compared to the readings from the CardioWatch 287-2.

Interventions

Learn about the drugs, procedures, or behavioral strategies being tested and how they are applied within this trial.

Corsano CardioWatch 287-2

Patients receive either an EKG holter or an automatic blood pressure cuff, as prescribed by their cardiologist. The readings from these devices (atrial fibrillation detection and blood pressure) will be compared to the readings from the CardioWatch 287-2.

Intervention Type DEVICE

Eligibility Criteria

Check the participation requirements, including inclusion and exclusion rules, age limits, and whether healthy volunteers are accepted.

Inclusion Criteria

* ≥ 18 years old;
* able to provide consent;
* receiving EKG holter or automatic blood pressure cuff for home monitoring per doctor prescription

Exclusion Criteria

* Unable to wear the Corsano CardioWatch 287 due to reasons such as allergic reactions, wounds, amputations etc.;
* Unable to receive blood pressure measurements per cuff due to lymphedema, amputation, dialysis shunt, wounds, etc.;
* Pregnant women;
* Breastfeading women;
* Upper arm circumference not within the cuff range (22-42 cm)
* Unable or not willing to sign informed consent;
* Significant mental or cognitive impairment.
Minimum Eligible Age

18 Years

Eligible Sex

ALL

Accepts Healthy Volunteers

No

Sponsors

Meet the organizations funding or collaborating on the study and learn about their roles.

Corsano Health B.V.

INDUSTRY

Sponsor Role lead

Responsible Party

Identify the individual or organization who holds primary responsibility for the study information submitted to regulators.

Responsibility Role SPONSOR

Locations

Explore where the study is taking place and check the recruitment status at each participating site.

Reinier de Graaf Gasthuis

Delft, South Holland, Netherlands

Site Status

Countries

Review the countries where the study has at least one active or historical site.

Netherlands

References

Explore related publications, articles, or registry entries linked to this study.

van Vliet M, Aalberts JJJ, Hamelinck C, Hauer AD, Hoftijzer D, Monnink SHJ, Schipper JC, Constandse JC, Peters NS, Lip GYH, Steinhubl SR, Ronner E. Assessment of photoplethysmography-based blood pressure determinations during long-term and short-term remote cardiac monitoring: the RECAMO study. Eur Heart J Digit Health. 2025 Mar 27;6(4):763-771. doi: 10.1093/ehjdh/ztaf027. eCollection 2025 Jul.

Reference Type DERIVED
PMID: 40703134 (View on PubMed)

van Vliet M, Aalberts JJJ, Hamelinck C, Hauer AD, Hoftijzer D, Monnink SHJ, Schipper JC, Constandse JC, Peters NS, Lip GYH, Steinhubl SR, Ronner E. Ambulatory atrial fibrillation detection and quantification by wristworn AI device compared to standard holter monitoring. NPJ Digit Med. 2025 Mar 25;8(1):177. doi: 10.1038/s41746-025-01555-9.

Reference Type DERIVED
PMID: 40133622 (View on PubMed)

Other Identifiers

Review additional registry numbers or institutional identifiers associated with this trial.

RECAMO

Identifier Type: -

Identifier Source: org_study_id

More Related Trials

Additional clinical trials that may be relevant based on similarity analysis.

Heart at Home- a Self-care Study
NCT01759368 COMPLETED NA
SmartWatch ECG Evaluation Trial I
NCT05942274 WITHDRAWN NA